再矿化剂对激光和非激光漂白搪瓷表面侵蚀的影响:体外研究。

Q2 Dentistry
Journal of Conservative Dentistry Pub Date : 2023-07-01 Epub Date: 2023-07-28 DOI:10.4103/jcd.jcd_139_23
Swapnil Vats, Dakshita Joy Sinha, Sarita Singh, Ruchi Rathi, Swati Jha, Isha Singh
{"title":"再矿化剂对激光和非激光漂白搪瓷表面侵蚀的影响:体外研究。","authors":"Swapnil Vats, Dakshita Joy Sinha, Sarita Singh, Ruchi Rathi, Swati Jha, Isha Singh","doi":"10.4103/jcd.jcd_139_23","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>Assessment of remineralizing agent's effect on laser and nonlaser bleached enamel surfaces subjected to erosion.</p><p><strong>Materials and methods: </strong>In this study, 80 extracted human permanent anteriors were collected and divided into 4 groups with 20 teeth per sample. Enamel specimen of 3 mm × 3 mm were made using polyvinyl chloride rings and acrylic and randomly divided into four groups. Then the specimens were subjected to initial microhardness test using Vicker's hardness tester (AVK-CO, Mitutoyo, Japan). Two indentations were placed at 100 mm from one another in the center of all the samples. Bleaching with laser and without laser using hydrogen peroxide was performed followed by remineralization in the groups (Groups 1a and 2a) and then were subjected to erosion. The final hardness was measured using the above method used for initial microhardness.</p><p><strong>Results: </strong>Microhardness in the remineralized groups showed least variation. The group in which laser bleaching was performed along with remineralization as compared with nonlaser bleaching group with remineralization showed improvement in microhardness but the data was not statistically significant. A significant difference was noted between the laser and remineralization group when compared with the groups in which no remineralization was done.</p><p><strong>Conclusion: </strong>After bleaching the enamel surface is more prone to erosion, so to improve the microhardness of bleached enamel a remineralizing agent should be used. A combination of diode laser bleaching and remineralizing agents leads to improved microhardness of the bleached enamel thus proving this combination to be efficacious.</p>","PeriodicalId":38892,"journal":{"name":"Journal of Conservative Dentistry","volume":"26 4","pages":"388-394"},"PeriodicalIF":0.0000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10497080/pdf/","citationCount":"0","resultStr":"{\"title\":\"Effect of remineralizing agent on laser and nonlaser bleached enamel surfaces subjected to erosion: An <i>in vitro</i> study.\",\"authors\":\"Swapnil Vats, Dakshita Joy Sinha, Sarita Singh, Ruchi Rathi, Swati Jha, Isha Singh\",\"doi\":\"10.4103/jcd.jcd_139_23\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aim: </strong>Assessment of remineralizing agent's effect on laser and nonlaser bleached enamel surfaces subjected to erosion.</p><p><strong>Materials and methods: </strong>In this study, 80 extracted human permanent anteriors were collected and divided into 4 groups with 20 teeth per sample. Enamel specimen of 3 mm × 3 mm were made using polyvinyl chloride rings and acrylic and randomly divided into four groups. Then the specimens were subjected to initial microhardness test using Vicker's hardness tester (AVK-CO, Mitutoyo, Japan). Two indentations were placed at 100 mm from one another in the center of all the samples. Bleaching with laser and without laser using hydrogen peroxide was performed followed by remineralization in the groups (Groups 1a and 2a) and then were subjected to erosion. The final hardness was measured using the above method used for initial microhardness.</p><p><strong>Results: </strong>Microhardness in the remineralized groups showed least variation. The group in which laser bleaching was performed along with remineralization as compared with nonlaser bleaching group with remineralization showed improvement in microhardness but the data was not statistically significant. A significant difference was noted between the laser and remineralization group when compared with the groups in which no remineralization was done.</p><p><strong>Conclusion: </strong>After bleaching the enamel surface is more prone to erosion, so to improve the microhardness of bleached enamel a remineralizing agent should be used. A combination of diode laser bleaching and remineralizing agents leads to improved microhardness of the bleached enamel thus proving this combination to be efficacious.</p>\",\"PeriodicalId\":38892,\"journal\":{\"name\":\"Journal of Conservative Dentistry\",\"volume\":\"26 4\",\"pages\":\"388-394\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10497080/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Conservative Dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/jcd.jcd_139_23\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/7/28 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Conservative Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jcd.jcd_139_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/7/28 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

