Biochemical and Lung Function Test Accuracy for Predicting the Need for Surfactant Therapy in Preterm Infants: A Systematic Review.

IF 2.6 3区 医学 Q1 PEDIATRICS
Neonatology Pub Date : 2023-01-01 DOI:10.1159/000527670
Anna Lavizzari, Chiara Veneroni
{"title":"Biochemical and Lung Function Test Accuracy for Predicting the Need for Surfactant Therapy in Preterm Infants: A Systematic Review.","authors":"Anna Lavizzari,&nbsp;Chiara Veneroni","doi":"10.1159/000527670","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>We evaluate the accuracy of postnatal biochemical and lung function tests performed within 3 h from birth for predicting surfactant need in preterm infants ≤34 weeks' gestation receiving noninvasive respiratory support for respiratory distress syndrome (RDS).</p><p><strong>Methods: </strong>We systematically searched MEDLINE, Embase, The Cochrane Library, PROSPERO, and clinicaltrials.gov databases for studies published from 2000 to November 10, 2021, cross-referencing relevant literature and contacting experts. We included diagnostic accuracy studies and systematic reviews of biochemical or lung function tests identifying the need for surfactant in preterm neonates ≤34 weeks' with RDS not intubated at birth. The authors individually assessed the risk of bias following a tailored QUADAS-2 tool.</p><p><strong>Results: </strong>Eight studies, including 810 infants, met the inclusion criteria. Four tests were included: the click test, the stable microbubble test, the lamellar body count on gastric aspirates, and the forced oscillation technique. The reference standards were transparent criteria for distinguishing the infants according to oxygen requirement, which reflected the current criteria for surfactant therapy. The risk of bias was judged high because of the population selection and exclusion of participants from the analysis. There were no serious concerns regarding blinding and applicability. The individual study sensitivity and specificity range from 0.60 to 1 and from 0.51 to 0.91, respectively. It was not appropriate to combine the accuracy estimates in a meta-analysis because of the heterogeneity of the study characteristics.</p><p><strong>Conclusions: </strong>Current evidence is insufficient to recommend biochemical and lung function tests for tailoring surfactant therapy.</p>","PeriodicalId":18924,"journal":{"name":"Neonatology","volume":null,"pages":null},"PeriodicalIF":2.6000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Neonatology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000527670","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"PEDIATRICS","Score":null,"Total":0}
引用次数: 3

Abstract

Introduction: We evaluate the accuracy of postnatal biochemical and lung function tests performed within 3 h from birth for predicting surfactant need in preterm infants ≤34 weeks' gestation receiving noninvasive respiratory support for respiratory distress syndrome (RDS).

Methods: We systematically searched MEDLINE, Embase, The Cochrane Library, PROSPERO, and clinicaltrials.gov databases for studies published from 2000 to November 10, 2021, cross-referencing relevant literature and contacting experts. We included diagnostic accuracy studies and systematic reviews of biochemical or lung function tests identifying the need for surfactant in preterm neonates ≤34 weeks' with RDS not intubated at birth. The authors individually assessed the risk of bias following a tailored QUADAS-2 tool.

Results: Eight studies, including 810 infants, met the inclusion criteria. Four tests were included: the click test, the stable microbubble test, the lamellar body count on gastric aspirates, and the forced oscillation technique. The reference standards were transparent criteria for distinguishing the infants according to oxygen requirement, which reflected the current criteria for surfactant therapy. The risk of bias was judged high because of the population selection and exclusion of participants from the analysis. There were no serious concerns regarding blinding and applicability. The individual study sensitivity and specificity range from 0.60 to 1 and from 0.51 to 0.91, respectively. It was not appropriate to combine the accuracy estimates in a meta-analysis because of the heterogeneity of the study characteristics.

Conclusions: Current evidence is insufficient to recommend biochemical and lung function tests for tailoring surfactant therapy.

生化和肺功能测试预测早产儿表面活性剂治疗需求的准确性:一项系统综述。
简介:我们评估出生后3小时内进行的出生后生化和肺功能测试的准确性,以预测妊娠≤34周接受无创呼吸支持治疗呼吸窘迫综合征(RDS)的早产儿对表面活性剂的需求。方法:系统检索MEDLINE、Embase、The Cochrane Library、PROSPERO和clinicaltrials.gov数据库,检索2000年至2021年11月10日期间发表的研究,交叉参考相关文献并联系专家。我们纳入了诊断准确性研究和生化或肺功能测试的系统综述,以确定≤34周出生时未插管RDS的早产儿是否需要表面活性剂。作者使用定制的QUADAS-2工具单独评估偏倚风险。结果:8项研究,包括810名婴儿,符合纳入标准。包括四项试验:叩击试验、稳定微泡试验、胃吸物片层体计数和强制振荡技术。参考标准为透明的婴儿需氧量区分标准,反映了目前表面活性剂治疗的标准。偏倚的风险被判断为高,因为从分析中选择了人群和排除了参与者。没有对盲性和适用性的严重关切。个体研究的敏感性和特异性范围分别为0.60 ~ 1和0.51 ~ 0.91。由于研究特征的异质性,不适合在荟萃分析中合并准确度估计。结论:目前的证据不足以推荐生物化学和肺功能测试用于定制表面活性剂治疗。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Neonatology
Neonatology 医学-小儿科
CiteScore
0.60
自引率
4.00%
发文量
91
审稿时长
6-12 weeks
期刊介绍: This highly respected and frequently cited journal is a prime source of information in the area of fetal and neonatal research. Original papers present research on all aspects of neonatology, fetal medicine and developmental biology. These papers encompass both basic science and clinical research including randomized trials, observational studies and epidemiology. Basic science research covers molecular biology, molecular genetics, physiology, biochemistry and pharmacology in fetal and neonatal life. In addition to the classic features the journal accepts papers for the sections Research Briefings and Sources of Neonatal Medicine (historical pieces). Papers reporting results of animal studies should be based upon hypotheses that relate to developmental processes or disorders in the human fetus or neonate.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信