Emanuel C Haug, Jeremy T Hines, Benjamin Dalkin, Patrick J Dunne, Wendy M Novicoff, Lucian C Warth, R Michael Meneghini, James A Browne
{"title":"在具有挑战性的临床情况下,静态无关节膝关节垫片与高发病率相关。","authors":"Emanuel C Haug, Jeremy T Hines, Benjamin Dalkin, Patrick J Dunne, Wendy M Novicoff, Lucian C Warth, R Michael Meneghini, James A Browne","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The morbidity associated with the use of static non-articulating knee spacers for the treatment of periprosthetic joint infection (PJI) in challenging clinical scenarios has not been well described. From 2011-2019, 63 molded block static spacers were utilized at two academic institutions for the treatment of PJI with associated severe soft tissue compromise (59%), collateral ligament deficiency (49%), extensor mechanism compromise (48%), or type 3 bone defects (44%). Complications and outcomes were assessed. Complications with the use of static spacers were common and included further bone loss (46%), spacer migration (16%), extensor mechanism compromise (16%), cast or related soft tissue injuries (16%), fracture (13%), and spacer breakage (3%). Ultimately, 22% of patients underwent amputation. Patient variables such as age and body mass index were not associated with outcomes. Static knee spacers are associated with substantial morbidity in challenging clinical scenarios and alternatives may need to be considered. (Journal of Surgical Orthopaedic Advances 32(2):122-126, 2023).</p>","PeriodicalId":17143,"journal":{"name":"Journal of surgical orthopaedic advances","volume":"32 2","pages":"122-126"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Static Non-articulating Knee Spacers Are Associated with a High Degree of Morbidity in Challenging Clinical Scenarios.\",\"authors\":\"Emanuel C Haug, Jeremy T Hines, Benjamin Dalkin, Patrick J Dunne, Wendy M Novicoff, Lucian C Warth, R Michael Meneghini, James A Browne\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The morbidity associated with the use of static non-articulating knee spacers for the treatment of periprosthetic joint infection (PJI) in challenging clinical scenarios has not been well described. From 2011-2019, 63 molded block static spacers were utilized at two academic institutions for the treatment of PJI with associated severe soft tissue compromise (59%), collateral ligament deficiency (49%), extensor mechanism compromise (48%), or type 3 bone defects (44%). Complications and outcomes were assessed. Complications with the use of static spacers were common and included further bone loss (46%), spacer migration (16%), extensor mechanism compromise (16%), cast or related soft tissue injuries (16%), fracture (13%), and spacer breakage (3%). Ultimately, 22% of patients underwent amputation. Patient variables such as age and body mass index were not associated with outcomes. Static knee spacers are associated with substantial morbidity in challenging clinical scenarios and alternatives may need to be considered. (Journal of Surgical Orthopaedic Advances 32(2):122-126, 2023).</p>\",\"PeriodicalId\":17143,\"journal\":{\"name\":\"Journal of surgical orthopaedic advances\",\"volume\":\"32 2\",\"pages\":\"122-126\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of surgical orthopaedic advances\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of surgical orthopaedic advances","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Static Non-articulating Knee Spacers Are Associated with a High Degree of Morbidity in Challenging Clinical Scenarios.
The morbidity associated with the use of static non-articulating knee spacers for the treatment of periprosthetic joint infection (PJI) in challenging clinical scenarios has not been well described. From 2011-2019, 63 molded block static spacers were utilized at two academic institutions for the treatment of PJI with associated severe soft tissue compromise (59%), collateral ligament deficiency (49%), extensor mechanism compromise (48%), or type 3 bone defects (44%). Complications and outcomes were assessed. Complications with the use of static spacers were common and included further bone loss (46%), spacer migration (16%), extensor mechanism compromise (16%), cast or related soft tissue injuries (16%), fracture (13%), and spacer breakage (3%). Ultimately, 22% of patients underwent amputation. Patient variables such as age and body mass index were not associated with outcomes. Static knee spacers are associated with substantial morbidity in challenging clinical scenarios and alternatives may need to be considered. (Journal of Surgical Orthopaedic Advances 32(2):122-126, 2023).