Kazem Khiabani, Mohammad Hosein Amirzade-Iranaq, Ehsan Mostajeran
{"title":"Less Invasive Window Repositioning Technique for Sinus Floor Elevation: A Clinical and Radiographic Study","authors":"Kazem Khiabani, Mohammad Hosein Amirzade-Iranaq, Ehsan Mostajeran","doi":"10.11607/jomi.9570","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To determine whether a less invasive window repositioning technique could provide a feasible, safe, and reliable lateral sinus augmentation.</p><p><strong>Materials and methods: </strong>The less-invasive window repositioning technique using a piezoelectric saw was performed on adult patient candidates for lateral sinus floor elevation. The augmented bone height (primary outcome variable), bone length, and posthealing outcome variables were evaluated to determine the augmentation adequacy, safety, and reliability of this technique overall and in one- and two-implant groups with different window dimensions. Data were analyzed using descriptive statistics, chi-square test, and Pearson correlation analysis. P < .05 was considered significant.</p><p><strong>Results: </strong>A total of 50 consecutive sinus floor elevations with simultaneous placement of 66 implants (one-implant: 34, two-implant: 16) were performed on 44 subjects (72% men) with a mean age of 46.7 ± 10.3 years and followed for a mean of 13.28 ± 3.5 months. The overall, one-implant, and two-implant group mean window sizes were 31.38 ± 6.78 mm<sup>2</sup>, 28.38 ± 4.2 mm<sup>2</sup>, and 37.75 ± 6.88 mm<sup>2</sup>, respectively. The mean overall augmented bone height and length were 12.3 ± 1.04 mm and 19.67 ± 2.01 mm, respectively. The mean window size was significantly smaller in the one-implant group versus the two-implant group (P < .001). However, there was no correlation between window size and augmented bone height (r = -0.9, P = .54) and length (r = 0.05, P = .68). The posthealing outcome variables showed perfect window integration without soft tissue ingrowth. Six sinus perforations (12%) during membrane elevation that were not related to window osteotomy were observed and were appropriately managed.</p><p><strong>Conclusion: </strong>The less-invasive window repositioning technique is feasible, safe, and reliable for appropriate sinus augmentation in height and length. The reduction of window dimension does not influence the feasibility, augmentation adequacy, and surgical safety and does not increase surgical risks or membrane perforation. The repositioned window showed proper integration. Also, sinus floor elevation through this technique is an experience-based surgery that requires delicate instruments.</p>","PeriodicalId":50298,"journal":{"name":"International Journal of Oral & Maxillofacial Implants","volume":"38 2","pages":"303-312"},"PeriodicalIF":1.7000,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Oral & Maxillofacial Implants","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11607/jomi.9570","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: To determine whether a less invasive window repositioning technique could provide a feasible, safe, and reliable lateral sinus augmentation.
Materials and methods: The less-invasive window repositioning technique using a piezoelectric saw was performed on adult patient candidates for lateral sinus floor elevation. The augmented bone height (primary outcome variable), bone length, and posthealing outcome variables were evaluated to determine the augmentation adequacy, safety, and reliability of this technique overall and in one- and two-implant groups with different window dimensions. Data were analyzed using descriptive statistics, chi-square test, and Pearson correlation analysis. P < .05 was considered significant.
Results: A total of 50 consecutive sinus floor elevations with simultaneous placement of 66 implants (one-implant: 34, two-implant: 16) were performed on 44 subjects (72% men) with a mean age of 46.7 ± 10.3 years and followed for a mean of 13.28 ± 3.5 months. The overall, one-implant, and two-implant group mean window sizes were 31.38 ± 6.78 mm2, 28.38 ± 4.2 mm2, and 37.75 ± 6.88 mm2, respectively. The mean overall augmented bone height and length were 12.3 ± 1.04 mm and 19.67 ± 2.01 mm, respectively. The mean window size was significantly smaller in the one-implant group versus the two-implant group (P < .001). However, there was no correlation between window size and augmented bone height (r = -0.9, P = .54) and length (r = 0.05, P = .68). The posthealing outcome variables showed perfect window integration without soft tissue ingrowth. Six sinus perforations (12%) during membrane elevation that were not related to window osteotomy were observed and were appropriately managed.
Conclusion: The less-invasive window repositioning technique is feasible, safe, and reliable for appropriate sinus augmentation in height and length. The reduction of window dimension does not influence the feasibility, augmentation adequacy, and surgical safety and does not increase surgical risks or membrane perforation. The repositioned window showed proper integration. Also, sinus floor elevation through this technique is an experience-based surgery that requires delicate instruments.
期刊介绍:
Edited by Steven E. Eckert, DDS, MS ISSN (Print): 0882-2786
ISSN (Online): 1942-4434
This highly regarded, often-cited journal integrates clinical and scientific data to improve methods and results of oral and maxillofacial implant therapy. It presents pioneering research, technology, clinical applications, reviews of the literature, seminal studies, emerging technology, position papers, and consensus studies, as well as the many clinical and therapeutic innovations that ensue as a result of these efforts. The editorial board is composed of recognized opinion leaders in their respective areas of expertise and reflects the international reach of the journal. Under their leadership, JOMI maintains its strong scientific integrity while expanding its influence within the field of implant dentistry. JOMI’s popular regular feature "Thematic Abstract Review" presents a review of abstracts of recently published articles on a specific topical area of interest each issue.