Gian Huamán-Benancio, Carlos Peralta-Ponce, Daniella Vinelli-Arzubiaga, Cesar Esquivel-León, Isabel Pinedo Padilla
{"title":"[Outcomes of percutaneous balloon pulmonary valvuloplasty in pulmonary valve stenosis in the pediatric population in a single center, Lima - Peru].","authors":"Gian Huamán-Benancio, Carlos Peralta-Ponce, Daniella Vinelli-Arzubiaga, Cesar Esquivel-León, Isabel Pinedo Padilla","doi":"10.47487/apcyccv.v3i2.208","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To evaluate the effectiveness of the procedure and outcomes during follow-up.</p><p><strong>Methods: </strong>80 patients with pulmonary valvular stenosis who underwent percutaneous balloon valvuloplasty between January 2014 and December 2019 are described. Demographic, echocardiographic, and hemodynamic characteristics of the procedure were evaluated. Follow-up included clinical, echocardiographic parameters, pulmonary regurgitation severity, and residual pulmonary gradient at each cutoff point.</p><p><strong>Results: </strong>The age range was 2 years (interquartile range: 10.5 months - 6 years), and the predominant sex was male with 56.2%. The transvalvular pulmonary gradient decreased from 61.7 mmHg +- 21.2 to 17 mmHg (interquartile range: 11-26 mmHg). The immediate success rate was 90%. Follow-up time showed a median of 21 months (interquartile range: 5-47.5 months). All patients at follow-up showed some degree of pulmonary insufficiency at each cutoff point; 17% of the cases at the end of their follow-up were found to have severe insufficiency. Three cases of long-term restenosis were found (3.8%), and 6 (7.5%) were admitted for valvuloplasty surgery or pulmonary valve replacement. The complications reported reached 10% of cases, two patients were admitted to surgery during the procedure for major complications. A significant association was found with severe pulmonary insufficiency at the end of follow-up and ring/balloon ratio.</p><p><strong>Conclusions: </strong>Percutaneous transluminal valvuloplasty with balloon is an effective technique in the treatment of pulmonary valvular stenosis, with reported complications but with good results during follow-up.</p>","PeriodicalId":72295,"journal":{"name":"Archivos Peruanos de cardiologia y cirugia cardiovascular","volume":"3 2","pages":"60-68"},"PeriodicalIF":0.0000,"publicationDate":"2022-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/df/89/apcyccv-3-60.PMC10284577.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archivos Peruanos de cardiologia y cirugia cardiovascular","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47487/apcyccv.v3i2.208","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: To evaluate the effectiveness of the procedure and outcomes during follow-up.
Methods: 80 patients with pulmonary valvular stenosis who underwent percutaneous balloon valvuloplasty between January 2014 and December 2019 are described. Demographic, echocardiographic, and hemodynamic characteristics of the procedure were evaluated. Follow-up included clinical, echocardiographic parameters, pulmonary regurgitation severity, and residual pulmonary gradient at each cutoff point.
Results: The age range was 2 years (interquartile range: 10.5 months - 6 years), and the predominant sex was male with 56.2%. The transvalvular pulmonary gradient decreased from 61.7 mmHg +- 21.2 to 17 mmHg (interquartile range: 11-26 mmHg). The immediate success rate was 90%. Follow-up time showed a median of 21 months (interquartile range: 5-47.5 months). All patients at follow-up showed some degree of pulmonary insufficiency at each cutoff point; 17% of the cases at the end of their follow-up were found to have severe insufficiency. Three cases of long-term restenosis were found (3.8%), and 6 (7.5%) were admitted for valvuloplasty surgery or pulmonary valve replacement. The complications reported reached 10% of cases, two patients were admitted to surgery during the procedure for major complications. A significant association was found with severe pulmonary insufficiency at the end of follow-up and ring/balloon ratio.
Conclusions: Percutaneous transluminal valvuloplasty with balloon is an effective technique in the treatment of pulmonary valvular stenosis, with reported complications but with good results during follow-up.