Differences between systolic and diastolic dimensions of the aortic valve annulus in computed tomography angiography in patients undergoing percutaneous implantation of aortic valve prosthesis by catheter

Rafael Cavalcante Silva, José Mariani Jr., Breno de Alencar Araripe Falcão, Antonio Esteves Filho, Cesar Higa Nomura, Luiz Francisco Rodrigues de Ávila, José Rodrigues Parga, Pedro Alves Lemos Neto
{"title":"Differences between systolic and diastolic dimensions of the aortic valve annulus in computed tomography angiography in patients undergoing percutaneous implantation of aortic valve prosthesis by catheter","authors":"Rafael Cavalcante Silva,&nbsp;José Mariani Jr.,&nbsp;Breno de Alencar Araripe Falcão,&nbsp;Antonio Esteves Filho,&nbsp;Cesar Higa Nomura,&nbsp;Luiz Francisco Rodrigues de Ávila,&nbsp;José Rodrigues Parga,&nbsp;Pedro Alves Lemos Neto","doi":"10.1016/j.rbciev.2015.12.012","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Accurate aortic valve annulus sizing has critical importance for the planning of percutaneous transcatheter aortic valve implantation (TAVI) in patients with severe aortic valve stenosis. Although there is a recommendation to perform the measurement during systole, little is known about the importance of the differences between systolic and diastolic dimensions of the annulus.</p></div><div><h3>Methods</h3><p>Consecutive patients referred for TAVI were evaluated with computed tomography for valve annulus sizing during systole and diastole. Area, circumference, minimum and maximum diameters, and their mean derived diameters were obtained in both phases of the cardiac cycle. Bland-Altman plots were constructed to evaluate the differences between the measures.</p></div><div><h3>Results</h3><p>The analysis included 41 patients with severe aortic stenosis. Mean area, circumference, and diameters were slightly greater in systole. However, in 35% of patients, diastolic dimensions were greater. These differences, although statistically significant, were small (the greatest difference of 0.6<!--> <!-->mm in mean diameter). Bland-Altman plots showed good agreement between systolic and diastolic measurements on all parameters evaluated.</p></div><div><h3>Conclusions</h3><p>Small differences were observed in the systolic and diastolic dimensions of the aortic valve annulus with computed tomography scan, which, although statistically significant, probably do not impact the selection of prosthesis or the procedure outcome.</p></div>","PeriodicalId":101094,"journal":{"name":"Revista Brasileira de Cardiologia Invasiva (English Edition)","volume":"23 2","pages":"Pages 130-133"},"PeriodicalIF":0.0000,"publicationDate":"2015-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.rbciev.2015.12.012","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Brasileira de Cardiologia Invasiva (English Edition)","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2214123515000381","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Accurate aortic valve annulus sizing has critical importance for the planning of percutaneous transcatheter aortic valve implantation (TAVI) in patients with severe aortic valve stenosis. Although there is a recommendation to perform the measurement during systole, little is known about the importance of the differences between systolic and diastolic dimensions of the annulus.

Methods

Consecutive patients referred for TAVI were evaluated with computed tomography for valve annulus sizing during systole and diastole. Area, circumference, minimum and maximum diameters, and their mean derived diameters were obtained in both phases of the cardiac cycle. Bland-Altman plots were constructed to evaluate the differences between the measures.

Results

The analysis included 41 patients with severe aortic stenosis. Mean area, circumference, and diameters were slightly greater in systole. However, in 35% of patients, diastolic dimensions were greater. These differences, although statistically significant, were small (the greatest difference of 0.6 mm in mean diameter). Bland-Altman plots showed good agreement between systolic and diastolic measurements on all parameters evaluated.

Conclusions

Small differences were observed in the systolic and diastolic dimensions of the aortic valve annulus with computed tomography scan, which, although statistically significant, probably do not impact the selection of prosthesis or the procedure outcome.

经皮导管置换术患者主动脉瓣环收缩期与舒张期ct血管造影显示的差异
背景:准确的主动脉瓣环大小对于严重主动脉瓣狭窄患者经皮经导管主动脉瓣植入术(TAVI)的规划至关重要。虽然有建议在收缩期进行测量,但很少有人知道收缩期和舒张期环尺寸差异的重要性。方法对连续行TAVI的患者进行收缩期和舒张期瓣膜环大小的计算机断层扫描。在心脏周期的两个阶段得到面积、周长、最小和最大直径及其平均衍生直径。构建Bland-Altman图来评估测量之间的差异。结果纳入41例重度主动脉瓣狭窄患者。收缩期的平均面积、周长和直径略大。然而,35%的患者舒张尺寸增大。这些差异虽然具有统计学意义,但很小(最大差异为平均直径0.6 mm)。Bland-Altman图显示收缩期和舒张期测量结果在所有评估参数上有很好的一致性。结论计算机断层扫描在主动脉瓣环的收缩和舒张尺寸上观察到微小的差异,尽管具有统计学意义,但可能不会影响假体的选择或手术结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信