对新手检查员拍摄的超声波图像进行直间距离测量的可靠性。

IF 1.6 4区 医学 Q2 REHABILITATION
Physiotherapy Theory and Practice Pub Date : 2024-11-01 Epub Date: 2023-09-11 DOI:10.1080/09593985.2023.2255897
Daria Chmielewska, Maciej Cebula, Rafał Gnat, Magdalena Rudek-Zeprzałka, Katarzyna Gruszczyńska, Jan Baron, Agnieszka Opala-Berdzik
{"title":"对新手检查员拍摄的超声波图像进行直间距离测量的可靠性。","authors":"Daria Chmielewska, Maciej Cebula, Rafał Gnat, Magdalena Rudek-Zeprzałka, Katarzyna Gruszczyńska, Jan Baron, Agnieszka Opala-Berdzik","doi":"10.1080/09593985.2023.2255897","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>With the increased interest in inter-recti distance measurement using ultrasound imaging in physiotherapy, there is a question of measurement reliability, and the importance of the examiner's experience.</p><p><strong>Purpose: </strong>The study aimed to investigate the reliability of inter-recti distance measurement in a DICOM viewer software by an experienced radiologist. For the measurement, the radiologist used linea alba images captured by two physiotherapists who were novice examiners.</p><p><strong>Methods: </strong>Ultrasound images were acquired by two novice examiners on repeated occasions 7 days apart (sessions A and B) in 28 nulliparous women at supraumbilical, umbilical, and infraumbilical locations along linea alba.</p><p><strong>Results: </strong>Excellent intra-examiner reliability of inter-recti distance measurements was shown at the supraumbilical and umbilical levels (ICC<sub>2,k</sub> = 0.941-0.983) with minimal detectable change (MDC<sub>95</sub>) ranging from 1.31 mm to 2.29 mm. Infraumbilical measurements had good to excellent reliability (ICC<sub>2,k</sub> = 0.894-0.972) with MDC<sub>95</sub> ranging from 0.33 mm to 0.72 mm. Session A inter-examiner reliability was excellent for the mean measurements of two, three, four, and five images taken at each location (ICC<sub>2,k</sub> = 0.913-0.954) with MDC<sub>95</sub> ranging from 0.47 mm to 2.96 mm. Session B inter-examiner reliability was excellent for the mean measurements of two, three, four, and five images taken at the supraumbilical and umbilical (ICC<sub>2,k</sub> = 0.94-0.98), MDC<sub>95</sub> ranging from 1.38 mm to 2.58 mm and good (ICC<sub>2,k</sub> ≥ 0.81) with MDC<sub>95</sub> ranging from 0.72 mm to 0.80 mm at the infraumbilical locations.</p><p><strong>Conclusion: </strong>Novice examiners were able to capture good-quality ultrasound images of the linea alba that allowed for good to excellent intra- and inter-examiner reliability.</p>","PeriodicalId":48699,"journal":{"name":"Physiotherapy Theory and Practice","volume":" ","pages":"2652-2660"},"PeriodicalIF":1.6000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Reliability of inter-recti distance measurement on ultrasound images captured by novice examiners.\",\"authors\":\"Daria Chmielewska, Maciej Cebula, Rafał Gnat, Magdalena Rudek-Zeprzałka, Katarzyna Gruszczyńska, Jan Baron, Agnieszka Opala-Berdzik\",\"doi\":\"10.1080/09593985.2023.2255897\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>With the increased interest in inter-recti distance measurement using ultrasound imaging in physiotherapy, there is a question of measurement reliability, and the importance of the examiner's experience.</p><p><strong>Purpose: </strong>The study aimed to investigate the reliability of inter-recti distance measurement in a DICOM viewer software by an experienced radiologist. For the measurement, the radiologist used linea alba images captured by two physiotherapists who were novice examiners.</p><p><strong>Methods: </strong>Ultrasound images were acquired by two novice examiners on repeated occasions 7 days apart (sessions A and B) in 28 nulliparous women at supraumbilical, umbilical, and infraumbilical locations along linea alba.</p><p><strong>Results: </strong>Excellent intra-examiner reliability of inter-recti distance measurements was shown at the supraumbilical and umbilical levels (ICC<sub>2,k</sub> = 0.941-0.983) with minimal detectable change (MDC<sub>95</sub>) ranging from 1.31 mm to 2.29 mm. Infraumbilical measurements had good to excellent reliability (ICC<sub>2,k</sub> = 0.894-0.972) with MDC<sub>95</sub> ranging from 0.33 mm to 0.72 mm. Session A inter-examiner reliability was excellent for the mean measurements of two, three, four, and five images taken at each location (ICC<sub>2,k</sub> = 0.913-0.954) with MDC<sub>95</sub> ranging from 0.47 mm to 2.96 mm. Session B inter-examiner reliability was excellent for the mean measurements of two, three, four, and five images taken at the supraumbilical and umbilical (ICC<sub>2,k</sub> = 0.94-0.98), MDC<sub>95</sub> ranging from 1.38 mm to 2.58 mm and good (ICC<sub>2,k</sub> ≥ 0.81) with MDC<sub>95</sub> ranging from 0.72 mm to 0.80 mm at the infraumbilical locations.</p><p><strong>Conclusion: </strong>Novice examiners were able to capture good-quality ultrasound images of the linea alba that allowed for good to excellent intra- and inter-examiner reliability.</p>\",\"PeriodicalId\":48699,\"journal\":{\"name\":\"Physiotherapy Theory and Practice\",\"volume\":\" \",\"pages\":\"2652-2660\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Physiotherapy Theory and Practice\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/09593985.2023.2255897\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/9/11 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"REHABILITATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physiotherapy Theory and Practice","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/09593985.2023.2255897","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/9/11 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"REHABILITATION","Score":null,"Total":0}
引用次数: 0

