Pros and cons of rib unfolding software: a reliability and reproducibility study on trauma patients.

IF 0.8 4区 医学 Q4 EMERGENCY MEDICINE
Ahmet Gürkan Erdemir, Mehmet Ruhi Onur, Ilkay Sedakat Idilman, Bulent Erbil, Erhan Akpınar
{"title":"Pros and cons of rib unfolding software: a reliability and reproducibility study on trauma patients.","authors":"Ahmet Gürkan Erdemir,&nbsp;Mehmet Ruhi Onur,&nbsp;Ilkay Sedakat Idilman,&nbsp;Bulent Erbil,&nbsp;Erhan Akpınar","doi":"10.14744/tjtes.2023.64359","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Examination of all 24 ribs on axial computed tomography (CT) slices might become a leeway and rib fractures (RF) may easily overlook in daily practice. Rib unfolding (RU), a computer-assisted software, that promises rapid assessment of the ribs in a two-dimensional plan, was developed to facilitate rib evaluation. We aimed to evaluate the reliability and reproducibility of RU software for RF detection on CT and to determine the accelerating effect to determine any drawback of RU application.</p><p><strong>Methods: </strong>Fifty-one patients with thoracic trauma formed the sample to be assessed by the observers. The characterization and distribution of RFs on CT images in this sample were recorded independently by the non-observers. Regarding the presence or ab-sence of RF, CT images were assessed blindedly by two radiologists with 5 years (observer-A) and 18 years (observer-B) of experience in thoracic radiology. Each observer assessed the axial CT and RU images on different days under non-observer supervision.</p><p><strong>Results: </strong>A total of 113 RFs were detected in 22 patients. The mean evaluation time for the axial CT images was 146.64 s for ob-server-A and 119.29 s for observer-B. The mean evaluation time for RU images was 66.44 s for observer-A and 32.66 s for observer-B. A statistically significant decrease was observed between the evaluation periods of observer-A and observer-B with RU software compared to the axial CT image assessment (p<0.001). The inter-observer κ value was 0.638, while the intra-observer results showed moderate (κ: 0.441) and good (κ: 0.752) reproducibility comparing the RU and axial CT assessments. Observer-A detected 47.05% non-displaced fractures, 48.93% minimally displaced (≤2 mm) fractures, and 38.77% displaced fractures on RU images (p=0.009). Ob-server-B detected 23.52% non-displaced fractures, 57.44% minimally displaced (≤2 mm) fractures, and 48.97% displaced fractures on RU images (p=0.045).</p><p><strong>Conclusion: </strong>RU software accelerates fracture evaluation, while it has drawbacks including low sensitivity in fracture detection, false negativity, and underestimation of displacement.</p>","PeriodicalId":49398,"journal":{"name":"Ulusal Travma Ve Acil Cerrahi Dergisi-Turkish Journal of Trauma & Emergency Surgery","volume":"29 6","pages":"717-723"},"PeriodicalIF":0.8000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/03/7a/TJTES-29-717.PMC10315928.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ulusal Travma Ve Acil Cerrahi Dergisi-Turkish Journal of Trauma & Emergency Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.14744/tjtes.2023.64359","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"EMERGENCY MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Examination of all 24 ribs on axial computed tomography (CT) slices might become a leeway and rib fractures (RF) may easily overlook in daily practice. Rib unfolding (RU), a computer-assisted software, that promises rapid assessment of the ribs in a two-dimensional plan, was developed to facilitate rib evaluation. We aimed to evaluate the reliability and reproducibility of RU software for RF detection on CT and to determine the accelerating effect to determine any drawback of RU application.

Methods: Fifty-one patients with thoracic trauma formed the sample to be assessed by the observers. The characterization and distribution of RFs on CT images in this sample were recorded independently by the non-observers. Regarding the presence or ab-sence of RF, CT images were assessed blindedly by two radiologists with 5 years (observer-A) and 18 years (observer-B) of experience in thoracic radiology. Each observer assessed the axial CT and RU images on different days under non-observer supervision.

Results: A total of 113 RFs were detected in 22 patients. The mean evaluation time for the axial CT images was 146.64 s for ob-server-A and 119.29 s for observer-B. The mean evaluation time for RU images was 66.44 s for observer-A and 32.66 s for observer-B. A statistically significant decrease was observed between the evaluation periods of observer-A and observer-B with RU software compared to the axial CT image assessment (p<0.001). The inter-observer κ value was 0.638, while the intra-observer results showed moderate (κ: 0.441) and good (κ: 0.752) reproducibility comparing the RU and axial CT assessments. Observer-A detected 47.05% non-displaced fractures, 48.93% minimally displaced (≤2 mm) fractures, and 38.77% displaced fractures on RU images (p=0.009). Ob-server-B detected 23.52% non-displaced fractures, 57.44% minimally displaced (≤2 mm) fractures, and 48.97% displaced fractures on RU images (p=0.045).

Conclusion: RU software accelerates fracture evaluation, while it has drawbacks including low sensitivity in fracture detection, false negativity, and underestimation of displacement.

Abstract Image

Abstract Image

Abstract Image

肋骨展开软件的利弊:创伤患者的可靠性和可重复性研究。
背景:在日常实践中,对24根肋骨的轴向CT片检查可能会成为一个空白,肋骨骨折(RF)很容易被忽视。肋骨展开(RU)是一种计算机辅助软件,承诺在二维计划中快速评估肋骨,以促进肋骨评估。我们的目的是评估RU软件用于CT射频检测的可靠性和可重复性,并确定RU应用的加速效应,以确定任何缺点。方法:以51例胸部外伤患者为研究对象,进行观察评估。该样本CT图像上rf的表征和分布由非观察者独立记录。关于RF的存在与否,CT图像由两名具有5年(观察者a)和18年(观察者b)胸椎放射学经验的放射科医生进行盲测评估。在非观察者的监督下,每个观察者在不同的日子评估轴向CT和RU图像。结果:22例患者共检测到113个RFs。观察者-服务器- a和观察者- b对轴向CT图像的平均评估时间分别为146.64 s和119.29 s。观察者a对RU图像的平均评价时间为66.44 s,观察者b的平均评价时间为32.66 s。与轴向CT图像评估相比,使用RU软件对观察者-A和观察者- b的评估周期有统计学意义上的减少(p结论:RU软件加速了骨折评估,但存在骨折检测灵敏度低、假阴性和低估位移等缺点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.40
自引率
18.20%
发文量
82
审稿时长
4-8 weeks
期刊介绍: The Turkish Journal of Trauma and Emergency Surgery (TJTES) is an official publication of the Turkish Association of Trauma and Emergency Surgery. It is a double-blind and peer-reviewed periodical that considers for publication clinical and experimental studies, case reports, technical contributions, and letters to the editor. Scope of the journal covers the trauma and emergency surgery. Each submission will be reviewed by at least two external, independent peer reviewers who are experts in their fields in order to ensure an unbiased evaluation process. The editorial board will invite an external and independent reviewer to manage the evaluation processes of manuscripts submitted by editors or by the editorial board members of the journal. The Editor in Chief is the final authority in the decision-making process for all submissions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信