{"title":"Combining biophysical models and machine learning to optimize implant geometry and stimulation protocol for intraneural electrodes.","authors":"Simone Romeni,&nbsp;Elena Losanno,&nbsp;Elisabeth Koert,&nbsp;Luca Pierantoni,&nbsp;Ignacio Delgado-Martinez,&nbsp;Xavier Navarro,&nbsp;Silvestro Micera","doi":"10.1088/1741-2552/ace219","DOIUrl":null,"url":null,"abstract":"<p><p><i>Objective.</i>Peripheral nerve interfaces have the potential to restore sensory, motor, and visceral functions. In particular, intraneural interfaces allow targeting deep neural structures with high selectivity, even if their performance strongly depends upon the implantation procedure and the subject's anatomy. Currently, few alternatives exist for the determination of the target subject structural and functional anatomy, and statistical characterizations from cadaveric samples are limited because of their high cost. We propose an optimization workflow that can guide both the pre-surgical planning and the determination of maximally selective multisite stimulation protocols for implants consisting of several intraneural electrodes, and we characterize its performance in silico. We show that the availability of structural and functional information leads to very high performances and allows taking informed decisions on neuroprosthetic design.<i>Approach.</i>We employ hybrid models (HMs) of neuromodulation in conjunction with a machine learning-based surrogate model to determine fiber activation under electrical stimulation, and two steps of optimization through particle swarm optimization to optimize in silico implant geometry, implantation and stimulation protocols using morphological data from the human median nerve at a reduced computational cost.<i>Main results.</i>Our method allows establishing the optimal geometry of multi-electrode transverse intra-fascicular multichannel electrode implants, the optimal number of electrodes to implant, their optimal insertion, and a set of multipolar stimulation protocols that lead in silico to selective activation of all the muscles innervated by the human median nerve.<i>Significance.</i>We show how to use effectively HMs for optimizing personalized neuroprostheses for motor function restoration. We provide in-silico evidences about the potential of multipolar stimulation to increase greatly selectivity. We also show that the knowledge of structural and functional anatomies of the target subject leads to very high selectivity and motivate the development of methods for their<i>in vivo</i>characterization.</p>","PeriodicalId":16753,"journal":{"name":"Journal of neural engineering","volume":"20 4","pages":""},"PeriodicalIF":3.7000,"publicationDate":"2023-07-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of neural engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1741-2552/ace219","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Objective.Peripheral nerve interfaces have the potential to restore sensory, motor, and visceral functions. In particular, intraneural interfaces allow targeting deep neural structures with high selectivity, even if their performance strongly depends upon the implantation procedure and the subject's anatomy. Currently, few alternatives exist for the determination of the target subject structural and functional anatomy, and statistical characterizations from cadaveric samples are limited because of their high cost. We propose an optimization workflow that can guide both the pre-surgical planning and the determination of maximally selective multisite stimulation protocols for implants consisting of several intraneural electrodes, and we characterize its performance in silico. We show that the availability of structural and functional information leads to very high performances and allows taking informed decisions on neuroprosthetic design.Approach.We employ hybrid models (HMs) of neuromodulation in conjunction with a machine learning-based surrogate model to determine fiber activation under electrical stimulation, and two steps of optimization through particle swarm optimization to optimize in silico implant geometry, implantation and stimulation protocols using morphological data from the human median nerve at a reduced computational cost.Main results.Our method allows establishing the optimal geometry of multi-electrode transverse intra-fascicular multichannel electrode implants, the optimal number of electrodes to implant, their optimal insertion, and a set of multipolar stimulation protocols that lead in silico to selective activation of all the muscles innervated by the human median nerve.Significance.We show how to use effectively HMs for optimizing personalized neuroprostheses for motor function restoration. We provide in-silico evidences about the potential of multipolar stimulation to increase greatly selectivity. We also show that the knowledge of structural and functional anatomies of the target subject leads to very high selectivity and motivate the development of methods for theirin vivocharacterization.

结合生物物理模型和机器学习优化植入物几何形状和神经内电极的刺激方案。
目标。周围神经界面具有恢复感觉、运动和内脏功能的潜力。特别是,神经内接口允许以高选择性靶向深层神经结构,即使它们的性能强烈依赖于植入过程和受试者的解剖结构。目前,用于确定目标主体结构和功能解剖结构的替代方法很少,并且由于成本高,从尸体样本中进行统计表征受到限制。我们提出了一个优化工作流程,可以指导术前计划和确定由几个神经内电极组成的植入物的最大选择性多位点刺激方案,并在计算机上表征了其性能。我们表明,结构和功能信息的可用性导致了非常高的性能,并允许在神经假体设计方面做出明智的决定。方法我们采用神经调节的混合模型(HMs)与基于机器学习的代理模型相结合,以确定电刺激下的纤维激活,并通过粒子群优化的两个优化步骤来优化硅植入物的几何形状。植入和刺激方案使用形态学数据从人类正中神经在减少计算成本。主要的结果。我们的方法允许建立多电极横向束内多通道电极植入的最佳几何形状,植入电极的最佳数量,它们的最佳插入,以及一套多极刺激方案,这些方案导致由人体正中神经支配的所有肌肉在硅中选择性激活。我们提供了关于多极刺激的潜力的硅证据,以大大增加选择性。我们还表明,对目标对象的结构和功能解剖结构的了解导致了非常高的选择性,并激发了其体内表征方法的发展。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of neural engineering
Journal of neural engineering 工程技术-工程:生物医学
CiteScore
7.80
自引率
12.50%
发文量
319
审稿时长
4.2 months
期刊介绍: The goal of Journal of Neural Engineering (JNE) is to act as a forum for the interdisciplinary field of neural engineering where neuroscientists, neurobiologists and engineers can publish their work in one periodical that bridges the gap between neuroscience and engineering. The journal publishes articles in the field of neural engineering at the molecular, cellular and systems levels. The scope of the journal encompasses experimental, computational, theoretical, clinical and applied aspects of: Innovative neurotechnology; Brain-machine (computer) interface; Neural interfacing; Bioelectronic medicines; Neuromodulation; Neural prostheses; Neural control; Neuro-rehabilitation; Neurorobotics; Optical neural engineering; Neural circuits: artificial & biological; Neuromorphic engineering; Neural tissue regeneration; Neural signal processing; Theoretical and computational neuroscience; Systems neuroscience; Translational neuroscience; Neuroimaging.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信