摘要

背景:目的:本研究旨在调查一位经验丰富的放射科医生在 DICOM 查看器软件中进行直间距离测量的可靠性。在测量过程中,放射科医生使用了由两名新手物理治疗师采集的白线图像:方法:由两名新手检查员在相隔 7 天的重复场合(A 和 B 次)采集 28 名无产科妇女的脐上、脐部和脐下沿白线位置的超声波图像:脐上和脐下的直间距测量结果显示出极佳的检查者内部可靠性(ICC2,k = 0.941-0.983),最小可检测变化(MDC95)范围为 1.31 毫米至 2.29 毫米。脐下测量的可靠性从良好到极佳(ICC2,k = 0.894-0.972),MDC95 在 0.33 毫米到 0.72 毫米之间。A 次检查中,每个位置的两张、三张、四张和五张图像的平均测量值的检查者间可靠性极佳(ICC2,k = 0.913-0.954),MDC95 范围为 0.47 毫米至 2.96 毫米。在脐上和脐下拍摄的两张、三张、四张和五张图像的平均测量值(ICC2,k = 0.94-0.98),MDC95 的范围为 1.38 毫米至 2.58 毫米;在脐下位置拍摄的两张、三张、四张和五张图像的平均测量值(ICC2,k ≥ 0.81),MDC95 的范围为 0.72 毫米至 0.80 毫米:结论:新手检查者能够捕捉到高质量的白线超声图像,检查者内部和检查者之间的可靠性良好甚至极佳。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Reliability of inter-recti distance measurement on ultrasound images captured by novice examiners.

Background: With the increased interest in inter-recti distance measurement using ultrasound imaging in physiotherapy, there is a question of measurement reliability, and the importance of the examiner's experience.

Purpose: The study aimed to investigate the reliability of inter-recti distance measurement in a DICOM viewer software by an experienced radiologist. For the measurement, the radiologist used linea alba images captured by two physiotherapists who were novice examiners.

Methods: Ultrasound images were acquired by two novice examiners on repeated occasions 7 days apart (sessions A and B) in 28 nulliparous women at supraumbilical, umbilical, and infraumbilical locations along linea alba.

Results: Excellent intra-examiner reliability of inter-recti distance measurements was shown at the supraumbilical and umbilical levels (ICC2,k = 0.941-0.983) with minimal detectable change (MDC95) ranging from 1.31 mm to 2.29 mm. Infraumbilical measurements had good to excellent reliability (ICC2,k = 0.894-0.972) with MDC95 ranging from 0.33 mm to 0.72 mm. Session A inter-examiner reliability was excellent for the mean measurements of two, three, four, and five images taken at each location (ICC2,k = 0.913-0.954) with MDC95 ranging from 0.47 mm to 2.96 mm. Session B inter-examiner reliability was excellent for the mean measurements of two, three, four, and five images taken at the supraumbilical and umbilical (ICC2,k = 0.94-0.98), MDC95 ranging from 1.38 mm to 2.58 mm and good (ICC2,k ≥ 0.81) with MDC95 ranging from 0.72 mm to 0.80 mm at the infraumbilical locations.

Conclusion: Novice examiners were able to capture good-quality ultrasound images of the linea alba that allowed for good to excellent intra- and inter-examiner reliability.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.40
自引率
10.00%
发文量
300
期刊介绍: The aim of Physiotherapy Theory and Practice is to provide an international, peer-reviewed forum for the publication, dissemination, and discussion of recent developments and current research in physiotherapy/physical therapy. The journal accepts original quantitative and qualitative research reports, theoretical papers, systematic literature reviews, clinical case reports, and technical clinical notes. Physiotherapy Theory and Practice; promotes post-basic education through reports, reviews, and updates on all aspects of physiotherapy and specialties relating to clinical physiotherapy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信