Paul W. Barone , Flora J. Keumurian , Caleb Neufeld , Andrea Koenigsberg , Robert Kiss , James Leung , Michael Wiebe , Rima Ait-Belkacem , Chakameh Azimpour Tabrizi , Cristina Barbirato , Pascale Beurdeley , Audrey Brussel , Jean-Pol Cassart , Colette Cote , Noémie Deneyer , Veera Dheenadhayalan , Leyla Diaz , Angela Geiselhoeringer , Maria M. Gilleece , Jakob Goldmann , Stacy L. Springs
{"title":"Historical evaluation of the in vivo adventitious virus test and its potential for replacement with next generation sequencing (NGS)","authors":"Paul W. Barone , Flora J. Keumurian , Caleb Neufeld , Andrea Koenigsberg , Robert Kiss , James Leung , Michael Wiebe , Rima Ait-Belkacem , Chakameh Azimpour Tabrizi , Cristina Barbirato , Pascale Beurdeley , Audrey Brussel , Jean-Pol Cassart , Colette Cote , Noémie Deneyer , Veera Dheenadhayalan , Leyla Diaz , Angela Geiselhoeringer , Maria M. Gilleece , Jakob Goldmann , Stacy L. Springs","doi":"10.1016/j.biologicals.2022.11.003","DOIUrl":null,"url":null,"abstract":"<div><p>The Consortium on Adventitious Agent Contamination in Biomanufacturing (CAACB) collected historical data from 20 biopharmaceutical industry members on their experience with the <em>in vivo</em> adventitious virus test, the <em>in vitro</em> virus test, and the use of next generation sequencing (NGS) for viral safety. Over the past 20 years, only three positive <em>in vivo</em> adventitious virus test results were reported, and all were also detected in another concurrent assay. In more than three cases, data collected as a part of this study also found that the <em>in vivo</em> adventitious virus test had given a negative result for a sample that was later found to contain virus. Additionally, the <em>in vivo</em> adventitious virus test had experienced at least 21 false positives and had to be repeated an additional 21 times all while using more than 84,000 animals. These data support the consideration and need for alternative broad spectrum viral detection tests that are faster, more sensitive, more accurate, more specific, and more humane. NGS is one technology that may meet this need. Eighty one percent of survey respondents are either already actively using or exploring the use of NGS for viral safety. The risks and challenges of replacing <em>in vivo</em> adventitious virus testing with NGS are discussed. It is proposed to update the overall virus safety program for new biopharmaceutical products by replacing <em>in vivo</em> adventitious virus testing approaches with modern methodologies, such as NGS, that maintain or even improve the final safety of the product.</p></div>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2023-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"99","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S104510562200080X","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 4
Abstract
The Consortium on Adventitious Agent Contamination in Biomanufacturing (CAACB) collected historical data from 20 biopharmaceutical industry members on their experience with the in vivo adventitious virus test, the in vitro virus test, and the use of next generation sequencing (NGS) for viral safety. Over the past 20 years, only three positive in vivo adventitious virus test results were reported, and all were also detected in another concurrent assay. In more than three cases, data collected as a part of this study also found that the in vivo adventitious virus test had given a negative result for a sample that was later found to contain virus. Additionally, the in vivo adventitious virus test had experienced at least 21 false positives and had to be repeated an additional 21 times all while using more than 84,000 animals. These data support the consideration and need for alternative broad spectrum viral detection tests that are faster, more sensitive, more accurate, more specific, and more humane. NGS is one technology that may meet this need. Eighty one percent of survey respondents are either already actively using or exploring the use of NGS for viral safety. The risks and challenges of replacing in vivo adventitious virus testing with NGS are discussed. It is proposed to update the overall virus safety program for new biopharmaceutical products by replacing in vivo adventitious virus testing approaches with modern methodologies, such as NGS, that maintain or even improve the final safety of the product.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.