Francesca DE Luca, Martin Bolin, Lennart Blomqvist, Cecilia Wassberg, Heather Martin, Anna Falk Delgado
{"title":"11c -蛋氨酸PET/MRI在开颅术后患者中的应用:零回声时间和头部图谱与基于ct的衰减校正","authors":"Francesca DE Luca, Martin Bolin, Lennart Blomqvist, Cecilia Wassberg, Heather Martin, Anna Falk Delgado","doi":"10.23736/S1824-4785.22.03389-1","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Attenuation correction (AC) is an important topic in PET/MRI and particularly challenging after brain tumor surgery, near metal implants, adjacent bone and burr holes. In this study, we evaluated the performance of two MR-driven AC methods, zero-echo-time AC (ZTE-AC) and atlas-AC, in comparison to reference standard CT-AC in patients with surgically treated brain tumors at <sup>11</sup>C-methionine PET/MRI.</p><p><strong>Methods: </strong>This retrospective study investigated seven postoperative patients with neuropathologically confirmed brain tumor at <sup>11</sup>C-methionine PET/MRI. Three AC maps - ZTE-AC, atlas-AC and reference standard CT-AC - were generated for each patient. Standardized uptake values (SUV) were obtained at the metal implant, adjacent bone and burr hole. Standard uptake ratio (SUR) SURmetal/mirror, SURbone/mirror and SURburrhole/mirror were then calculated and analyzed with Bland-Altman, Pearson correlation and intraclass correlation reliability.</p><p><strong>Results: </strong>Smaller mean percent bias range (Bland-Altman) was found for ZTE-AC than atlas-AC in all analyses (metal ZTE -0.46 to -0.02, metal atlas -3.57 to -3.26; bone ZTE -4.60 to -2.16, bone atlas -5.25 to -3.81; burr hole ZTE -0.95 to -0.52, burr hole atlas 7.86 to 8.87). Percent SD range (Bland-Altman) was large for both methods in all analyses, with lower absolute values for ZTE-AC (ZTE 7.02-8.49; atlas 11.47-14.83). A very strong correlation (Pearson correlation) was demonstrated for both methods compared to CT-AC (ZTE ρ 0.97-0.99, P<0.001; atlas ρ 0.88-0.91, P≤0.009) with higher absolute values for ZTE. An excellent intraclass correlation coefficient was found across all analyses for ZTE, atlas and CT maps (ICC ≥0.88).</p><p><strong>Conclusions: </strong>ZTE for MR-driven PET attenuation correction presented a more comparable performance to reference standard CT-AC at the postoperative site. ZTE-AC may serve as a useful diagnostic tool for MR-driven AC in patients with surgically treated brain tumors.</p>","PeriodicalId":23069,"journal":{"name":"The quarterly journal of nuclear medicine and molecular imaging : official publication of the Italian Association of Nuclear Medicine (AIMN) [and] the International Association of Radiopharmacology (IAR), [and] Section of the Society of...","volume":"67 3","pages":"215-222"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"11C-methionine PET/MRI in postoperative patients after craniotomy: zero echo time and head atlas versus CT-based attenuation correction.\",\"authors\":\"Francesca DE Luca, Martin Bolin, Lennart Blomqvist, Cecilia Wassberg, Heather Martin, Anna Falk Delgado\",\"doi\":\"10.23736/S1824-4785.22.03389-1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Attenuation correction (AC) is an important topic in PET/MRI and particularly challenging after brain tumor surgery, near metal implants, adjacent bone and burr holes. In this study, we evaluated the performance of two MR-driven AC methods, zero-echo-time AC (ZTE-AC) and atlas-AC, in comparison to reference standard CT-AC in patients with surgically treated brain tumors at <sup>11</sup>C-methionine PET/MRI.</p><p><strong>Methods: </strong>This retrospective study investigated seven postoperative patients with neuropathologically confirmed brain tumor at <sup>11</sup>C-methionine PET/MRI. Three AC maps - ZTE-AC, atlas-AC and reference standard CT-AC - were generated for each patient. Standardized uptake values (SUV) were obtained at the metal implant, adjacent bone and burr hole. Standard uptake ratio (SUR) SURmetal/mirror, SURbone/mirror and SURburrhole/mirror were then calculated and analyzed with Bland-Altman, Pearson correlation and intraclass correlation reliability.