{"title":"Newly Developed Low Dose 180-degree CBCT Protocol Reduces Radiation Dose Without Compromising Diagnostic Value.","authors":"Afroditi Pita, Sejal Thacker, Takanori Sobue, Vaibhav Gandhi, Aditya Tadinada","doi":"10.11607/jomi.10364","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare the standard 360-degree CBCT acquisition protocol to the low dose 180-degree CBCT protocol for implant planning.</p><p><strong>Materials and methods: </strong>Two groups of patients, each consisting of 35 patients, were included in the study. The first group was imaged with the conventional 360-degree CBCT protocol, and the second group was imaged with the low dose 180-degree CBCT protocol. The primary outcome of this study was the number of scans that needed to be repeated due to poor image quality. In addition, six secondary parameters were evaluated quantitatively and qualitatively.</p><p><strong>Results: </strong>The results showed that there was no need to repeat any of the CBCT scans that were obtained in either group, which showed that 360-degree and 180-degree protocols had comparable image quality. As for the secondary parameters, the results showed that the evaluators were able to evaluate the six chosen parameters in a comparable manner.</p><p><strong>Conclusion: </strong>The 180-degree low dose CBCT scan is a viable option for dental implant treatment planning in the posterior mandible as it provides comparable and adequate information regarding accuracy of measurements, identification of critical structures, evaluation of bone quality, and any pathology.</p>","PeriodicalId":50298,"journal":{"name":"International Journal of Oral & Maxillofacial Implants","volume":" ","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2023-06-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Oral & Maxillofacial Implants","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11607/jomi.10364","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 1
Abstract
Purpose: To compare the standard 360-degree CBCT acquisition protocol to the low dose 180-degree CBCT protocol for implant planning.
Materials and methods: Two groups of patients, each consisting of 35 patients, were included in the study. The first group was imaged with the conventional 360-degree CBCT protocol, and the second group was imaged with the low dose 180-degree CBCT protocol. The primary outcome of this study was the number of scans that needed to be repeated due to poor image quality. In addition, six secondary parameters were evaluated quantitatively and qualitatively.
Results: The results showed that there was no need to repeat any of the CBCT scans that were obtained in either group, which showed that 360-degree and 180-degree protocols had comparable image quality. As for the secondary parameters, the results showed that the evaluators were able to evaluate the six chosen parameters in a comparable manner.
Conclusion: The 180-degree low dose CBCT scan is a viable option for dental implant treatment planning in the posterior mandible as it provides comparable and adequate information regarding accuracy of measurements, identification of critical structures, evaluation of bone quality, and any pathology.
期刊介绍:
Edited by Steven E. Eckert, DDS, MS ISSN (Print): 0882-2786
ISSN (Online): 1942-4434
This highly regarded, often-cited journal integrates clinical and scientific data to improve methods and results of oral and maxillofacial implant therapy. It presents pioneering research, technology, clinical applications, reviews of the literature, seminal studies, emerging technology, position papers, and consensus studies, as well as the many clinical and therapeutic innovations that ensue as a result of these efforts. The editorial board is composed of recognized opinion leaders in their respective areas of expertise and reflects the international reach of the journal. Under their leadership, JOMI maintains its strong scientific integrity while expanding its influence within the field of implant dentistry. JOMI’s popular regular feature "Thematic Abstract Review" presents a review of abstracts of recently published articles on a specific topical area of interest each issue.