{"title":"奥祖德克斯植入物前移的风险因素和并发症回顾:从以往报告中汲取的教训","authors":"Hui Gim Khor, Pooi Wah Lott, Azida Juana Wan Ab Kadir, Sujaya Singh, Tajunisah Iqbal","doi":"10.1089/jop.2023.0012","DOIUrl":null,"url":null,"abstract":"<p><p><b><i>Purpose:</i></b> Ozurdex had shown promising anatomical and functional outcomes in managing refractory Irvine-Gass syndrome over the years. Burgeoning usage of Ozurdex has prompted the study of its related complications, particularly the anterior chamber migration of the implant. <b><i>Methods:</i></b> Literature reviews on the anterior chamber migration of the Ozurdex via PubMed, EBSCO, and TRIP databases were searched from 2012 to 2020. The predisposing factors, outcomes, and management of such cases were evaluated. <b><i>Results:</i></b> A total of 54 articles consisting of 105 cases of anterior migration of Ozurdex were included in this analysis. The vitrectomized eye and compromised posterior capsule were highly associated with this complication. About 81.9% of the cases had cornea edema upon presentation, with 31.4% of them ending up with cornea decompensation despite intervention. Although there was high intraocular pressure reported initially in 22 cases, only 2 cases required glaucoma filtration surgeries in which they had preexisting glaucoma. Numerous techniques of repositioning or surgical removal of the implant were described but they were challenging and the outcomes varied. <b><i>Conclusions:</i></b> A noninvasive method of manipulating the Ozurdex into the vitreous cavity via the \"Trendelenburg position, external pressure with head positioning\" maneuvers is safe yet achieves a favorable outcome. Precaution must be taken whenever offering Ozurdex to the high-risk eyes. Prompt repositioning or removal of the implant is crucial to deter cornea decompensation. Clinical Trial Registration number: NMRR-22-02092-S9X (from the Medical Research and Ethics Committee (MREC), Ministry of Health, Malaysia).</p>","PeriodicalId":16689,"journal":{"name":"Journal of Ocular Pharmacology and Therapeutics","volume":" ","pages":"342-360"},"PeriodicalIF":1.9000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Review of Risk Factors and Complications of Anterior Migration of Ozurdex Implant: Lessons Learnt from the Previous Reports.\",\"authors\":\"Hui Gim Khor, Pooi Wah Lott, Azida Juana Wan Ab Kadir, Sujaya Singh, Tajunisah Iqbal\",\"doi\":\"10.1089/jop.2023.0012\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b><i>Purpose:</i></b> Ozurdex had shown promising anatomical and functional outcomes in managing refractory Irvine-Gass syndrome over the years. Burgeoning usage of Ozurdex has prompted the study of its related complications, particularly the anterior chamber migration of the implant. <b><i>Methods:</i></b> Literature reviews on the anterior chamber migration of the Ozurdex via PubMed, EBSCO, and TRIP databases were searched from 2012 to 2020. The predisposing factors, outcomes, and management of such cases were evaluated. <b><i>Results:</i></b> A total of 54 articles consisting of 105 cases of anterior migration of Ozurdex were included in this analysis. The vitrectomized eye and compromised posterior capsule were highly associated with this complication. About 81.9% of the cases had cornea edema upon presentation, with 31.4% of them ending up with cornea decompensation despite intervention. Although there was high intraocular pressure reported initially in 22 cases, only 2 cases required glaucoma filtration surgeries in which they had preexisting glaucoma. Numerous techniques of repositioning or surgical removal of the implant were described but they were challenging and the outcomes varied. <b><i>Conclusions:</i></b> A noninvasive method of manipulating the Ozurdex into the vitreous cavity via the \\\"Trendelenburg position, external pressure with head positioning\\\" maneuvers is safe yet achieves a favorable outcome. Precaution must be taken whenever offering Ozurdex to the high-risk eyes. Prompt repositioning or removal of the implant is crucial to deter cornea decompensation. Clinical Trial Registration number: NMRR-22-02092-S9X (from the Medical Research and Ethics Committee (MREC), Ministry of Health, Malaysia).