鼻盒经皮固定舟状骨骨折的解剖学研究。

IF 2 2区 医学 Q2 ORTHOPEDICS
Journal of Hand Surgery-European Volume Pub Date : 2023-12-01 Epub Date: 2023-07-22 DOI:10.1177/17531934231188461
Mỹ-Vân Nguyễn, Camilo Chaves, Vincent Crenn, Philippe Bellemère
{"title":"鼻盒经皮固定舟状骨骨折的解剖学研究。","authors":"Mỹ-Vân Nguyễn, Camilo Chaves, Vincent Crenn, Philippe Bellemère","doi":"10.1177/17531934231188461","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of the present anatomical study was to assess the dorso-radial approach for percutaneous fixation of scaphoid wist fractures. Through the anatomical snuffbox, cannulated screws or 1.2 mm K-wires were inserted into the scaphoids of 20 fresh-frozen cadavers. No tendon injuries were observed. There were two lesions of the radial artery, and three lesions of the sensory branches of the radial nerve. After dissection and three-dimensional CT reconstruction, the K-wire or screw position was described in relation to the scaphoid centroid and its longitudinal axis. The mean distance between the device and the scaphoid centroid was 2.8 mm (SD 1.4, range 0.6 to 6.1). The mean angle between the device and the scaphoid's longitudinal axis was 29° (SD 11, range 6.5 to 54). Rather than percutaneous fixation, an open approach with a modest incision might be safer for identifying and protecting both the radial artery and the sensory nerves. This approach would make perpendicular fixation possible for specific patterns of scaphoid fracture orientated approximately 60° from the longitudinal axis.</p>","PeriodicalId":54813,"journal":{"name":"Journal of Hand Surgery-European Volume","volume":null,"pages":null},"PeriodicalIF":2.0000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Percutaneous fixation of scaphoid fractures through the snuffbox: an anatomical study.\",\"authors\":\"Mỹ-Vân Nguyễn, Camilo Chaves, Vincent Crenn, Philippe Bellemère\",\"doi\":\"10.1177/17531934231188461\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The aim of the present anatomical study was to assess the dorso-radial approach for percutaneous fixation of scaphoid wist fractures. Through the anatomical snuffbox, cannulated screws or 1.2 mm K-wires were inserted into the scaphoids of 20 fresh-frozen cadavers. No tendon injuries were observed. There were two lesions of the radial artery, and three lesions of the sensory branches of the radial nerve. After dissection and three-dimensional CT reconstruction, the K-wire or screw position was described in relation to the scaphoid centroid and its longitudinal axis. The mean distance between the device and the scaphoid centroid was 2.8 mm (SD 1.4, range 0.6 to 6.1). The mean angle between the device and the scaphoid's longitudinal axis was 29° (SD 11, range 6.5 to 54). Rather than percutaneous fixation, an open approach with a modest incision might be safer for identifying and protecting both the radial artery and the sensory nerves. This approach would make perpendicular fixation possible for specific patterns of scaphoid fracture orientated approximately 60° from the longitudinal axis.</p>\",\"PeriodicalId\":54813,\"journal\":{\"name\":\"Journal of Hand Surgery-European Volume\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2023-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Hand Surgery-European Volume\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/17531934231188461\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/7/22 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Hand Surgery-European Volume","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/17531934231188461","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/7/22 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

本解剖研究的目的是评估背桡骨入路经皮固定舟状腕骨折。通过解剖鼻烟壶,将空心螺钉或1.2 mm k -丝插入20具新鲜冷冻尸体的舟骨。未见肌腱损伤。桡动脉病变2例,桡神经感觉支病变3例。解剖和三维CT重建后,描述k针或螺钉相对于舟状骨心及其纵轴的位置。装置与舟状骨质心之间的平均距离为2.8 mm (SD 1.4,范围0.6至6.1)。器械与舟状骨纵轴之间的平均夹角为29°(SD 11,范围6.5至54)。相对于经皮固定,一个适当切口的开放入路对于识别和保护桡动脉和感觉神经可能更安全。对于舟状骨骨折的特定类型,这种方法使垂直固定成为可能,舟状骨骨折的方向与纵轴约60°。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Percutaneous fixation of scaphoid fractures through the snuffbox: an anatomical study.

The aim of the present anatomical study was to assess the dorso-radial approach for percutaneous fixation of scaphoid wist fractures. Through the anatomical snuffbox, cannulated screws or 1.2 mm K-wires were inserted into the scaphoids of 20 fresh-frozen cadavers. No tendon injuries were observed. There were two lesions of the radial artery, and three lesions of the sensory branches of the radial nerve. After dissection and three-dimensional CT reconstruction, the K-wire or screw position was described in relation to the scaphoid centroid and its longitudinal axis. The mean distance between the device and the scaphoid centroid was 2.8 mm (SD 1.4, range 0.6 to 6.1). The mean angle between the device and the scaphoid's longitudinal axis was 29° (SD 11, range 6.5 to 54). Rather than percutaneous fixation, an open approach with a modest incision might be safer for identifying and protecting both the radial artery and the sensory nerves. This approach would make perpendicular fixation possible for specific patterns of scaphoid fracture orientated approximately 60° from the longitudinal axis.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.10
自引率
16.70%
发文量
190
审稿时长
4-8 weeks
期刊介绍: The Journal of Hand Surgery (European Volume) is essential reading for everyone involved in restoring the function to the hand and upper limb. Dedicated to the needs of hand, plastic, reconstructive and orthopaedic surgeons, it publishes the best selection of current papers on hand surgery. The journal regularly highlights key developments in a range of original, authoritative and highly informative articles written by distinguished experts from around the world. Rapid coverage of the latest research, techniques, trends and ideas to make sure you stay up-to-date. Subjects covered include: joint replacement fracture and joint injuries microvascular surgery congenital hand problems You will also find editorials, book reviews, conference dates, case studies, detailed coverage of new techniques and full-length reviews articles.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信