Measuring and maintaining organ perfusion in a patient with Takayasu's arteritis undergoing cardiac surgery*

IF 0.8 Q3 ANESTHESIOLOGY
K. Dan, K. Takahashi, A. K. Lefor
{"title":"Measuring and maintaining organ perfusion in a patient with Takayasu's arteritis undergoing cardiac surgery*","authors":"K. Dan,&nbsp;K. Takahashi,&nbsp;A. K. Lefor","doi":"10.1002/anr3.12236","DOIUrl":null,"url":null,"abstract":"<p>Takayasu's arteritis is a rare vasculitis affecting the aorta and its branches. Disease progression can result in arterial stenosis and subsequent organ dysfunction. Estimating organ perfusion by measuring the peripheral blood pressure can be challenging because it may be altered by arterial stenosis. We report the case of a 61-year-old woman with Takayasu's arteritis with aortic and mitral regurgitation who presented for aortic valve replacement and mitral valvuloplasty. Peripheral arterial pressure was considered a less reliable surrogate for organ perfusion because the patient had diminished blood flow in both the lower and upper extremities. In addition to the bilateral radial arterial pressure, the blood pressure in the ascending aorta was monitored to estimate the patient's organ perfusion pressure during cardiopulmonary bypass. The initial target blood pressure was determined based on the pre-operative baseline and modified by measurement of the aortic pressure. Cerebral oximetry using near-infrared spectroscopy and mixed venous saturation was monitored to estimate oxygen supply-demand balance, which helped evaluate cerebral perfusion and determine the transfusion threshold. The entire procedure was uneventful, and no organ dysfunction was observed postoperatively.</p>","PeriodicalId":72186,"journal":{"name":"Anaesthesia reports","volume":"11 2","pages":""},"PeriodicalIF":0.8000,"publicationDate":"2023-07-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://associationofanaesthetists-publications.onlinelibrary.wiley.com/doi/epdf/10.1002/anr3.12236","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Anaesthesia reports","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/anr3.12236","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Takayasu's arteritis is a rare vasculitis affecting the aorta and its branches. Disease progression can result in arterial stenosis and subsequent organ dysfunction. Estimating organ perfusion by measuring the peripheral blood pressure can be challenging because it may be altered by arterial stenosis. We report the case of a 61-year-old woman with Takayasu's arteritis with aortic and mitral regurgitation who presented for aortic valve replacement and mitral valvuloplasty. Peripheral arterial pressure was considered a less reliable surrogate for organ perfusion because the patient had diminished blood flow in both the lower and upper extremities. In addition to the bilateral radial arterial pressure, the blood pressure in the ascending aorta was monitored to estimate the patient's organ perfusion pressure during cardiopulmonary bypass. The initial target blood pressure was determined based on the pre-operative baseline and modified by measurement of the aortic pressure. Cerebral oximetry using near-infrared spectroscopy and mixed venous saturation was monitored to estimate oxygen supply-demand balance, which helped evaluate cerebral perfusion and determine the transfusion threshold. The entire procedure was uneventful, and no organ dysfunction was observed postoperatively.

Abstract Image

心脏手术中高须动脉炎患者器官灌注的测量和维持*
高松动脉炎是一种罕见的影响主动脉及其分支的血管炎。疾病进展可导致动脉狭窄和随后的器官功能障碍。通过测量外周血压来估计器官灌注可能具有挑战性,因为它可能因动脉狭窄而改变。我们报告一例61岁女性高松动脉炎合并主动脉瓣和二尖瓣反流,接受主动脉瓣置换术和二尖瓣成形术。外周动脉压被认为是器官灌注较不可靠的替代指标,因为患者下肢和上肢的血流量都减少了。除了监测双侧桡动脉压外,还监测升主动脉血压,以估计体外循环过程中患者的器官灌注压。最初的目标血压是根据术前基线确定的,并通过测量主动脉压来修改。采用近红外光谱和混合静脉饱和度监测脑血氧饱和度,以估计氧供需平衡,有助于评估脑灌注和确定输血阈值。整个手术过程顺利,术后未见器官功能障碍。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.30
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信