Green analytical toxicology method for determination of synthetic cathinones in oral fluid samples by microextraction by packed sorbent and liquid chromatography-tandem mass spectrometry.
Kelly Francisco da Cunha, Karina Diniz Oliveira, Jose Luiz Costa
{"title":"Green analytical toxicology method for determination of synthetic cathinones in oral fluid samples by microextraction by packed sorbent and liquid chromatography-tandem mass spectrometry.","authors":"Kelly Francisco da Cunha, Karina Diniz Oliveira, Jose Luiz Costa","doi":"10.1007/s11419-023-00671-z","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>We developed and validated a method for quantitative analysis of ten synthetic cathinones in oral fluid (OF) samples, using microextraction by packed sorbent (MEPS) for sample preparation followed by liquid chromatography‒tandem mass spectrometry (LC‒MS/MS).</p><p><strong>Method: </strong>OF samples were collected with a Quantisal™ device and 200 µL was extracted using a C18 MEPS cartridge installed on a semi-automated pipette and then analyzed using LC‒M/SMS.</p><p><strong>Results: </strong>Linearity was achieved between 0.1 and 25 ng/mL, with a limit of detection (LOD) of 0.05 ng/mL and a limit of quantification (LOQ) of 0.1 ng/mL. Imprecision (% relative standard deviation) and bias (%) were better than 11.6% and 7.5%, respectively. The method had good specificity and selectivity against 9 different blank OF samples (from different donors) and 68 pharmaceutical and drugs of abuse with concentrations varying between 400 and 10,000 ng/mL. No evidence of carryover was observed. The analytes were stable after three freeze/thaw cycles and when kept in the autosampler (10 °C) for up to 24 h. The method was successfully applied to quantify 41 authentic positive samples. Methylone (mean 0.6 ng/mL, median 0.2 ng/mL), N-ethylpentylone (mean 16.7 ng/mL, median 0.35 ng/mL), eutylone (mean 39.1 ng/mL, median 3.6 ng/mL), mephedrone (mean 0.5 ng/mL, median 0.5 ng/mL), and 4-chloroethcathinone (8.1 ng/mL) were quantified in these samples.</p><p><strong>Conclusion: </strong>MEPS was an efficient technique for Green Analytical Toxicology purposes, which required only 650 µL organic solvent and 200 µL sodium hydroxide, and the BIN cartridge had a lifespan of 100 sample extractions.</p>","PeriodicalId":12329,"journal":{"name":"Forensic Toxicology","volume":null,"pages":null},"PeriodicalIF":2.8000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Forensic Toxicology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11419-023-00671-z","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/7/28 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"TOXICOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: We developed and validated a method for quantitative analysis of ten synthetic cathinones in oral fluid (OF) samples, using microextraction by packed sorbent (MEPS) for sample preparation followed by liquid chromatography‒tandem mass spectrometry (LC‒MS/MS).
Method: OF samples were collected with a Quantisal™ device and 200 µL was extracted using a C18 MEPS cartridge installed on a semi-automated pipette and then analyzed using LC‒M/SMS.
Results: Linearity was achieved between 0.1 and 25 ng/mL, with a limit of detection (LOD) of 0.05 ng/mL and a limit of quantification (LOQ) of 0.1 ng/mL. Imprecision (% relative standard deviation) and bias (%) were better than 11.6% and 7.5%, respectively. The method had good specificity and selectivity against 9 different blank OF samples (from different donors) and 68 pharmaceutical and drugs of abuse with concentrations varying between 400 and 10,000 ng/mL. No evidence of carryover was observed. The analytes were stable after three freeze/thaw cycles and when kept in the autosampler (10 °C) for up to 24 h. The method was successfully applied to quantify 41 authentic positive samples. Methylone (mean 0.6 ng/mL, median 0.2 ng/mL), N-ethylpentylone (mean 16.7 ng/mL, median 0.35 ng/mL), eutylone (mean 39.1 ng/mL, median 3.6 ng/mL), mephedrone (mean 0.5 ng/mL, median 0.5 ng/mL), and 4-chloroethcathinone (8.1 ng/mL) were quantified in these samples.
Conclusion: MEPS was an efficient technique for Green Analytical Toxicology purposes, which required only 650 µL organic solvent and 200 µL sodium hydroxide, and the BIN cartridge had a lifespan of 100 sample extractions.
期刊介绍:
The journal Forensic Toxicology provides an international forum for publication of studies on toxic substances, drugs of abuse, doping agents, chemical warfare agents, and their metabolisms and analyses, which are related to laws and ethics. It includes original articles, reviews, mini-reviews, short communications, and case reports. Although a major focus of the journal is on the development or improvement of analytical methods for the above-mentioned chemicals in human matrices, appropriate studies with animal experiments are also published.
Forensic Toxicology is the official publication of the Japanese Association of Forensic Toxicology (JAFT) and is the continuation of the Japanese Journal of Forensic Toxicology (ISSN 0915-9606).