Biomechanical and Histologic Evaluation of Osseointegration of Titanium Dental Implants Modified by Various Combinations of Sandblasting, Acid-Etching, Hydroxyapatite, and Hyaluronic Acid Coating Techniques.
{"title":"Biomechanical and Histologic Evaluation of Osseointegration of Titanium Dental Implants Modified by Various Combinations of Sandblasting, Acid-Etching, Hydroxyapatite, and Hyaluronic Acid Coating Techniques.","authors":"Emre Yurttutan, Ömür Dereci, Mine Alkaya Karagöz","doi":"10.11607/jomi.9935","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare the osseointegration process of the titanium dental implants with five different surface characteristics-sandblasted, sandblasted and acid-etched, hyaluronic acid-coated (HYA), hydroxyapatite-coated (HA), and machined-in an experimental sheep model at 1- and 3-month examinations.</p><p><strong>Materials and methods: </strong>One hundred sixty dental implants were placed in the left and right tibias of 16 sheep. Five experimental groups were designed. Eight animals (80 implants) were used for biomechanical tests of reverse torque analysis and resonance frequency analysis (RFA). Eight of them (80 implants) were used for the evaluation of bone-to-implant contact (BIC) percentage in histomorphometric analysis. Forty of 80 implants (8 implants for each group) were used at 1-month examinations, and the remaining 40 (8 implants for each group) implants were used at 3-month examinations in the biomechanical test group and histomorphometric examination group, separately.</p><p><strong>Results: </strong>Intergroup analysis at the 3-month followup showed that the increase in the implant stability quotient (ISQ) value was statistically significant for only the HYA group (<i>P</i> < .05). According to ISQ values at 1 and 3 months, group HYA showed statistically higher values at the 1 and 3-month examinations (<i>P</i> < .05). Groups HYA and HA had statistically higher reverse torque values than other groups at the 1-month examination (<i>P</i> < .05). At the 3-month evaluation, the HYA group showed significantly higher reverse torque values compared to other groups (<i>P</i> < .05). The BIC values of the sandblasted and acid-etched, HYA, and HA groups were significantly higher than the sandblasted and machined groups at the 1- and 3-month examinations (<i>P</i> < .05). The BIC value for the HA group showed decreased value at the 3-month examination compared to the 1-month examination (<i>P</i> < .05).</p><p><strong>Conclusion: </strong>The RFA, reverse torque, and histomorphometric analysis at 1- and 3-month examinations show that dental implants coated with HYA may have increased potential for osseointegration compared to dental implants with sandblasted, sandblasted and acid-etched, machined, and HA-coated surfaces. Int J Oral Maxillofac Implants 2023;38:583-590. doi: 10.11607/jomi.9935.</p>","PeriodicalId":50298,"journal":{"name":"International Journal of Oral & Maxillofacial Implants","volume":"38 3","pages":"583-590"},"PeriodicalIF":1.7000,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Oral & Maxillofacial Implants","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11607/jomi.9935","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: To compare the osseointegration process of the titanium dental implants with five different surface characteristics-sandblasted, sandblasted and acid-etched, hyaluronic acid-coated (HYA), hydroxyapatite-coated (HA), and machined-in an experimental sheep model at 1- and 3-month examinations.
Materials and methods: One hundred sixty dental implants were placed in the left and right tibias of 16 sheep. Five experimental groups were designed. Eight animals (80 implants) were used for biomechanical tests of reverse torque analysis and resonance frequency analysis (RFA). Eight of them (80 implants) were used for the evaluation of bone-to-implant contact (BIC) percentage in histomorphometric analysis. Forty of 80 implants (8 implants for each group) were used at 1-month examinations, and the remaining 40 (8 implants for each group) implants were used at 3-month examinations in the biomechanical test group and histomorphometric examination group, separately.
Results: Intergroup analysis at the 3-month followup showed that the increase in the implant stability quotient (ISQ) value was statistically significant for only the HYA group (P < .05). According to ISQ values at 1 and 3 months, group HYA showed statistically higher values at the 1 and 3-month examinations (P < .05). Groups HYA and HA had statistically higher reverse torque values than other groups at the 1-month examination (P < .05). At the 3-month evaluation, the HYA group showed significantly higher reverse torque values compared to other groups (P < .05). The BIC values of the sandblasted and acid-etched, HYA, and HA groups were significantly higher than the sandblasted and machined groups at the 1- and 3-month examinations (P < .05). The BIC value for the HA group showed decreased value at the 3-month examination compared to the 1-month examination (P < .05).
Conclusion: The RFA, reverse torque, and histomorphometric analysis at 1- and 3-month examinations show that dental implants coated with HYA may have increased potential for osseointegration compared to dental implants with sandblasted, sandblasted and acid-etched, machined, and HA-coated surfaces. Int J Oral Maxillofac Implants 2023;38:583-590. doi: 10.11607/jomi.9935.
期刊介绍:
Edited by Steven E. Eckert, DDS, MS ISSN (Print): 0882-2786
ISSN (Online): 1942-4434
This highly regarded, often-cited journal integrates clinical and scientific data to improve methods and results of oral and maxillofacial implant therapy. It presents pioneering research, technology, clinical applications, reviews of the literature, seminal studies, emerging technology, position papers, and consensus studies, as well as the many clinical and therapeutic innovations that ensue as a result of these efforts. The editorial board is composed of recognized opinion leaders in their respective areas of expertise and reflects the international reach of the journal. Under their leadership, JOMI maintains its strong scientific integrity while expanding its influence within the field of implant dentistry. JOMI’s popular regular feature "Thematic Abstract Review" presents a review of abstracts of recently published articles on a specific topical area of interest each issue.