Giuseppe D'Albis, Vincenzo D'Albis, Bart Susca, Micol Palma, Nizar Al Krenawi
{"title":"种植体支撑氧化锆固定局部义齿悬臂后侧区4年临床观察。","authors":"Giuseppe D'Albis, Vincenzo D'Albis, Bart Susca, Micol Palma, Nizar Al Krenawi","doi":"10.34172/joddd.2022.041","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Implant-supported cantilever prostheses enable a more straightforward rehabilitation and may be a therapeutic option to reduce treatment morbidity, costs, and time. This study evaluated the clinical outcomes of fixed implant-supported partial dentures made of monolithic zirconia with a cantilever design to replace missing posterior teeth.</p><p><strong>Methods: </strong>Fifteen partially edentulous patients received 34 implants and were provided with 16 zirconia fixed partial prostheses (FPPs) with one cantilever extension replacing mandibular or maxillary missing posterior and lateral teeth. Patients were re-examined for up to 4 years. Patient ages ranged from 41 to 65 years, with a mean age of 53±12 years; 47% were female, and 53% were male. The patients were observed for a mean period of 42±6 months with a minimum of 3 years and a maximum of 4 years.</p><p><strong>Results: </strong>Peri-implantitis was observed in two cases. No chipping or fracture of any FPP was detected. Loosening of the abutment screw was a technical complication in one case. The rehabilitation survival rate was 100%. Implant-supported zirconia FPP with one mesial cantilever extension provides an aesthetic, functional treatment alternative to replace missing molars, premolars, and canines. These excellent clinical outcomes occurred over a mean observation time of 42±6 months.</p><p><strong>Conclusion: </strong>Using monolithic zirconia milled with CAD-CAM technology might be an alternative to the metal-ceramic restoration in implant-supported FPP with one cantilever.</p>","PeriodicalId":15599,"journal":{"name":"Journal of Dental Research, Dental Clinics, Dental Prospects","volume":"16 4","pages":"258-263"},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10407873/pdf/","citationCount":"0","resultStr":"{\"title\":\"Implant-supported zirconia fixed partial dentures cantilevered in the lateral-posterior area: A 4-year clinical results.\",\"authors\":\"Giuseppe D'Albis, Vincenzo D'Albis, Bart Susca, Micol Palma, Nizar Al Krenawi\",\"doi\":\"10.34172/joddd.2022.041\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Implant-supported cantilever prostheses enable a more straightforward rehabilitation and may be a therapeutic option to reduce treatment morbidity, costs, and time. This study evaluated the clinical outcomes of fixed implant-supported partial dentures made of monolithic zirconia with a cantilever design to replace missing posterior teeth.</p><p><strong>Methods: </strong>Fifteen partially edentulous patients received 34 implants and were provided with 16 zirconia fixed partial prostheses (FPPs) with one cantilever extension replacing mandibular or maxillary missing posterior and lateral teeth. Patients were re-examined for up to 4 years. Patient ages ranged from 41 to 65 years, with a mean age of 53±12 years; 47% were female, and 53% were male. The patients were observed for a mean period of 42±6 months with a minimum of 3 years and a maximum of 4 years.</p><p><strong>Results: </strong>Peri-implantitis was observed in two cases. No chipping or fracture of any FPP was detected. Loosening of the abutment screw was a technical complication in one case. The rehabilitation survival rate was 100%. Implant-supported zirconia FPP with one mesial cantilever extension provides an aesthetic, functional treatment alternative to replace missing molars, premolars, and canines. These excellent clinical outcomes occurred over a mean observation time of 42±6 months.</p><p><strong>Conclusion: </strong>Using monolithic zirconia milled with CAD-CAM technology might be an alternative to the metal-ceramic restoration in implant-supported FPP with one cantilever.</p>\",\"PeriodicalId\":15599,\"journal\":{\"name\":\"Journal of Dental Research, Dental Clinics, Dental Prospects\",\"volume\":\"16 4\",\"pages\":\"258-263\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10407873/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Dental Research, Dental Clinics, Dental Prospects\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.34172/joddd.2022.041\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Dental Research, Dental Clinics, Dental Prospects","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.34172/joddd.2022.041","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Dentistry","Score":null,"Total":0}
Implant-supported zirconia fixed partial dentures cantilevered in the lateral-posterior area: A 4-year clinical results.
Background: Implant-supported cantilever prostheses enable a more straightforward rehabilitation and may be a therapeutic option to reduce treatment morbidity, costs, and time. This study evaluated the clinical outcomes of fixed implant-supported partial dentures made of monolithic zirconia with a cantilever design to replace missing posterior teeth.
Methods: Fifteen partially edentulous patients received 34 implants and were provided with 16 zirconia fixed partial prostheses (FPPs) with one cantilever extension replacing mandibular or maxillary missing posterior and lateral teeth. Patients were re-examined for up to 4 years. Patient ages ranged from 41 to 65 years, with a mean age of 53±12 years; 47% were female, and 53% were male. The patients were observed for a mean period of 42±6 months with a minimum of 3 years and a maximum of 4 years.
Results: Peri-implantitis was observed in two cases. No chipping or fracture of any FPP was detected. Loosening of the abutment screw was a technical complication in one case. The rehabilitation survival rate was 100%. Implant-supported zirconia FPP with one mesial cantilever extension provides an aesthetic, functional treatment alternative to replace missing molars, premolars, and canines. These excellent clinical outcomes occurred over a mean observation time of 42±6 months.
Conclusion: Using monolithic zirconia milled with CAD-CAM technology might be an alternative to the metal-ceramic restoration in implant-supported FPP with one cantilever.
期刊介绍:
Journal of Dental Research Dental Clinics Dental Prospects (JODDD) is a Platinum* Open Access, peer-reviewed quarterly indexed journal that publishes articles of basic, clinical, and prospective nature in all areas of dentistry and oral health.