Yoon Seong Lee, Seunghyun Lee, Young Hun Choi, Yeon Jin Cho, Seul Bi Lee, Jung-Eun Cheon, Kyung Taek Hong, Hyoung Jin Kang
{"title":"Usefulness of two-dimensional shear wave elastography in diagnosing hepatic veno-occlusive disease in pediatric patients undergoing hematopoietic stem cell transplantation.","authors":"Yoon Seong Lee, Seunghyun Lee, Young Hun Choi, Yeon Jin Cho, Seul Bi Lee, Jung-Eun Cheon, Kyung Taek Hong, Hyoung Jin Kang","doi":"10.14366/usg.22107","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aimed to evaluate the usefulness of two-dimensional shear wave elastography (2D-SWE) in diagnosing hepatic veno-occlusive disease (VOD) in pediatric patients.</p><p><strong>Methods: </strong>This study retrospectively included pediatric patients who underwent hematopoietic stem cell transplantation (HSCT) between November 2019 and January 2021. All 34 patients (8.7±5.0 years) were examined using 2D-SWE for an initial diagnosis. A subgroup analysis was performed using the data from follow-up examinations of patients diagnosed with VOD. The characteristics of the initial VOD diagnosis were compared with the longitudinal changes observed in VOD patients who underwent multiple ultrasound examinations.</p><p><strong>Results: </strong>In total, 19 patients were diagnosed with VOD at 17.6±9.4 days after HSCT. All VOD patients showed hepatomegaly, ascites, and gallbladder wall thickening. Liver stiffness was higher in VOD patients than in non-VOD patients (12.4±1.1 vs. 6.3±0.8 kPa, P<0.001). Liver stiffness values above 7.2 kPa showed 84.2% sensitivity and 93.3% specificity in distinguishing VOD from non-VOD (area under the curve, 0.925; 95% confidence interval, 0.780 to 0.987; P<0.001). A subgroup analysis of 11 patients showed a linear decrease in liver stiffness values after VOD diagnosis with treatment (first, second, and third follow-ups; 13.5±1.7, 11.3±1.4, and 9.5±0.8 kPa, respectively), but without statistical significance in the pairwise analysis.</p><p><strong>Conclusion: </strong>Liver stiffness measured using 2D-SWE increased in pediatric patients who develop VOD after HSCT. Therefore, liver stiffness can be a predictive and quantitative parameter for diagnosing VOD.</p>","PeriodicalId":54227,"journal":{"name":"Ultrasonography","volume":null,"pages":null},"PeriodicalIF":2.4000,"publicationDate":"2023-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/ce/8d/usg-22107.PMC10071064.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasonography","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.14366/usg.22107","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: This study aimed to evaluate the usefulness of two-dimensional shear wave elastography (2D-SWE) in diagnosing hepatic veno-occlusive disease (VOD) in pediatric patients.
Methods: This study retrospectively included pediatric patients who underwent hematopoietic stem cell transplantation (HSCT) between November 2019 and January 2021. All 34 patients (8.7±5.0 years) were examined using 2D-SWE for an initial diagnosis. A subgroup analysis was performed using the data from follow-up examinations of patients diagnosed with VOD. The characteristics of the initial VOD diagnosis were compared with the longitudinal changes observed in VOD patients who underwent multiple ultrasound examinations.
Results: In total, 19 patients were diagnosed with VOD at 17.6±9.4 days after HSCT. All VOD patients showed hepatomegaly, ascites, and gallbladder wall thickening. Liver stiffness was higher in VOD patients than in non-VOD patients (12.4±1.1 vs. 6.3±0.8 kPa, P<0.001). Liver stiffness values above 7.2 kPa showed 84.2% sensitivity and 93.3% specificity in distinguishing VOD from non-VOD (area under the curve, 0.925; 95% confidence interval, 0.780 to 0.987; P<0.001). A subgroup analysis of 11 patients showed a linear decrease in liver stiffness values after VOD diagnosis with treatment (first, second, and third follow-ups; 13.5±1.7, 11.3±1.4, and 9.5±0.8 kPa, respectively), but without statistical significance in the pairwise analysis.
Conclusion: Liver stiffness measured using 2D-SWE increased in pediatric patients who develop VOD after HSCT. Therefore, liver stiffness can be a predictive and quantitative parameter for diagnosing VOD.
UltrasonographyMedicine-Radiology, Nuclear Medicine and Imaging
CiteScore
5.10
自引率
6.50%
发文量
78
审稿时长
15 weeks
期刊介绍:
Ultrasonography, the official English-language journal of the Korean Society of Ultrasound in Medicine (KSUM), is an international peer-reviewed academic journal dedicated to practice, research, technology, and education dealing with medical ultrasound. It is renamed from the Journal of Korean Society of Ultrasound in Medicine in January 2014, and published four times per year: January 1, April 1, July 1, and October 1. Original articles, technical notes, topical reviews, perspectives, pictorial essays, and timely editorial materials are published in Ultrasonography covering state-of-the-art content.
Ultrasonography aims to provide updated information on new diagnostic concepts and technical developments, including experimental animal studies using new equipment in addition to well-designed reviews of contemporary issues in patient care. Along with running KSUM Open, the annual international congress of KSUM, Ultrasonography also serves as a medium for cooperation among physicians and specialists from around the world who are focusing on various ultrasound technology and disease problems and relevant basic science.