Factors influencing the Shear Wave Elastography evaluation of the patellar tendon.

IF 1.8 4区 医学 Q2 ACOUSTICS
Michael Andrei Pelea, Oana Serban, Maria Badarinza, Roxana Rosca, Daniela Fodor
{"title":"Factors influencing the Shear Wave Elastography evaluation of the patellar tendon.","authors":"Michael Andrei Pelea,&nbsp;Oana Serban,&nbsp;Maria Badarinza,&nbsp;Roxana Rosca,&nbsp;Daniela Fodor","doi":"10.11152/mu-4193","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>There is no clear standardization for tendon Shear Wave Elastography (SWE), and data regarding the factors that influence the correctness of evaluation are scarce. We aimed to determine the intra- and interobserver agreement in patellar tendon SWE, and to establish the influence of various factors on elasticity values.</p><p><strong>Materials and methods: </strong>We recruited 37 healthy volunteers; SWE of the patellar tendon was performed by two examiners. The following factors were analyzed: probe frequency, degree of joint flexion, size of region of interest (ROI), distance of the color box from the probe footprint, utilization of coupling gel as standoff, and the effect of physical exercise on elastic modulus values.</p><p><strong>Results: </strong>Highest overall interobserver [k=0.767, 95%CI (0.717-0.799), p<0.001] and intraobserver agreement [k=0.920 (0.909-0.929) for examiner 1, k=0.891 (0.875-0.905) for examiner 2] was obtained with the knee in the neutral position, using the L18-5 probe. With the knee flexed at 30º and 45º, the elasticity values were higher compared to the neutral position (p<0.001). With the probe immersed in 0.25 and 0.50 cm coupling gel, the median values were lower compared to the probe placed on the skin (p=0.001, p=0.018). The ROI dimensions and the placement of the SWE box at the level of the skin or at 0.5 cm below skin did not significantly influence the elastic modulus. After physical exercise, the elasticity values decreased in the proximal and middle portion of the tendon (p=0.002, p<0.001).</p><p><strong>Conclusion: </strong>The best results obtained in patellar tendon SWE were with the knee in neutral position, in the proximal or middle tendon, after 10 minutes of relaxation and with the probe placed directly on the skin with minimal pressure. The size and position of ROI do not significantly influence the examination.</p>","PeriodicalId":48781,"journal":{"name":"Medical Ultrasonography","volume":"25 2","pages":"145-152"},"PeriodicalIF":1.8000,"publicationDate":"2023-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Ultrasonography","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11152/mu-4193","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 2

Abstract

Aim: There is no clear standardization for tendon Shear Wave Elastography (SWE), and data regarding the factors that influence the correctness of evaluation are scarce. We aimed to determine the intra- and interobserver agreement in patellar tendon SWE, and to establish the influence of various factors on elasticity values.

Materials and methods: We recruited 37 healthy volunteers; SWE of the patellar tendon was performed by two examiners. The following factors were analyzed: probe frequency, degree of joint flexion, size of region of interest (ROI), distance of the color box from the probe footprint, utilization of coupling gel as standoff, and the effect of physical exercise on elastic modulus values.

Results: Highest overall interobserver [k=0.767, 95%CI (0.717-0.799), p<0.001] and intraobserver agreement [k=0.920 (0.909-0.929) for examiner 1, k=0.891 (0.875-0.905) for examiner 2] was obtained with the knee in the neutral position, using the L18-5 probe. With the knee flexed at 30º and 45º, the elasticity values were higher compared to the neutral position (p<0.001). With the probe immersed in 0.25 and 0.50 cm coupling gel, the median values were lower compared to the probe placed on the skin (p=0.001, p=0.018). The ROI dimensions and the placement of the SWE box at the level of the skin or at 0.5 cm below skin did not significantly influence the elastic modulus. After physical exercise, the elasticity values decreased in the proximal and middle portion of the tendon (p=0.002, p<0.001).

Conclusion: The best results obtained in patellar tendon SWE were with the knee in neutral position, in the proximal or middle tendon, after 10 minutes of relaxation and with the probe placed directly on the skin with minimal pressure. The size and position of ROI do not significantly influence the examination.

影响髌腱剪切波弹性成像评价的因素。
目的:肌腱剪切波弹性成像(SWE)没有明确的标准化,影响评估正确性的因素也很少。我们的目的是确定髌骨肌腱SWE的观察者内部和观察者之间的一致性,并确定各种因素对弹性值的影响。材料与方法:招募健康志愿者37名;髌骨肌腱的SWE由两名检查人员进行。分析了探针频率、关节屈曲程度、感兴趣区域(ROI)大小、色盒与探针足迹的距离、偶联凝胶的使用以及体育锻炼对弹性模量值的影响。结果:整体观察者间最高[k=0.767, 95%CI (0.717-0.799)], p结论:髌骨肌腱SWE的最佳效果是膝关节处于中立位,在肌腱近端或中端放松10分钟后,探针直接放置在皮肤上,压力最小。ROI的大小和位置对检查无显著影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Medical Ultrasonography
Medical Ultrasonography RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
3.20
自引率
5.90%
发文量
79
期刊介绍: The journal aims to promote ultrasound diagnosis by publishing papers in a variety of categories, including editorial letters, original papers, review articles, pictorial essays, technical developments, case reports, letters to the editor or occasional special reports (fundamental, clinical as well as methodological and educational papers). The papers published cover the whole spectrum of the applications of diagnostic medical ultrasonography, including basic science and therapeutic applications. The journal hosts information regarding the society''s activities, scheduling of accredited training courses in ultrasound diagnosis, as well as the agenda of national and international scientific events.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信