摘要

目的:评估再矿化剂对激光和非激光漂白搪瓷表面侵蚀的影响。材料和方法:本研究收集了80颗提取的人类恒牙前部,并将其分为4组,每组20颗。用聚氯乙烯环和丙烯酸制成3mm×3mm的搪瓷试样,并随机分为四组。然后使用Vicker硬度计(AVK-CO,Mitutoyo,Japan)对试样进行初始显微硬度测试。在所有样品的中心放置两个彼此相距100mm的压痕。使用激光和不使用激光使用过氧化氢进行漂白,然后在组(组1a和2a)中再矿化,然后进行侵蚀。使用上述用于初始显微硬度的方法测量最终硬度。结果:再矿化组的显微硬度变化最小。与未激光漂白的再矿化组相比,激光漂白与再矿化一起进行的组显示出显微硬度的改善,但数据没有统计学意义。与未进行再矿化的组相比,激光和再矿化组之间存在显著差异。结论:漂白后的牙釉质表面更易发生侵蚀,应采用再矿化剂提高漂白后的釉质显微硬度。二极管激光漂白和再矿化剂的组合提高了漂白搪瓷的显微硬度,从而证明了这种组合是有效的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Effect of remineralizing agent on laser and nonlaser bleached enamel surfaces subjected to erosion: An <i>in vitro</i> study.

Effect of remineralizing agent on laser and nonlaser bleached enamel surfaces subjected to erosion: An <i>in vitro</i> study.

Effect of remineralizing agent on laser and nonlaser bleached enamel surfaces subjected to erosion: An <i>in vitro</i> study.

Effect of remineralizing agent on laser and nonlaser bleached enamel surfaces subjected to erosion: An in vitro study.

Aim: Assessment of remineralizing agent's effect on laser and nonlaser bleached enamel surfaces subjected to erosion.

Materials and methods: In this study, 80 extracted human permanent anteriors were collected and divided into 4 groups with 20 teeth per sample. Enamel specimen of 3 mm × 3 mm were made using polyvinyl chloride rings and acrylic and randomly divided into four groups. Then the specimens were subjected to initial microhardness test using Vicker's hardness tester (AVK-CO, Mitutoyo, Japan). Two indentations were placed at 100 mm from one another in the center of all the samples. Bleaching with laser and without laser using hydrogen peroxide was performed followed by remineralization in the groups (Groups 1a and 2a) and then were subjected to erosion. The final hardness was measured using the above method used for initial microhardness.

Results: Microhardness in the remineralized groups showed least variation. The group in which laser bleaching was performed along with remineralization as compared with nonlaser bleaching group with remineralization showed improvement in microhardness but the data was not statistically significant. A significant difference was noted between the laser and remineralization group when compared with the groups in which no remineralization was done.

Conclusion: After bleaching the enamel surface is more prone to erosion, so to improve the microhardness of bleached enamel a remineralizing agent should be used. A combination of diode laser bleaching and remineralizing agents leads to improved microhardness of the bleached enamel thus proving this combination to be efficacious.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Conservative Dentistry
Journal of Conservative Dentistry Dentistry-Dentistry (all)
CiteScore
2.10
自引率
0.00%
发文量
114
期刊介绍: The Journal of Conservative Dentistry (ISSN - 0972-0707) is the official journal of the Indian Association of Conservative Dentistry and Endodontics (IACDE). Our journal publishes scientific articles, case reports, short communications, invited reviews and comparative studies evaluating materials and methods in the fields of Conservative Dentistry, Dental Materials and Endodontics. J Conserv Dent has a diverse readership that includes full-time clinicians, full-time academicians, residents, students and scientists. Effective communication with this diverse readership requires careful attention to writing style.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信