</p><p><strong>Results: </strong>Smaller mean percent bias range (Bland-Altman) was found for ZTE-AC than atlas-AC in all analyses (metal ZTE -0.46 to -0.02, metal atlas -3.57 to -3.26; bone ZTE -4.60 to -2.16, bone atlas -5.25 to -3.81; burr hole ZTE -0.95 to -0.52, burr hole atlas 7.86 to 8.87). Percent SD range (Bland-Altman) was large for both methods in all analyses, with lower absolute values for ZTE-AC (ZTE 7.02-8.49; atlas 11.47-14.83). A very strong correlation (Pearson correlation) was demonstrated for both methods compared to CT-AC (ZTE ρ 0.97-0.99, P<0.001; atlas ρ 0.88-0.91, P≤0.009) with higher absolute values for ZTE. An excellent intraclass correlation coefficient was found across all analyses for ZTE, atlas and CT maps (ICC ≥0.88).</p><p><strong>Conclusions: </strong>ZTE for MR-driven PET attenuation correction presented a more comparable performance to reference standard CT-AC at the postoperative site. ZTE-AC may serve as a useful diagnostic tool for MR-driven AC in patients with surgically treated brain tumors.</p>\",\"PeriodicalId\":23069,\"journal\":{\"name\":\"The quarterly journal of nuclear medicine and molecular imaging : official publication of the Italian Association of Nuclear Medicine (AIMN) [and] the International Association of Radiopharmacology (IAR), [and] Section of the Society of...\",\"volume\":\"67 3\",\"pages\":\"215-222\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The quarterly journal of nuclear medicine and molecular imaging : official publication of the Italian Association of Nuclear Medicine (AIMN) [and] the International Association of Radiopharmacology (IAR), [and] Section of the Society of...\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23736/S1824-4785.22.03389-1\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The quarterly journal of nuclear medicine and molecular imaging : official publication of the Italian Association of Nuclear Medicine (AIMN) [and] the International Association of Radiopharmacology (IAR), [and] Section of the Society of...","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23736/S1824-4785.22.03389-1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
11C-methionine PET/MRI in postoperative patients after craniotomy: zero echo time and head atlas versus CT-based attenuation correction.
Background: Attenuation correction (AC) is an important topic in PET/MRI and particularly challenging after brain tumor surgery, near metal implants, adjacent bone and burr holes. In this study, we evaluated the performance of two MR-driven AC methods, zero-echo-time AC (ZTE-AC) and atlas-AC, in comparison to reference standard CT-AC in patients with surgically treated brain tumors at 11C-methionine PET/MRI.
Methods: This retrospective study investigated seven postoperative patients with neuropathologically confirmed brain tumor at 11C-methionine PET/MRI. Three AC maps - ZTE-AC, atlas-AC and reference standard CT-AC - were generated for each patient. Standardized uptake values (SUV) were obtained at the metal implant, adjacent bone and burr hole. Standard uptake ratio (SUR) SURmetal/mirror, SURbone/mirror and SURburrhole/mirror were then calculated and analyzed with Bland-Altman, Pearson correlation and intraclass correlation reliability.
Results: Smaller mean percent bias range (Bland-Altman) was found for ZTE-AC than atlas-AC in all analyses (metal ZTE -0.46 to -0.02, metal atlas -3.57 to -3.26; bone ZTE -4.60 to -2.16, bone atlas -5.25 to -3.81; burr hole ZTE -0.95 to -0.52, burr hole atlas 7.86 to 8.87). Percent SD range (Bland-Altman) was large for both methods in all analyses, with lower absolute values for ZTE-AC (ZTE 7.02-8.49; atlas 11.47-14.83). A very strong correlation (Pearson correlation) was demonstrated for both methods compared to CT-AC (ZTE ρ 0.97-0.99, P<0.001; atlas ρ 0.88-0.91, P≤0.009) with higher absolute values for ZTE. An excellent intraclass correlation coefficient was found across all analyses for ZTE, atlas and CT maps (ICC ≥0.88).
Conclusions: ZTE for MR-driven PET attenuation correction presented a more comparable performance to reference standard CT-AC at the postoperative site. ZTE-AC may serve as a useful diagnostic tool for MR-driven AC in patients with surgically treated brain tumors.