Vito D'Andrea, Giorgia Prontera, Riccardo Carlino, Helena Di Trani, Ilaria Carlettini, Mauro Pittiruti, Giovanni Vento
{"title":"Optical detection of infiltration during peripheral intravenous infusion in neonates.","authors":"Vito D'Andrea, Giorgia Prontera, Riccardo Carlino, Helena Di Trani, Ilaria Carlettini, Mauro Pittiruti, Giovanni Vento","doi":"10.1177/11297298231177723","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Infiltration and extravasation are common complications during peripheral intravenous infusion in the neonatal intensive care unit, and diagnosis is usually clinical, by inspection and palpation. Delay in diagnosis due to poor surveillance or misinterpretation of clinical signs may carry serious damage to the tissues of the neonate. Recently, a novel technology based on optical detection of infiltration has become available.</p><p><strong>Methods: </strong>We have studied two groups of term and preterm infants receiving non-vesicant intravenous infusions by the peripheral route (24G short peripheral cannulas), and we evaluated the incidence of infiltration. In the first group, we have compared the clinical detection of infiltration versus the detection obtained by a novel optical device, blinding the alarms of the device. In the second group, the comparison was carried out without blinding the alarms.</p><p><strong>Results: </strong>Of the neonates included in this study, 60% were female, 86% had a gestational age <37 weeks (34 ± 2.5 weeks) and a mean birth weight of 2.08 ± 0.4 g. Total recorded monitoring time was 1318 h and average monitoring time for each short peripheral cannula was 26.4 h. The incidence of infiltration was 80%, most of them having a Millam score <2. The novel device showed an overall sensitivity of 88.9% in detecting infiltration. Specificity was 84.4%, as evaluated assuming as standard the clinical diagnosis. Interestingly, in cases of documented infiltration, the event was diagnosed by the optical device approximately 6 h before the clinical diagnosis.</p><p><strong>Conclusions: </strong>Continuous monitoring of the insertion site, as automatically ensured by this novel optical device, may play a complementary role in early detection of infiltration, even if the percentage of false positives and false negatives suggests that periodic clinical assessment by expert nurses cannot be omitted.</p>","PeriodicalId":56113,"journal":{"name":"Journal of Vascular Access","volume":" ","pages":"1780-1785"},"PeriodicalIF":1.6000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Vascular Access","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/11297298231177723","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/7/13 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Infiltration and extravasation are common complications during peripheral intravenous infusion in the neonatal intensive care unit, and diagnosis is usually clinical, by inspection and palpation. Delay in diagnosis due to poor surveillance or misinterpretation of clinical signs may carry serious damage to the tissues of the neonate. Recently, a novel technology based on optical detection of infiltration has become available.
Methods: We have studied two groups of term and preterm infants receiving non-vesicant intravenous infusions by the peripheral route (24G short peripheral cannulas), and we evaluated the incidence of infiltration. In the first group, we have compared the clinical detection of infiltration versus the detection obtained by a novel optical device, blinding the alarms of the device. In the second group, the comparison was carried out without blinding the alarms.
Results: Of the neonates included in this study, 60% were female, 86% had a gestational age <37 weeks (34 ± 2.5 weeks) and a mean birth weight of 2.08 ± 0.4 g. Total recorded monitoring time was 1318 h and average monitoring time for each short peripheral cannula was 26.4 h. The incidence of infiltration was 80%, most of them having a Millam score <2. The novel device showed an overall sensitivity of 88.9% in detecting infiltration. Specificity was 84.4%, as evaluated assuming as standard the clinical diagnosis. Interestingly, in cases of documented infiltration, the event was diagnosed by the optical device approximately 6 h before the clinical diagnosis.
Conclusions: Continuous monitoring of the insertion site, as automatically ensured by this novel optical device, may play a complementary role in early detection of infiltration, even if the percentage of false positives and false negatives suggests that periodic clinical assessment by expert nurses cannot be omitted.
期刊介绍:
The Journal of Vascular Access (JVA) is issued six times per year; it considers the publication of original manuscripts dealing with clinical and laboratory investigations in the fast growing field of vascular access. In addition reviews, case reports and clinical trials are welcome, as well as papers dedicated to more practical aspects covering new devices and techniques.
All contributions, coming from all over the world, undergo the peer-review process.
The Journal of Vascular Access is divided into independent sections, each led by Editors of the highest scientific level:
• Dialysis
• Oncology
• Interventional radiology
• Nutrition
• Nursing
• Intensive care
Correspondence related to published papers is also welcome.