{"title":"长段阻断螺钉能否增加胫骨近端骨折髓内钉固定的稳定性,消除 \"钟罩效应\"?","authors":"Derek S Stenquist, Meghan McCaskey, Miguel Diaz, Steven D Munassi, Giovanni Ayala, David Donohue, Hassan R Mir","doi":"10.1097/BOT.0000000000002683","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To determine change in stiffness and horizontal translation of a geriatric extra-articular proximal tibia fracture model after intramedullary nailing with distal (long)-segment blocking screws versus proximal (short)-segment blocking screws.</p><p><strong>Methods: </strong>Unstable extra-articular proximal tibia fractures (OTA/AO 41-A3) were created in 12 geriatric cadaveric tibias. Intramedullary nails were locked with a standard construct (4 proximal screws and 2 distal screws). Specimens were then divided into 2 groups (6 matched pairs per group). Group 1 had a blocking screw placed lateral to the nail in the proximal segment (short segment). Group 2 had a blocking screw placed 1 cm distal to the fracture and medial to the nail (long segment). Specimens were then axially loaded and cycled to failure or cycle completion (50,000 cycles).</p><p><strong>Results: </strong>Long-segment blocking screws significantly decreased the amount of horizontal translation at the fracture site compared with short-segment screws (0.77 vs. 2.0 mm, P = 0.039). They also resulted in a greater trend towards greater baseline stiffness, (807.32 ± 216.95 N/mm vs. 583.12 ± 130.1 N/mm, P = 0.072). There was no difference in stiffness after cyclic loading or survival through 50,000 cycles between the long-segment and short-segment groups.</p><p><strong>Conclusion: </strong>Long-segment blocking screws added to an intramedullary nail construct resulted in decreased horizontal translation at the fracture site compared with short-segment screws in this model of a geriatric proximal tibia fracture.</p><p><strong>Clinical relevance: </strong>Blocking screws are commonly used to aid in fracture alignment during intramedullary nailing of proximal tibia fractures. Even when not required to attain or maintain alignment, the addition of a blocking screw in either the proximal or the distal (long) segment may help mitigate the \"Bell-Clapper Effect\" in geriatric patients.</p>","PeriodicalId":16644,"journal":{"name":"Journal of Orthopaedic Trauma","volume":" ","pages":"e4-e8"},"PeriodicalIF":1.6000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Do Long-Segment Blocking Screws Increase the Stability of Intramedullary Nail Fixation in Proximal Tibia Fractures, Eliminating the \\\"Bell-Clapper Effect?\\\"\",\"authors\":\"Derek S Stenquist, Meghan McCaskey, Miguel Diaz, Steven D Munassi, Giovanni Ayala, David Donohue, Hassan R Mir\",\"doi\":\"10.1097/BOT.0000000000002683\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>To determine change in stiffness and horizontal translation of a geriatric extra-articular proximal tibia fracture model after intramedullary nailing with distal (long)-segment blocking screws versus proximal (short)-segment blocking screws.</p><p><strong>Methods: </strong>Unstable extra-articular proximal tibia fractures (OTA/AO 41-A3) were created in 12 geriatric cadaveric tibias. Intramedullary nails were locked with a standard construct (4 proximal screws and 2 distal screws). Specimens were then divided into 2 groups (6 matched pairs per group). Group 1 had a blocking screw placed lateral to the nail in the proximal segment (short segment). Group 2 had a blocking screw placed 1 cm distal to the fracture and medial to the nail (long segment). Specimens were then axially loaded and cycled to failure or cycle completion (50,000 cycles).</p><p><strong>Results: </strong>Long-segment blocking screws significantly decreased the amount of horizontal translation at the fracture site compared with short-segment screws (0.77 vs. 2.0 mm, P = 0.039). They also resulted in a greater trend towards greater baseline stiffness, (807.32 ± 216.95 N/mm vs. 583.12 ± 130.1 N/mm, P = 0.072). There was no difference in stiffness after cyclic loading or survival through 50,000 cycles between the long-segment and short-segment groups.