Elise Schlissel Tremblay, Kate Millington, Yunhong Wu, David Wypij, Yufan Yang, Michael S D Agus, Joseph Wolfsdorf
{"title":"血浆β -羟基丁酸测定糖尿病酮症酸中毒的疗效。","authors":"Elise Schlissel Tremblay, Kate Millington, Yunhong Wu, David Wypij, Yufan Yang, Michael S D Agus, Joseph Wolfsdorf","doi":"10.1111/pedi.13437","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Diabetic ketoacidosis (DKA) is a common, life-threatening complication of type 1 diabetes (T1D) characterized by unregulated ketogenesis caused by relative or absolute insulin deficiency. DKA management requires frequent biochemical monitoring. Plasma ß-hydroxybutyrate (BOHB) has not been included in traditional definitions of DKA resolution.</p><p><strong>Objective: </strong>The aim of this study was to determine a cut-point level of BOHB to define DKA resolution in patients with T1D treated with intravenous (IV) insulin.</p><p><strong>Subjects: </strong>We identified patients with T1D receiving IV insulin for DKA treatment at a quaternary children's hospital from January 1, 2017 through December 31, 2020 who had plasma measurements of BOHB after DKA onset and whose DKA resolved by traditional laboratory criteria (venous pH (vpH) ≥ 7.3, serum bicarbonate (HCO<sub>3</sub> ) ≥ 15 mmol/L, and/or anion gap (AG) ≤ 14 mmol/L).</p><p><strong>Methods: </strong>Associations between plasma BOHB and vpH, HCO<sub>3</sub> , and AG were evaluated via scatterplots. Receiver operating characteristic (ROC) curves and area under the curve (AUC) were used to evaluate BOHB cut-points to predict DKA resolution.</p><p><strong>Results: </strong>We analyzed 403 patients with 471 unique encounters. Plasma BOHB showed the most robust relationship with AG. The ROC curve comparing plasma BOHB to the accepted definition of DKA resolution, AG ≤14 mmol/L, had an AUC of 0.92. A BOHB value of <1.5 mmol/L had a sensitivity of 83% and specificity of 87%; this cut-point correctly classified 86% of the observations.</p><p><strong>Conclusions: </strong>A plasma BOHB value of <1.5 mmol/L can be used to define resolution of DKA.</p>","PeriodicalId":3,"journal":{"name":"ACS Applied Electronic Materials","volume":null,"pages":null},"PeriodicalIF":4.3000,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9772128/pdf/","citationCount":"1","resultStr":"{\"title\":\"Utility of plasma beta-hydroxybutyrate to define resolution of diabetic ketoacidosis.\",\"authors\":\"Elise Schlissel Tremblay, Kate Millington, Yunhong Wu, David Wypij, Yufan Yang, Michael S D Agus, Joseph Wolfsdorf\",\"doi\":\"10.1111/pedi.13437\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Diabetic ketoacidosis (DKA) is a common, life-threatening complication of type 1 diabetes (T1D) characterized by unregulated ketogenesis caused by relative or absolute insulin deficiency. DKA management requires frequent biochemical monitoring. Plasma ß-hydroxybutyrate (BOHB) has not been included in traditional definitions of DKA resolution.</p><p><strong>Objective: </strong>The aim of this study was to determine a cut-point level of BOHB to define DKA resolution in patients with T1D treated with intravenous (IV) insulin.</p><p><strong>Subjects: </strong>We identified patients with T1D receiving IV insulin for DKA treatment at a quaternary children's hospital from January 1, 2017 through December 31, 2020 who had plasma measurements of BOHB after DKA onset and whose DKA resolved by traditional laboratory criteria (venous pH (vpH) ≥ 7.3, serum bicarbonate (HCO<sub>3</sub> ) ≥ 15 mmol/L, and/or anion gap (AG) ≤ 14 mmol/L).</p><p><strong>Methods: </strong>Associations between plasma BOHB and vpH, HCO<sub>3</sub> , and AG were evaluated via scatterplots. Receiver operating characteristic (ROC) curves and area under the curve (AUC) were used to evaluate BOHB cut-points to predict DKA resolution.</p><p><strong>Results: </strong>We analyzed 403 patients with 471 unique encounters. Plasma BOHB showed the most robust relationship with AG. The ROC curve comparing plasma BOHB to the accepted definition of DKA resolution, AG ≤14 mmol/L, had an AUC of 0.92. A BOHB value of <1.5 mmol/L had a sensitivity of 83% and specificity of 87%; this cut-point correctly classified 86% of the observations.</p><p><strong>Conclusions: </strong>A plasma BOHB value of <1.5 mmol/L can be used to define resolution of DKA.</p>\",\"PeriodicalId\":3,\"journal\":{\"name\":\"ACS Applied Electronic Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.3000,\"publicationDate\":\"2022-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9772128/pdf/\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Electronic Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/pedi.13437\",\"RegionNum\":3,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/10/29 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Electronic Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/pedi.13437","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/10/29 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
Utility of plasma beta-hydroxybutyrate to define resolution of diabetic ketoacidosis.
Background: Diabetic ketoacidosis (DKA) is a common, life-threatening complication of type 1 diabetes (T1D) characterized by unregulated ketogenesis caused by relative or absolute insulin deficiency. DKA management requires frequent biochemical monitoring. Plasma ß-hydroxybutyrate (BOHB) has not been included in traditional definitions of DKA resolution.
Objective: The aim of this study was to determine a cut-point level of BOHB to define DKA resolution in patients with T1D treated with intravenous (IV) insulin.
Subjects: We identified patients with T1D receiving IV insulin for DKA treatment at a quaternary children's hospital from January 1, 2017 through December 31, 2020 who had plasma measurements of BOHB after DKA onset and whose DKA resolved by traditional laboratory criteria (venous pH (vpH) ≥ 7.3, serum bicarbonate (HCO3 ) ≥ 15 mmol/L, and/or anion gap (AG) ≤ 14 mmol/L).
Methods: Associations between plasma BOHB and vpH, HCO3 , and AG were evaluated via scatterplots. Receiver operating characteristic (ROC) curves and area under the curve (AUC) were used to evaluate BOHB cut-points to predict DKA resolution.
Results: We analyzed 403 patients with 471 unique encounters. Plasma BOHB showed the most robust relationship with AG. The ROC curve comparing plasma BOHB to the accepted definition of DKA resolution, AG ≤14 mmol/L, had an AUC of 0.92. A BOHB value of <1.5 mmol/L had a sensitivity of 83% and specificity of 87%; this cut-point correctly classified 86% of the observations.
Conclusions: A plasma BOHB value of <1.5 mmol/L can be used to define resolution of DKA.