Common Designs of Custom-Made Fenestrated Arch Devices and Applicability of an Off-the-Shelf Design.

IF 1.7 2区 医学 Q3 PERIPHERAL VASCULAR DISEASE
Journal of Endovascular Therapy Pub Date : 2025-04-01 Epub Date: 2023-06-09 DOI:10.1177/15266028231179593
Ryan Gouveia E Melo, Carlota Fernández Prendes, Adib Khanafer, Anders Wanhainen, Kevin Mani, Guido Rouhani, Victor Chao, Kiang Hiong Tay, Tze Tec Chong, Donald Adam, Nuno Dias, Arzou Agaev, Nikolaos Tsilimparis
{"title":"Common Designs of Custom-Made Fenestrated Arch Devices and Applicability of an Off-the-Shelf Design.","authors":"Ryan Gouveia E Melo, Carlota Fernández Prendes, Adib Khanafer, Anders Wanhainen, Kevin Mani, Guido Rouhani, Victor Chao, Kiang Hiong Tay, Tze Tec Chong, Donald Adam, Nuno Dias, Arzou Agaev, Nikolaos Tsilimparis","doi":"10.1177/15266028231179593","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To analyze device designs, similarities and overlaps of custom-made fenestrated arch endografts intended for mid/distal arch thoracic endovascular aortic repair.</p><p><strong>Materials and methods: </strong>A multicenter cross-sectional study analyzing custom-made anonymized graft plans was performed. Graft plans were included from a cohort of mid/distal aortic arch repairs using custom-made fenestrated aortic endografts treated at 8 centers. Grafts targeting >2 arteries were excluded. No patient/clinical data were analyzed. A descriptive analysis was performed followed by an analysis of overlap of the designs to reach a common design in which the greatest number of grafts would overlap.</p><p><strong>Results: </strong>One hundred thirty-one graft plans were included. All grafts were custom-made grafts from the COOK Medical Fenestrated arch platform. Ninety-four (71.8%) had a scallop-and-single-fenestration design, 33 (25.2%) had a single fenestration and 4 (4.3%) a single scallop. For analysis purposes, these latter 4 grafts were excluded. Two main graft plans (<i>Plans 1 and 2</i>) were proposed after analysis with similar configuration (1 scallop with 30 mm width, 20 mm height, 12:00 position; 1 preloaded fenestration with 8 mm diameter, 26 mm from the top of the graft and 12:00 position; tapered, with a 193 mm length and 32 mm distal diameter) but with 2 different proximal diameters of 38 mm (<i>Plan 1</i>) and 44 mm (<i>Plan 2</i>), reaching an overall feasibility of 85.8% (n=109), being 47.2% (n=60) and 38.6% (n=49) for each design, respectively.</p><p><strong>Conclusion: </strong>The degree of overlap between the studied fenestrated and/or scalloped thoracic endovascular aneurysm repair (TEVAR) graft designs was high. Future studies analyzing these designs in a real-world cohort of patients are needed to further address off-the-shelf feasibility.Clinical ImpactIn a multicenter study analyzing 127 fenestrated aortic arch endograft plans from 9 aortic centers, we found that the degree of overlap between the studied fenestrated and/or scalloped arch graft designs was high and that 2 proposed graft designs would be theoretically applicable in 85.8% of cases. Future studies analyzing these designs in a real-world cohort of patients are needed to further address off-the-shelf feasibility.</p>","PeriodicalId":50210,"journal":{"name":"Journal of Endovascular Therapy","volume":" ","pages":"481-489"},"PeriodicalIF":1.7000,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11898388/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Endovascular Therapy","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15266028231179593","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/6/9 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: To analyze device designs, similarities and overlaps of custom-made fenestrated arch endografts intended for mid/distal arch thoracic endovascular aortic repair.

Materials and methods: A multicenter cross-sectional study analyzing custom-made anonymized graft plans was performed. Graft plans were included from a cohort of mid/distal aortic arch repairs using custom-made fenestrated aortic endografts treated at 8 centers. Grafts targeting >2 arteries were excluded. No patient/clinical data were analyzed. A descriptive analysis was performed followed by an analysis of overlap of the designs to reach a common design in which the greatest number of grafts would overlap.

