Franz Endstrasser, Richard A Lindtner, Anna Landegger, Moritz Wagner, Martin Eichinger, Hannes Schönthaler, Gerhard Kaufmann, Alexander Brunner
{"title":"AAA踝关节置换术的中期疗效。","authors":"Franz Endstrasser, Richard A Lindtner, Anna Landegger, Moritz Wagner, Martin Eichinger, Hannes Schönthaler, Gerhard Kaufmann, Alexander Brunner","doi":"10.1177/10711007231186375","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Outcome reports for Alpha Ankle Arthroplasty (AAA), a third-generation implant relying on a mobile bearing design for total ankle replacement, are sparse. This retrospective study evaluated the midterm survivorship, clinical, and radiologic outcomes after implantation of this implant.</p><p><strong>Methods: </strong>For 64 patients who received 65 Triple A ankle implants between 2009 and 2020, implant survival was calculated using the Kaplan-Meier curve. Clinical outcomes were evaluated by measuring the range of motion, stability, Western Ontario and McMaster Universities Osteoarthritis Questionnaire score (WOMAC), and American Orthopaedic Foot & Ankle Society ankle-hindfoot score (AOFAS). The average pain level and satisfaction with the postoperative result were rated on a numeric rating scale (0-10). Additionally, radiologic analysis was performed using anteroposterior and lateral radiographs and tibiotalar alignment was assessed.</p><p><strong>Results: </strong>The implant-survival rate was 61.5% at a mean follow-up of 8.2 years. Twenty-five patients (38.5%) required revision surgery (average time to revision, 3.1 years, 95% CI 2.1-4.1 years). For patients without revisions, the average range of motion in dorsiflexion and plantarflexion were 3.6 ± 4.2 degrees and 21.9 ± 7.8 degrees, respectively. The mean WOMAC and AOFAS scores were 44.7 ± 47.5 and 75.1 ± 14.0, respectively. The average pain and subjective satisfaction scores were 2.0 ± 1.7 and 8.5 ± 1.9, respectively. Mean alignment values did not differ significantly for patients who required revision surgery.</p><p><strong>Conclusion: </strong>We found a high revision rate with use of the AAA. However, patients who did not require revision surgery had, on average, high satisfaction and good functional outcomes.</p><p><strong>Level of evidence: </strong>Level IV, case series.</p>","PeriodicalId":12446,"journal":{"name":"Foot & Ankle International","volume":" ","pages":"983-991"},"PeriodicalIF":2.4000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Midterm Results of AAA Ankle Arthroplasty.\",\"authors\":\"Franz Endstrasser, Richard A Lindtner, Anna Landegger, Moritz Wagner, Martin Eichinger, Hannes Schönthaler, Gerhard Kaufmann, Alexander Brunner\",\"doi\":\"10.1177/10711007231186375\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Outcome reports for Alpha Ankle Arthroplasty (AAA), a third-generation implant relying on a mobile bearing design for total ankle replacement, are sparse. This retrospective study evaluated the midterm survivorship, clinical, and radiologic outcomes after implantation of this implant.</p><p><strong>Methods: </strong>For 64 patients who received 65 Triple A ankle implants between 2009 and 2020, implant survival was calculated using the Kaplan-Meier curve. Clinical outcomes were evaluated by measuring the range of motion, stability, Western Ontario and McMaster Universities Osteoarthritis Questionnaire score (WOMAC), and American Orthopaedic Foot & Ankle Society ankle-hindfoot score (AOFAS). The average pain level and satisfaction with the postoperative result were rated on a numeric rating scale (0-10). Additionally, radiologic analysis was performed using anteroposterior and lateral radiographs and tibiotalar alignment was assessed.</p><p><strong>Results: </strong>The implant-survival rate was 61.5% at a mean follow-up of 8.2 years. Twenty-five patients (38.5%) required revision surgery (average time to revision, 3.1 years, 95% CI 2.1-4.1 years). For patients without revisions, the average range of motion in dorsiflexion and plantarflexion were 3.6 ± 4.2 degrees and 21.9 ± 7.8 degrees, respectively. The mean WOMAC and AOFAS scores were 44.7 ± 47.5 and 75.1 ± 14.0, respectively. The average pain and subjective satisfaction scores were 2.0 ± 1.7 and 8.5 ± 1.9, respectively. Mean alignment values did not differ significantly for patients who required revision surgery.