{"title":"Impact of Region-of-Interest Delineation on Stability and Reproducibility of Liver SNR Measurements in <sup>68</sup> Ga-PSMA PET/CT.","authors":"Masoomeh Fooladi,&nbsp;Sahar Rezaei,&nbsp;Farahnaz Aghahosseini,&nbsp;Yalda Salehi,&nbsp;Nima Kasraie,&nbsp;Peyman Sheikhzadeh","doi":"10.1055/s-0043-1768446","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objective</b>  This study aims to assess the impact of various regions of interest (ROIs) and volumes of interest (VOIs) delineations on the reproducibility of liver signal-to-noise-ratio (SNRliver) measurements, as well as to find the most reproducible way to estimate it in gallium-68 positron emission tomography ( <sup>68</sup> Ga-PET) imaging. We also investigated the SNRliver-weight relationship for these ROIs and VOIs delineations. <b>Methods</b>  A cohort of 40 patients (40 males; mean weight: 76.5 kg [58-115 kg]) with prostate cancer were included. <sup>68</sup> Ga-PET/CT imaging (mean injected activity: 91.4 MBq [51.2 MBq to 134.1 MBq] was performed on a 5-ring bismuth germanium oxide-based Discovery IQ PET/CT using ordered subset expectation maximization image reconstruction algorithm. Afterward, circular ROIs and spherical VOIs with two different diameters of 30 and 40 mm were drawn on the right lobe of the livers. The performance of the various defined regions was evaluated by the average standardized uptake value (SUV <sub>mean</sub> ), standard deviation (SD) of the SUV (SUV <sub>SD</sub> ), SNR <sub>liver</sub> , and SD of the SNR <sub>liver</sub> metrics. <b>Results</b>  There were no significant differences in SUV <sub>mean</sub> among the various ROIs and VOIs ( <i>p</i>  > 0.05). On the other hand, the lower SUV <sub>SD</sub> was obtained by spherical VOI with diameter of 30 mm. The largest SNR <sub>liver</sub> was obtained by ROI (30 mm). The SD of SNR <sub>liver</sub> with ROI (30 mm) was also the largest, while the lowest SD of SNR <sub>liver</sub> was observed for VOI (40 mm). There is a higher correlation coefficient between the patient-dependent parameter of weight and the image quality parameter of SNRliver for both VOI (30 mm) and VOI (40 mm) compared to the ROIs. <b>Conclusion</b>  Our results indicate that SNR <sub>liver</sub> measurements are affected by the size and shape of the respective ROIs and VOIs. The spherical VOI with a 40 mm diameter leads to more stable and reproducible SNR measurement in the liver.</p>","PeriodicalId":23742,"journal":{"name":"World Journal of Nuclear Medicine","volume":null,"pages":null},"PeriodicalIF":0.6000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10202577/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"World Journal of Nuclear Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0043-1768446","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Objective  This study aims to assess the impact of various regions of interest (ROIs) and volumes of interest (VOIs) delineations on the reproducibility of liver signal-to-noise-ratio (SNRliver) measurements, as well as to find the most reproducible way to estimate it in gallium-68 positron emission tomography ( 68 Ga-PET) imaging. We also investigated the SNRliver-weight relationship for these ROIs and VOIs delineations. Methods  A cohort of 40 patients (40 males; mean weight: 76.5 kg [58-115 kg]) with prostate cancer were included. 68 Ga-PET/CT imaging (mean injected activity: 91.4 MBq [51.2 MBq to 134.1 MBq] was performed on a 5-ring bismuth germanium oxide-based Discovery IQ PET/CT using ordered subset expectation maximization image reconstruction algorithm. Afterward, circular ROIs and spherical VOIs with two different diameters of 30 and 40 mm were drawn on the right lobe of the livers. The performance of the various defined regions was evaluated by the average standardized uptake value (SUV mean ), standard deviation (SD) of the SUV (SUV SD ), SNR liver , and SD of the SNR liver metrics. Results  There were no significant differences in SUV mean among the various ROIs and VOIs ( p  > 0.05). On the other hand, the lower SUV SD was obtained by spherical VOI with diameter of 30 mm. The largest SNR liver was obtained by ROI (30 mm). The SD of SNR liver with ROI (30 mm) was also the largest, while the lowest SD of SNR liver was observed for VOI (40 mm). There is a higher correlation coefficient between the patient-dependent parameter of weight and the image quality parameter of SNRliver for both VOI (30 mm) and VOI (40 mm) compared to the ROIs. Conclusion  Our results indicate that SNR liver measurements are affected by the size and shape of the respective ROIs and VOIs. The spherical VOI with a 40 mm diameter leads to more stable and reproducible SNR measurement in the liver.

Abstract Image

Abstract Image

Abstract Image

兴趣区域划定对68 Ga-PSMA PET/CT肝脏信噪比测量的稳定性和可重复性的影响。
目的本研究旨在评估不同感兴趣区域(roi)和感兴趣体积(VOIs)描绘对肝脏信噪比(SNRliver)测量再现性的影响,并寻找在镓-68正电子发射断层扫描(68 Ga-PET)成像中最具再现性的估计方法。我们还研究了这些roi和voi圈定的snriver -weight关系。方法选取40例患者(男性40例;平均体重:76.5 kg [58-115 kg]),伴有前列腺癌。采用有序子集期望最大化图像重建算法,在5环氧化铋锗基Discovery IQ PET/CT上进行68 Ga-PET/CT成像(平均注入活度:91.4 MBq [51.2 ~ 134.1 MBq])。然后在肝右叶绘制直径分别为30和40 mm的圆形roi和球形voi。通过平均标准化摄取值(SUV mean)、SUV的标准差(SD)、信噪比肝和信噪比肝指标的SD来评估各个定义区域的性能。结果不同roi和voi的SUV均值比较,差异均无统计学意义(p > 0.05)。另一方面,通过直径为30 mm的球形VOI获得较低的SUV SD。ROI获得最大信噪比肝(30 mm)。ROI组(30 mm)肝的信噪比SD最大,VOI组(40 mm)肝的信噪比SD最低。与roi相比,VOI (30 mm)和VOI (40 mm)的患者相关权重参数与snliver的图像质量参数之间的相关系数更高。结论肝的信噪比测量结果受roi和voi的大小和形状的影响。直径为40 mm的球形VOI可在肝脏中实现更稳定和可重复的信噪比测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
World Journal of Nuclear Medicine
World Journal of Nuclear Medicine RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
自引率
16.70%
发文量
118
审稿时长
48 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信