{"title":"Multiphase preclinical assessment of a novel device to locate unintentionally retained surgical sharps: a proof-of-concept study.","authors":"Hae Sung Kang,&nbsp;Jad Khoraki,&nbsp;Jessie Gie,&nbsp;Dielle Duval,&nbsp;Susan Haynes,&nbsp;Michael Siev,&nbsp;Jay Shah,&nbsp;Fernando Kim,&nbsp;Martin Mangino,&nbsp;Levi Procter,&nbsp;Riccardo Autorino,&nbsp;Samuel Weprin","doi":"10.1186/s13037-023-00359-8","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Retained surgical sharps (RSS) is a \"never event\" that is preventable but may still occur despite of correct count and negative X-ray. This study assesses the feasibility of a novel device (\"Melzi Sharps Finder®\" or MSF) in effective detection of RSS.</p><p><strong>Methods: </strong>The first study consisted of determination of the presence of RSS or identification of RSS in an ex-vivo model (a container with hay in a laparoscopic trainer box). The second study consisted of determining presence of RSS in an in-vivo model (laparoscopy in live adult Yorkshire pigs) with 3 groups: C-arm, C-arm with MSF and MSF. The third study used similar apparatus though with laparotomy and included 2 groups: manual search and MSF.</p><p><strong>Results: </strong>In the first study, the MSF group had a higher rate of identification of a needle and decreased time to locate a needle versus control (98.1% vs. 22.0%, p < 0.001; 1.64 min ± 1.12vs. 3.34 min ± 1.28, p < 0.001). It also had increased accuracy of determining the presence of a needle and decreased time to reach this decision (100% vs. 58.8%, p < 0.001; 1.69 min ± 1.43 vs. 4.89 min ± 0.63, p < 0.001). In-the second study, the accuracy of determining the presence of a needle and time to reach this decision were comparable in each group (88.9% vs. 100% vs. 84.5%, p < 0.49; 2.2 min ± 2.2 vs. 2.7 min ± 2.1vs. 2.8 min ± 1.7, p = 0.68). In the third study, MSF group had higher accuracy in determining the presence of a needle and decreased time to reach this decision than the control (97.0% vs. 46.7%, p < 0.001; 2.0 min ± 1.5 vs. 3.9 min ± 1.4; p < 0.001). Multivariable analysis showed that MSF use was independently associated with an accurate determination of the presence of a needle (OR 12.1, p < 0.001).</p><p><strong>Conclusions: </strong>The use of MSF in this study's RSS models facilitated the determination of presence and localization of RSS as shown by the increased rate of identification of a needle, decreased time to identification and higher accuracy in determining the presence of a needle. This device may be used in conjunction with radiography as it gives live visual and auditory feedback for users during the search for RSS.</p>","PeriodicalId":46782,"journal":{"name":"Patient Safety in Surgery","volume":"17 1","pages":"10"},"PeriodicalIF":2.6000,"publicationDate":"2023-04-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10131432/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Patient Safety in Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s13037-023-00359-8","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Retained surgical sharps (RSS) is a "never event" that is preventable but may still occur despite of correct count and negative X-ray. This study assesses the feasibility of a novel device ("Melzi Sharps Finder®" or MSF) in effective detection of RSS.

Methods: The first study consisted of determination of the presence of RSS or identification of RSS in an ex-vivo model (a container with hay in a laparoscopic trainer box). The second study consisted of determining presence of RSS in an in-vivo model (laparoscopy in live adult Yorkshire pigs) with 3 groups: C-arm, C-arm with MSF and MSF. The third study used similar apparatus though with laparotomy and included 2 groups: manual search and MSF.

Results: In the first study, the MSF group had a higher rate of identification of a needle and decreased time to locate a needle versus control (98.1% vs. 22.0%, p < 0.001; 1.64 min ± 1.12vs. 3.34 min ± 1.28, p < 0.001). It also had increased accuracy of determining the presence of a needle and decreased time to reach this decision (100% vs. 58.8%, p < 0.001; 1.69 min ± 1.43 vs. 4.89 min ± 0.63, p < 0.001). In-the second study, the accuracy of determining the presence of a needle and time to reach this decision were comparable in each group (88.9% vs. 100% vs. 84.5%, p < 0.49; 2.2 min ± 2.2 vs. 2.7 min ± 2.1vs. 2.8 min ± 1.7, p = 0.68). In the third study, MSF group had higher accuracy in determining the presence of a needle and decreased time to reach this decision than the control (97.0% vs. 46.7%, p < 0.001; 2.0 min ± 1.5 vs. 3.9 min ± 1.4; p < 0.001). Multivariable analysis showed that MSF use was independently associated with an accurate determination of the presence of a needle (OR 12.1, p < 0.001).

Conclusions: The use of MSF in this study's RSS models facilitated the determination of presence and localization of RSS as shown by the increased rate of identification of a needle, decreased time to identification and higher accuracy in determining the presence of a needle. This device may be used in conjunction with radiography as it gives live visual and auditory feedback for users during the search for RSS.

Abstract Image

一种定位意外保留手术利器的新装置的多阶段临床前评估:一项概念验证研究。
背景:手术利器残留(RSS)是一种“从未发生过的事件”,尽管计数正确,x线阴性,但仍可能发生。本研究评估了一种新型设备(“Melzi Sharps Finder®”或MSF)在有效检测RSS方面的可行性。方法:第一项研究包括在离体模型(腹腔镜训练箱中装有干草的容器)中测定RSS的存在或识别RSS。第二项研究包括在活体模型(成年约克郡猪的腹腔镜检查)中测定RSS的存在,分为三组:c -臂、c -臂加MSF和MSF。第三项研究采用与剖腹手术相似的器械,包括人工搜索和MSF两组。结果:在第一项研究中,与对照组相比,MSF组对针的识别率更高,定位针的时间更短(98.1%对22.0%),p结论:在本研究的RSS模型中使用MSF有助于确定针的存在和定位,表现为针的识别率增加,识别时间缩短,确定针的存在的准确性更高。该设备可以与放射照相结合使用,因为它在搜索RSS期间为用户提供实时视觉和听觉反馈。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.80
自引率
8.10%
发文量
37
审稿时长
9 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信