</p><p><strong>Conclusion: </strong>We found a high revision rate with use of the AAA. However, patients who did not require revision surgery had, on average, high satisfaction and good functional outcomes.</p><p><strong>Level of evidence: </strong>Level IV, case series.</p>\",\"PeriodicalId\":12446,\"journal\":{\"name\":\"Foot & Ankle International\",\"volume\":\" \",\"pages\":\"983-991\"},\"PeriodicalIF\":2.4000,\"publicationDate\":\"2023-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Foot & Ankle International\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/10711007231186375\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/9/1 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Foot & Ankle International","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/10711007231186375","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/9/1 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
Background: Outcome reports for Alpha Ankle Arthroplasty (AAA), a third-generation implant relying on a mobile bearing design for total ankle replacement, are sparse. This retrospective study evaluated the midterm survivorship, clinical, and radiologic outcomes after implantation of this implant.
Methods: For 64 patients who received 65 Triple A ankle implants between 2009 and 2020, implant survival was calculated using the Kaplan-Meier curve. Clinical outcomes were evaluated by measuring the range of motion, stability, Western Ontario and McMaster Universities Osteoarthritis Questionnaire score (WOMAC), and American Orthopaedic Foot & Ankle Society ankle-hindfoot score (AOFAS). The average pain level and satisfaction with the postoperative result were rated on a numeric rating scale (0-10). Additionally, radiologic analysis was performed using anteroposterior and lateral radiographs and tibiotalar alignment was assessed.
Results: The implant-survival rate was 61.5% at a mean follow-up of 8.2 years. Twenty-five patients (38.5%) required revision surgery (average time to revision, 3.1 years, 95% CI 2.1-4.1 years). For patients without revisions, the average range of motion in dorsiflexion and plantarflexion were 3.6 ± 4.2 degrees and 21.9 ± 7.8 degrees, respectively. The mean WOMAC and AOFAS scores were 44.7 ± 47.5 and 75.1 ± 14.0, respectively. The average pain and subjective satisfaction scores were 2.0 ± 1.7 and 8.5 ± 1.9, respectively. Mean alignment values did not differ significantly for patients who required revision surgery.
Conclusion: We found a high revision rate with use of the AAA. However, patients who did not require revision surgery had, on average, high satisfaction and good functional outcomes.
期刊介绍:
Foot & Ankle International (FAI), in publication since 1980, is the official journal of the American Orthopaedic Foot & Ankle Society (AOFAS). This monthly medical journal emphasizes surgical and medical management as it relates to the foot and ankle with a specific focus on reconstructive, trauma, and sports-related conditions utilizing the latest technological advances. FAI offers original, clinically oriented, peer-reviewed research articles presenting new approaches to foot and ankle pathology and treatment, current case reviews, and technique tips addressing the management of complex problems. This journal is an ideal resource for highly-trained orthopaedic foot and ankle specialists and allied health care providers.
The journal’s Founding Editor, Melvin H. Jahss, MD (deceased), served from 1980-1988. He was followed by Kenneth A. Johnson, MD (deceased) from 1988-1993; Lowell D. Lutter, MD (deceased) from 1993-2004; and E. Greer Richardson, MD from 2005-2007. David B. Thordarson, MD, assumed the role of Editor-in-Chief in 2008.
The journal focuses on the following areas of interest:
• Surgery
• Wound care
• Bone healing
• Pain management
• In-office orthotic systems
• Diabetes
• Sports medicine