</p><p><strong>Conclusion: </strong>Long-segment blocking screws added to an intramedullary nail construct resulted in decreased horizontal translation at the fracture site compared with short-segment screws in this model of a geriatric proximal tibia fracture.</p><p><strong>Clinical relevance: </strong>Blocking screws are commonly used to aid in fracture alignment during intramedullary nailing of proximal tibia fractures. Even when not required to attain or maintain alignment, the addition of a blocking screw in either the proximal or the distal (long) segment may help mitigate the \\\"Bell-Clapper Effect\\\" in geriatric patients.</p>\",\"PeriodicalId\":16644,\"journal\":{\"name\":\"Journal of Orthopaedic Trauma\",\"volume\":\" \",\"pages\":\"e4-e8\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Orthopaedic Trauma\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/BOT.0000000000002683\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthopaedic Trauma","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/BOT.0000000000002683","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
摘要
目的确定使用远端(长)节阻断螺钉与近端(短)节阻断螺钉进行髓内钉固定后,老年关节外胫骨近端骨折模型的硬度和水平平移的变化:在 12 个老年尸体胫骨上创建了不稳定的胫骨近端关节外骨折(OTA/AO 41-A3)。用标准结构(4枚近端螺钉和2枚远端螺钉)锁定髓内钉。然后将标本分为两组(每组 6 对匹配的标本)。第一组在近端(短节段)髓内钉外侧放置阻断螺钉。第 2 组的阻断螺钉放置在骨折远端 1 厘米处,位于钢钉内侧(长节段)。然后对标本进行轴向加载并循环至失效或循环完成(50,000 次):结果:与短节段螺钉相比,长节段阻断螺钉明显减少了骨折部位的水平平移量(0.77 mm vs. 2.0 mm,P = 0.039)。此外,长段阻断螺钉的基线硬度也有增加的趋势(807.32 ± 216.95 N/mm vs. 583.12 ± 130.1 N/mm,P = 0.072)。长节段组和短节段组在循环加载后的刚度或50,000次循环后的存活率方面没有差异:结论:在这一老年胫骨近端骨折模型中,与短节螺钉相比,在髓内钉结构中添加长节阻挡螺钉可减少骨折部位的水平平移:在胫骨近端骨折的髓内钉治疗中,阻断螺钉通常用于帮助骨折对位。即使不需要达到或保持对位,在近端或远端(长)节段增加阻挡螺钉也有助于减轻老年患者的 "贝尔-卡勒效应"。
Do Long-Segment Blocking Screws Increase the Stability of Intramedullary Nail Fixation in Proximal Tibia Fractures, Eliminating the "Bell-Clapper Effect?"
Objectives: To determine change in stiffness and horizontal translation of a geriatric extra-articular proximal tibia fracture model after intramedullary nailing with distal (long)-segment blocking screws versus proximal (short)-segment blocking screws.
Methods: Unstable extra-articular proximal tibia fractures (OTA/AO 41-A3) were created in 12 geriatric cadaveric tibias. Intramedullary nails were locked with a standard construct (4 proximal screws and 2 distal screws). Specimens were then divided into 2 groups (6 matched pairs per group). Group 1 had a blocking screw placed lateral to the nail in the proximal segment (short segment). Group 2 had a blocking screw placed 1 cm distal to the fracture and medial to the nail (long segment). Specimens were then axially loaded and cycled to failure or cycle completion (50,000 cycles).
Results: Long-segment blocking screws significantly decreased the amount of horizontal translation at the fracture site compared with short-segment screws (0.77 vs. 2.0 mm, P = 0.039). They also resulted in a greater trend towards greater baseline stiffness, (807.32 ± 216.95 N/mm vs. 583.12 ± 130.1 N/mm, P = 0.072). There was no difference in stiffness after cyclic loading or survival through 50,000 cycles between the long-segment and short-segment groups.
Conclusion: Long-segment blocking screws added to an intramedullary nail construct resulted in decreased horizontal translation at the fracture site compared with short-segment screws in this model of a geriatric proximal tibia fracture.
Clinical relevance: Blocking screws are commonly used to aid in fracture alignment during intramedullary nailing of proximal tibia fractures. Even when not required to attain or maintain alignment, the addition of a blocking screw in either the proximal or the distal (long) segment may help mitigate the "Bell-Clapper Effect" in geriatric patients.
期刊介绍:
Journal of Orthopaedic Trauma is devoted exclusively to the diagnosis and management of hard and soft tissue trauma, including injuries to bone, muscle, ligament, and tendons, as well as spinal cord injuries. Under the guidance of a distinguished international board of editors, the journal provides the most current information on diagnostic techniques, new and improved surgical instruments and procedures, surgical implants and prosthetic devices, bioplastics and biometals; and physical therapy and rehabilitation.