适用于滴注和外压型无细胞和浓缩腹水回输治疗的新型和高度可靠的渗漏检查测试。

IF 1.5 4区 医学 Q3 HEMATOLOGY
Therapeutic Apheresis and Dialysis Pub Date : 2023-12-01 Epub Date: 2023-08-18 DOI:10.1111/1744-9987.14048
Yasuko Kobayashi, Nana Ozawa, Tamami Yoshida, Takashi Minowa, Yuki Michinaga, Keita Inui, Koji Hashimoto, Yuji Kamijo
{"title":"适用于滴注和外压型无细胞和浓缩腹水回输治疗的新型和高度可靠的渗漏检查测试。","authors":"Yasuko Kobayashi,&nbsp;Nana Ozawa,&nbsp;Tamami Yoshida,&nbsp;Takashi Minowa,&nbsp;Yuki Michinaga,&nbsp;Keita Inui,&nbsp;Koji Hashimoto,&nbsp;Yuji Kamijo","doi":"10.1111/1744-9987.14048","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>For safe management of cell-free and concentrated ascites reinfusion therapy (CART), a highly reliable leak test for detecting ascites filter damage is essential. However, such a test has not been established for drop-type CART.</p><p><strong>Methods: </strong>We devised two novel leak tests for drop- and external pressure-type CART, manual or pump pressurization methods, using high-pressure loading and pressure monitoring, and investigated their reliability.</p><p><strong>Results: </strong>Both methods could easily load and maintain sufficiently high pressure (>400 Torr) on the hollow fibers for 2 min. No result deviation was noted between different operators. The pressure drops in both methods were identical and significantly lower than those in the leak test using a special CART machine, the e-CART.</p><p><strong>Conclusion: </strong>The reliability of our revised leak test is equivalent to that of the automatic leak test of e-CART. These highly reliable leak tests may contribute to safety in patients undergoing drop- and external pressure-type CART.</p>","PeriodicalId":23021,"journal":{"name":"Therapeutic Apheresis and Dialysis","volume":" ","pages":"1040-1047"},"PeriodicalIF":1.5000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Novel and highly reliable leak check tests for drop- and external pressure-type cell-free and concentrated ascites reinfusion therapy.\",\"authors\":\"Yasuko Kobayashi,&nbsp;Nana Ozawa,&nbsp;Tamami Yoshida,&nbsp;Takashi Minowa,&nbsp;Yuki Michinaga,&nbsp;Keita Inui,&nbsp;Koji Hashimoto,&nbsp;Yuji Kamijo\",\"doi\":\"10.1111/1744-9987.14048\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>For safe management of cell-free and concentrated ascites reinfusion therapy (CART), a highly reliable leak test for detecting ascites filter damage is essential. However, such a test has not been established for drop-type CART.</p><p><strong>Methods: </strong>We devised two novel leak tests for drop- and external pressure-type CART, manual or pump pressurization methods, using high-pressure loading and pressure monitoring, and investigated their reliability.</p><p><strong>Results: </strong>Both methods could easily load and maintain sufficiently high pressure (>400 Torr) on the hollow fibers for 2 min. No result deviation was noted between different operators. The pressure drops in both methods were identical and significantly lower than those in the leak test using a special CART machine, the e-CART.</p><p><strong>Conclusion: </strong>The reliability of our revised leak test is equivalent to that of the automatic leak test of e-CART. These highly reliable leak tests may contribute to safety in patients undergoing drop- and external pressure-type CART.</p>\",\"PeriodicalId\":23021,\"journal\":{\"name\":\"Therapeutic Apheresis and Dialysis\",\"volume\":\" \",\"pages\":\"1040-1047\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2023-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Therapeutic Apheresis and Dialysis\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/1744-9987.14048\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/8/18 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"HEMATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Therapeutic Apheresis and Dialysis","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/1744-9987.14048","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/8/18 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

引言:为了安全管理无细胞和浓缩腹水回输治疗(CART),一种高度可靠的检测腹水过滤器损伤的渗漏测试至关重要。然而,还没有为跌落型CART建立这样的测试。方法:我们设计了两种新的跌落型和外压型CART泄漏测试,即手动或泵加压方法,使用高压加载和压力监测,并研究了它们的可靠性。结果:两种方法都可以很容易地加载并保持足够高的压力(>400 Torr)在中空纤维上 min.不同操作人员之间未发现结果偏差。两种方法的压降完全相同,并且明显低于使用特殊CART机器e-CART进行的泄漏测试。结论:我们改进的泄漏测试的可靠性与e-CART的自动泄漏测试相当。这些高度可靠的泄漏测试可能有助于接受降压和外压型CART的患者的安全性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Novel and highly reliable leak check tests for drop- and external pressure-type cell-free and concentrated ascites reinfusion therapy.

Introduction: For safe management of cell-free and concentrated ascites reinfusion therapy (CART), a highly reliable leak test for detecting ascites filter damage is essential. However, such a test has not been established for drop-type CART.

Methods: We devised two novel leak tests for drop- and external pressure-type CART, manual or pump pressurization methods, using high-pressure loading and pressure monitoring, and investigated their reliability.

Results: Both methods could easily load and maintain sufficiently high pressure (>400 Torr) on the hollow fibers for 2 min. No result deviation was noted between different operators. The pressure drops in both methods were identical and significantly lower than those in the leak test using a special CART machine, the e-CART.

Conclusion: The reliability of our revised leak test is equivalent to that of the automatic leak test of e-CART. These highly reliable leak tests may contribute to safety in patients undergoing drop- and external pressure-type CART.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Therapeutic Apheresis and Dialysis
Therapeutic Apheresis and Dialysis 医学-泌尿学与肾脏学
CiteScore
3.00
自引率
10.50%
发文量
166
审稿时长
6-12 weeks
期刊介绍: Therapeutic Apheresis and Dialysis is the official peer-reviewed journal of the International Society for Apheresis, the Japanese Society for Apheresis and the Japanese Society for Dialysis Therapy. The Journal publishes original articles, editorial comments, review articles, case reports, meeting abstracts and Communications information on apheresis and dialysis technologies and treatments.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信