Determination of microhardness of bulk-fill resins at different depths.

Analía B Garrofé, Mariana Picca, Andrea E Kaplan
{"title":"Determination of microhardness of bulk-fill resins at different depths.","authors":"Analía B Garrofé,&nbsp;Mariana Picca,&nbsp;Andrea E Kaplan","doi":"10.54589/aol.35/1/10","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of this study was to determine Vickers microhardness (HV) in bulk fill resins at different depths. Test specimens were prepared with different bulk fill resins: Filtek Bulk-Fill (3M ESPE) [FBF], Surefill SDR flow (Dentsply) [SDR], Fill-UP (COLTENE) [FU] and Surefill (Dentsply) [SF]. Semi-cylindrical test specimens were prepared in a mold 6 mm in diameter and 4 mm thick (n=5). A 1000 mW/cm2 light curing unit was applied (Coltolux LED - Coltene) for 20 seconds. HV was determined with three indentations (Vickers Future Tech FM300, 300 g, 8 s) at four depths: 1, 2, 3 and 4 mm from the top surface to the interior. Data were recorded immediately (t0) and 24 hours later (t24). Results were analyzed with two-way ANOVA (p<0.05), and multiple comparisons were performed using Tukey's test. Mean and SD of HV at t0 for each mm were: [FBF] t0: 49.23(4.65) / 48.32(3.36) / 44.38(2.06) / 40.59(2.58); [FBF] t24: 61.37(3.47) / 62.63(3.03) / 57.27(5.22) / 56.37(5.88);[SDR]t0:27.81(3.13) / 28.07(2.4) / 27.24(2.94) / 25.71(3.0); [SDR] t24: 35.11(2.16) / 35.17(1.96) / 35.53(1.81) / 33.18(2.08); [FU] t0: 41.43(1.41) / 39.87(0.88) / 38.11(1.81) / 39.09(1.92); [FU] t24: 49.27(1.54) / 48.77(1.77) / 48.65(1.88) / 46.76(4.93); [SF] t0: 71.35(7.09) / 67.39(9.76) / 68.95(6.21) / 64.1(8.35); [SF] t24: 76.06(6.61) / 75.31(9.37) / 75.2(11.57) / 69.81(12.14). ANOVA showed significant effect of material, depth and recording time (p<0.05), and Tukey's test showed that recording sites (depths) differed significantly, giving four homogeneous groups. Under the conditions of this study, it can be concluded that microhardness of bulk-fill resins can be affected by depth and post-curing time.</p>","PeriodicalId":7033,"journal":{"name":"Acta odontologica latinoamericana : AOL","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-04-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/bd/4b/1852-4834-35-1-10.PMC10283378.pdf","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta odontologica latinoamericana : AOL","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.54589/aol.35/1/10","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

The aim of this study was to determine Vickers microhardness (HV) in bulk fill resins at different depths. Test specimens were prepared with different bulk fill resins: Filtek Bulk-Fill (3M ESPE) [FBF], Surefill SDR flow (Dentsply) [SDR], Fill-UP (COLTENE) [FU] and Surefill (Dentsply) [SF]. Semi-cylindrical test specimens were prepared in a mold 6 mm in diameter and 4 mm thick (n=5). A 1000 mW/cm2 light curing unit was applied (Coltolux LED - Coltene) for 20 seconds. HV was determined with three indentations (Vickers Future Tech FM300, 300 g, 8 s) at four depths: 1, 2, 3 and 4 mm from the top surface to the interior. Data were recorded immediately (t0) and 24 hours later (t24). Results were analyzed with two-way ANOVA (p<0.05), and multiple comparisons were performed using Tukey's test. Mean and SD of HV at t0 for each mm were: [FBF] t0: 49.23(4.65) / 48.32(3.36) / 44.38(2.06) / 40.59(2.58); [FBF] t24: 61.37(3.47) / 62.63(3.03) / 57.27(5.22) / 56.37(5.88);[SDR]t0:27.81(3.13) / 28.07(2.4) / 27.24(2.94) / 25.71(3.0); [SDR] t24: 35.11(2.16) / 35.17(1.96) / 35.53(1.81) / 33.18(2.08); [FU] t0: 41.43(1.41) / 39.87(0.88) / 38.11(1.81) / 39.09(1.92); [FU] t24: 49.27(1.54) / 48.77(1.77) / 48.65(1.88) / 46.76(4.93); [SF] t0: 71.35(7.09) / 67.39(9.76) / 68.95(6.21) / 64.1(8.35); [SF] t24: 76.06(6.61) / 75.31(9.37) / 75.2(11.57) / 69.81(12.14). ANOVA showed significant effect of material, depth and recording time (p<0.05), and Tukey's test showed that recording sites (depths) differed significantly, giving four homogeneous groups. Under the conditions of this study, it can be concluded that microhardness of bulk-fill resins can be affected by depth and post-curing time.

Abstract Image

Abstract Image

Abstract Image

不同深度填充树脂显微硬度的测定。
本研究的目的是测定不同深度的大块填充树脂的维氏显微硬度(HV)。采用不同的散装填充树脂制备试样:Filtek bulk - fill (3M ESPE) [FBF]、sufill SDR flow (Dentsply) [SDR]、fill - fill (COLTENE) [FU]和sufill (Dentsply) [SF]。在直径为6mm、厚度为4mm的模具中制备半圆柱形试样(n=5)。使用1000mw /cm2的光固化装置(Coltolux LED - Coltene)固化20秒。用三个压痕(Vickers Future Tech FM300, 300 g, 8 s)在四个深度:从上表面到内部1,2,3和4mm处测定HV。即刻(t0)和24小时后(t24)分别记录数据。结果采用双因素方差分析(p
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信