Nitrous oxide occupational exposure in conscious sedation procedures in endoscopic ambulatories: a pilot retrospective observational study in an Italian hospital.

IF 0.4 Q3 Medicine
Ivan Borrelli, Roberta Pastorino, Paolo Emilio Santoro, Maria Rosaria Gualano, Maria Francesca Rossi, Rodolfo Buccico, Antongiulio Perrotta, Umberto Moscato
{"title":"Nitrous oxide occupational exposure in conscious sedation procedures in endoscopic ambulatories: a pilot retrospective observational study in an Italian hospital.","authors":"Ivan Borrelli, Roberta Pastorino, Paolo Emilio Santoro, Maria Rosaria Gualano, Maria Francesca Rossi, Rodolfo Buccico, Antongiulio Perrotta, Umberto Moscato","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Summary: </strong>Introduction. Nitrous oxide (N2O) is widely used to induce sedation also outside of operating rooms; there is a chance of workplace exposures for the operators engaged in the outpatient use of nitrous oxide. The aim of this research is to assess nitrous oxide exposure in gastroenterology outpatient settings. Methods. We performed an observational study marked by N2O environmental testing in a gastroenterology outpatient care; environmental research was supported by biological monitoring with urinary N2O analysis in exposed operators. The research was conducted both without and using a collective security device (NIKI mask). Results. The study was rolled out in 10 sessions of day shift procedures, totaling 4105 samples. The average N2O concentration in the environment was 27.58 (SD 1.76) and 449.59 (SD 35.29), respectively with and without NIKI Mask; the distribution of gases in the environment under investigation was not homogeneous (Anovatest P=0.001). Biological testing revealed a substantial rise in urinary concentration of 8.97 (p=0.001) between the start and the end of the shift, and the use of the NIKI-mask was effective (p=.003). Discussion. The exposure levels reported exceed the limits of 50 ppm (Italy operating rooms threshold value) as well as the value of 25 ppm (NIOSH threshold-value), indicating a significant issue in the outpatient use of N2O. Technical measures are needed to contain the occupational risk from N2O exposure outside of operating rooms; for the exposure results detected in this research, it is also evident that workers exposed to N2O must be subject to adequate health surveillance accounting for this occupational risk.</p>","PeriodicalId":12674,"journal":{"name":"Giornale italiano di medicina del lavoro ed ergonomia","volume":null,"pages":null},"PeriodicalIF":0.4000,"publicationDate":"2022-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Giornale italiano di medicina del lavoro ed ergonomia","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Summary: Introduction. Nitrous oxide (N2O) is widely used to induce sedation also outside of operating rooms; there is a chance of workplace exposures for the operators engaged in the outpatient use of nitrous oxide. The aim of this research is to assess nitrous oxide exposure in gastroenterology outpatient settings. Methods. We performed an observational study marked by N2O environmental testing in a gastroenterology outpatient care; environmental research was supported by biological monitoring with urinary N2O analysis in exposed operators. The research was conducted both without and using a collective security device (NIKI mask). Results. The study was rolled out in 10 sessions of day shift procedures, totaling 4105 samples. The average N2O concentration in the environment was 27.58 (SD 1.76) and 449.59 (SD 35.29), respectively with and without NIKI Mask; the distribution of gases in the environment under investigation was not homogeneous (Anovatest P=0.001). Biological testing revealed a substantial rise in urinary concentration of 8.97 (p=0.001) between the start and the end of the shift, and the use of the NIKI-mask was effective (p=.003). Discussion. The exposure levels reported exceed the limits of 50 ppm (Italy operating rooms threshold value) as well as the value of 25 ppm (NIOSH threshold-value), indicating a significant issue in the outpatient use of N2O. Technical measures are needed to contain the occupational risk from N2O exposure outside of operating rooms; for the exposure results detected in this research, it is also evident that workers exposed to N2O must be subject to adequate health surveillance accounting for this occupational risk.

内镜室有意识镇静程序中的一氧化二氮职业暴露:意大利一家医院的试点回顾性观察研究。
摘要:导言。一氧化二氮(N2O)在手术室外也被广泛用于诱导镇静;在门诊使用一氧化二氮的操作人员有可能在工作场所接触到一氧化二氮。本研究旨在评估胃肠病学门诊环境中的一氧化二氮暴露。方法。我们在胃肠病学门诊进行了一项观察性研究,以一氧化二氮环境测试为标志;通过对暴露操作人员进行尿液一氧化二氮分析的生物监测来支持环境研究。研究既在不使用集体安全装置(NIKI 面罩)的情况下进行,也在使用集体安全装置的情况下进行。结果。该研究共进行了 10 次白班程序,共采集了 4105 个样本。使用和不使用 NIKI 面罩时,环境中的一氧化二氮平均浓度分别为 27.58(标清 1.76)和 449.59(标清 35.29);调查环境中的气体分布不均匀(Anovatest P=0.001)。生物检测显示,在轮班开始和结束之间,尿液浓度大幅上升了 8.97(P=0.001),而使用 NIKI 面罩是有效的(P=.003)。讨论。报告的暴露水平超过了 50 ppm(意大利手术室阈值)和 25 ppm(美国国家职业健康安全与卫生研究院阈值)的限制,这表明在门诊使用一氧化二氮存在重大问题。需要采取技术措施来控制手术室外接触一氧化二氮的职业风险;就本研究中检测到的接触结果而言,接触一氧化二氮的工人显然必须接受充分的健康监测,以考虑到这种职业风险。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Giornale italiano di medicina del lavoro ed ergonomia
Giornale italiano di medicina del lavoro ed ergonomia PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH-
CiteScore
0.80
自引率
0.00%
发文量
10
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信