Results: One hundred thirty-one graft plans were included. All grafts were custom-made grafts from the COOK Medical Fenestrated arch platform. Ninety-four (71.8%) had a scallop-and-single-fenestration design, 33 (25.2%) had a single fenestration and 4 (4.3%) a single scallop. For analysis purposes, these latter 4 grafts were excluded. Two main graft plans (Plans 1 and 2) were proposed after analysis with similar configuration (1 scallop with 30 mm width, 20 mm height, 12:00 position; 1 preloaded fenestration with 8 mm diameter, 26 mm from the top of the graft and 12:00 position; tapered, with a 193 mm length and 32 mm distal diameter) but with 2 different proximal diameters of 38 mm (Plan 1) and 44 mm (Plan 2), reaching an overall feasibility of 85.8% (n=109), being 47.2% (n=60) and 38.6% (n=49) for each design, respectively.

Conclusion: The degree of overlap between the studied fenestrated and/or scalloped thoracic endovascular aneurysm repair (TEVAR) graft designs was high. Future studies analyzing these designs in a real-world cohort of patients are needed to further address off-the-shelf feasibility.Clinical ImpactIn a multicenter study analyzing 127 fenestrated aortic arch endograft plans from 9 aortic centers, we found that the degree of overlap between the studied fenestrated and/or scalloped arch graft designs was high and that 2 proposed graft designs would be theoretically applicable in 85.8% of cases. Future studies analyzing these designs in a real-world cohort of patients are needed to further address off-the-shelf feasibility.

定制开窗拱装置的常见设计及现成设计的适用性。
目的:分析定制开窗弓内移植物用于中/远段胸弓血管内主动脉修复的装置设计、相似点和重叠点。材料和方法:一项多中心横断面研究分析了定制的匿名移植计划。移植计划包括在8个中心使用定制开窗主动脉内移植物修复中/远端主动脉弓的队列。排除针对>2条动脉的移植物。未分析患者/临床资料。进行描述性分析,然后分析设计的重叠,以达到最大数量的移植物重叠的共同设计。结果:共纳入131个移植方案。所有移植物均为库克医疗开窗弓平台定制移植物。94个(71.8%)为扇贝-单开窗设计,33个(25.2%)为单开窗设计,4个(4.3%)为单扇贝设计。为了分析的目的,后4个移植物被排除在外。经过分析,提出了两种主要的嫁接方案(方案1和方案2),配置相似(1个扇贝,宽30 mm,高20 mm,位置12:00;预压开窗1个,直径8mm,距接穗顶部26mm,位置12:00;锥形,长度为193 mm,远端直径为32 mm),但近端直径分别为38 mm(方案1)和44 mm(方案2),每种设计的总体可行性分别为85.8% (n=109), 47.2% (n=60)和38.6% (n=49)。结论:所研究的开窗和/或扇形胸腔血管内动脉瘤修复(TEVAR)移植设计之间的重叠程度很高。未来的研究需要在现实世界的患者队列中分析这些设计,以进一步解决现成的可行性。临床影响:在一项多中心研究中,我们分析了来自9个主动脉中心的127个开窗主动脉弓内移植物方案,我们发现所研究的开窗和/或扇形主动脉弓移植物设计之间的重叠程度很高,两种提出的移植物设计在理论上适用于85.8%的病例。未来的研究需要在现实世界的患者队列中分析这些设计,以进一步解决现成的可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.30
自引率
15.40%
发文量
203
审稿时长
6-12 weeks
期刊介绍: The Journal of Endovascular Therapy (formerly the Journal of Endovascular Surgery) was established in 1994 as a forum for all physicians, scientists, and allied healthcare professionals who are engaged or interested in peripheral endovascular techniques and technology. An official publication of the International Society of Endovascular Specialists (ISEVS), the Journal of Endovascular Therapy publishes peer-reviewed articles of interest to clinicians and researchers in the field of peripheral endovascular interventions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信