Derek Y Chan, Daniel Cody Morris, Thomas J Polascik, Mark L Palmeri, Kathryn R Nightingale
{"title":"Combined ARFI and Shear Wave Imaging of Prostate Cancer: Optimizing Beam Sequences and Parameter Reconstruction Approaches.","authors":"Derek Y Chan, Daniel Cody Morris, Thomas J Polascik, Mark L Palmeri, Kathryn R Nightingale","doi":"10.1177/01617346231171895","DOIUrl":null,"url":null,"abstract":"<p><p>This study demonstrates the implementation of a shear wave reconstruction algorithm that enables concurrent acoustic radiation force impulse (ARFI) imaging and shear wave elasticity imaging (SWEI) of prostate cancer and zonal anatomy. The combined ARFI/SWEI sequence uses closely spaced push beams across the lateral field of view and simultaneously tracks both on-axis (within the region of excitation) and off-axis (laterally offset from the excitation) after each push beam. Using a large number of push beams across the lateral field of view enables the collection of higher signal-to-noise ratio (SNR) shear wave data to reconstruct the SWEI volume than is typically acquired. The shear wave arrival times were determined with cross-correlation of shear wave velocity signals in two dimensions after 3-D directional filtering to remove reflection artifacts. To combine data from serially interrogated lateral push locations, arrival times from different pushes were aligned by estimating the shear wave propagation time between push locations. Shear wave data acquired in an elasticity lesion phantom and reconstructed using this algorithm demonstrate benefits to contrast-to-noise ratio (CNR) with increased push beam density and 3-D directional filtering. Increasing the push beam spacing from 0.3 to 11.6 mm (typical for commercial SWEI systems) resulted in a 53% decrease in CNR. In human <i>in vivo</i> data, this imaging approach enabled high CNR (1.61-1.86) imaging of histologically-confirmed prostate cancer. The <i>in vivo</i> images had improved spatial resolution and CNR and fewer reflection artifacts as a result of the high push beam density, the high shear wave SNR, the use of multidimensional directional filtering, and the combination of shear wave data from different push beams.</p>","PeriodicalId":49401,"journal":{"name":"Ultrasonic Imaging","volume":null,"pages":null},"PeriodicalIF":2.5000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10660585/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasonic Imaging","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/01617346231171895","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/5/2 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0
Abstract
This study demonstrates the implementation of a shear wave reconstruction algorithm that enables concurrent acoustic radiation force impulse (ARFI) imaging and shear wave elasticity imaging (SWEI) of prostate cancer and zonal anatomy. The combined ARFI/SWEI sequence uses closely spaced push beams across the lateral field of view and simultaneously tracks both on-axis (within the region of excitation) and off-axis (laterally offset from the excitation) after each push beam. Using a large number of push beams across the lateral field of view enables the collection of higher signal-to-noise ratio (SNR) shear wave data to reconstruct the SWEI volume than is typically acquired. The shear wave arrival times were determined with cross-correlation of shear wave velocity signals in two dimensions after 3-D directional filtering to remove reflection artifacts. To combine data from serially interrogated lateral push locations, arrival times from different pushes were aligned by estimating the shear wave propagation time between push locations. Shear wave data acquired in an elasticity lesion phantom and reconstructed using this algorithm demonstrate benefits to contrast-to-noise ratio (CNR) with increased push beam density and 3-D directional filtering. Increasing the push beam spacing from 0.3 to 11.6 mm (typical for commercial SWEI systems) resulted in a 53% decrease in CNR. In human in vivo data, this imaging approach enabled high CNR (1.61-1.86) imaging of histologically-confirmed prostate cancer. The in vivo images had improved spatial resolution and CNR and fewer reflection artifacts as a result of the high push beam density, the high shear wave SNR, the use of multidimensional directional filtering, and the combination of shear wave data from different push beams.
期刊介绍:
Ultrasonic Imaging provides rapid publication for original and exceptional papers concerned with the development and application of ultrasonic-imaging technology. Ultrasonic Imaging publishes articles in the following areas: theoretical and experimental aspects of advanced methods and instrumentation for imaging