</p>\",\"PeriodicalId\":16689,\"journal\":{\"name\":\"Journal of Ocular Pharmacology and Therapeutics\",\"volume\":\" \",\"pages\":\"342-360\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Ocular Pharmacology and Therapeutics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1089/jop.2023.0012\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/9/7 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ocular Pharmacology and Therapeutics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1089/jop.2023.0012","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/9/7 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:多年来,Ozurdex 在治疗难治性欧文-加斯综合征方面取得了良好的解剖和功能效果。随着 Ozurdex 使用量的激增,人们开始研究其相关并发症,尤其是植入物的前房移位。方法:通过PubMed、EBSCO和TRIP数据库检索了2012年至2020年有关Ozurdex前房移位的文献综述。评估了此类病例的诱发因素、结果和处理方法。结果:本分析共纳入了54篇文章,包括105例Ozurdex前移病例。玻璃体切割眼和受损的后囊与这种并发症密切相关。约81.9%的病例在发病时出现角膜水肿,其中31.4%的病例在接受干预后仍出现角膜失代偿。虽然有 22 例病例最初报告眼压较高,但只有 2 例病例需要进行青光眼滤过手术,而这 2 例病例之前就患有青光眼。对重新定位或手术移除植入物的许多技术进行了描述,但这些技术都具有挑战性,而且结果也各不相同。结论:通过 "Trendelenburg 体位、头部定位外压 "操作将 Ozurdex 植入玻璃体腔的无创方法既安全又能取得良好的效果。在为高危眼球提供 Ozurdex 时必须小心谨慎。及时调整植入物的位置或取出植入物对于防止角膜失代偿至关重要。临床试验注册号NMRR-22-02092-S9X(马来西亚卫生部医学研究与伦理委员会 (MREC))。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Review of Risk Factors and Complications of Anterior Migration of Ozurdex Implant: Lessons Learnt from the Previous Reports.

Purpose: Ozurdex had shown promising anatomical and functional outcomes in managing refractory Irvine-Gass syndrome over the years. Burgeoning usage of Ozurdex has prompted the study of its related complications, particularly the anterior chamber migration of the implant. Methods: Literature reviews on the anterior chamber migration of the Ozurdex via PubMed, EBSCO, and TRIP databases were searched from 2012 to 2020. The predisposing factors, outcomes, and management of such cases were evaluated. Results: A total of 54 articles consisting of 105 cases of anterior migration of Ozurdex were included in this analysis. The vitrectomized eye and compromised posterior capsule were highly associated with this complication. About 81.9% of the cases had cornea edema upon presentation, with 31.4% of them ending up with cornea decompensation despite intervention. Although there was high intraocular pressure reported initially in 22 cases, only 2 cases required glaucoma filtration surgeries in which they had preexisting glaucoma. Numerous techniques of repositioning or surgical removal of the implant were described but they were challenging and the outcomes varied. Conclusions: A noninvasive method of manipulating the Ozurdex into the vitreous cavity via the "Trendelenburg position, external pressure with head positioning" maneuvers is safe yet achieves a favorable outcome. Precaution must be taken whenever offering Ozurdex to the high-risk eyes. Prompt repositioning or removal of the implant is crucial to deter cornea decompensation. Clinical Trial Registration number: NMRR-22-02092-S9X (from the Medical Research and Ethics Committee (MREC), Ministry of Health, Malaysia).

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.60
自引率
4.30%
发文量
72
审稿时长
1 months
期刊介绍: Journal of Ocular Pharmacology and Therapeutics is the only peer-reviewed journal that combines the fields of ophthalmology and pharmacology to enable optimal treatment and prevention of ocular diseases and disorders. The Journal delivers the latest discoveries in the pharmacokinetics and pharmacodynamics of therapeutics for the treatment of ophthalmic disorders. Journal of Ocular Pharmacology and Therapeutics coverage includes: Glaucoma Cataracts Retinal degeneration Ocular infection, trauma, and toxicology Ocular drug delivery and biotransformation Ocular pharmacotherapy/clinical trials Ocular inflammatory and immune disorders Gene and cell-based therapies Ocular metabolic disorders Ocular ischemia and blood flow Proliferative disorders of the eye Eyes on Drug Discovery - written by Gary D. Novack, PhD, featuring the latest updates on drug and device pipeline developments as well as policy/regulatory changes by the FDA.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信