Michele Stocchero, Yohei Jinno, Marco Toia, Marianne Ahmad, Silvia Galli, Evaggelia Papia, Manjula Herath, Jonas P Becktor
{"title":"Effect of Drilling Preparation on Immediately Loaded Implants: An In Vivo Study in Sheep.","authors":"Michele Stocchero, Yohei Jinno, Marco Toia, Marianne Ahmad, Silvia Galli, Evaggelia Papia, Manjula Herath, Jonas P Becktor","doi":"10.11607/jomi.9949","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To determine the biologic and biomechanical effects of two implant drilling protocols on the cortical bone around implants subjected to immediate loading.</p><p><strong>Materials and methods: </strong>A total of 48 implants were inserted into the mandibles of six sheep following one of two drilling protocols: undersized preparation (US; n = 24) and nonundersized preparation (NUS; n = 24). Immediately after implant insertion, an abutment was placed on each implant and 36 implants were subjected to 10 sessions of dynamic vertical loads (1,500 cycles, 1 Hz) of 25 N or 50 N. Insertion torque value (ITV) was recorded at implant installation. Resonance frequency analysis (RFA) was measured at implant insertion and at each loading session. Fluorochrome was administered at day 17, and the animals were euthanized after 5 weeks. The removal torque values (RTVs) were measured, and samples underwent histomorphometric, μCT (microcomputed tomography), and fluorescence image acquisition analyses. The bone volume density (BV/TV), bone-to-implant contact (BIC), bone area fraction occupancy (BAFO), and fluorochrome stained bone surface (MS) were calculated. A linear mixed model analysis was performed, and Pearson paired correlation was calculated.</p><p><strong>Results: </strong>Five implants from the NUS group failed, with a mean ITV of 8.8 Ncm and an RFA value of 57. The mean ITVs for US group and NUS group were 80.5 (± 14) Ncm and 45.9 (± 25) Ncm, respectively (<i>P</i> < .001). No differences were noted in the RFA values from the time of implant insertion until the end of the study. No differences in RTV, BV/TV, BAFO, or MS were observed between the groups. Intense new bone formation took place in the NUS group implants that were subjected to load.</p><p><strong>Conclusions: </strong>Undersized preparation of cortical bone ensured a greater BIC compared to a nonundersized preparation. Moreover, this study demonstrated that immediate loading did not interfere with the osseointegration process, but loading induced intense new bone formation in the NUS group. It is not recommended to immediately load the implants when the clinically perceived primary stability is lower than an ITV of 10 Ncm and an RFA value of 60. Int J Oral Maxillofac Implants 2023;38:607-618. doi: 10.11607/jomi.9949.</p>","PeriodicalId":50298,"journal":{"name":"International Journal of Oral & Maxillofacial Implants","volume":"38 3","pages":"607-618"},"PeriodicalIF":1.7000,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Oral & Maxillofacial Implants","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11607/jomi.9949","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 1
Abstract
Purpose: To determine the biologic and biomechanical effects of two implant drilling protocols on the cortical bone around implants subjected to immediate loading.
Materials and methods: A total of 48 implants were inserted into the mandibles of six sheep following one of two drilling protocols: undersized preparation (US; n = 24) and nonundersized preparation (NUS; n = 24). Immediately after implant insertion, an abutment was placed on each implant and 36 implants were subjected to 10 sessions of dynamic vertical loads (1,500 cycles, 1 Hz) of 25 N or 50 N. Insertion torque value (ITV) was recorded at implant installation. Resonance frequency analysis (RFA) was measured at implant insertion and at each loading session. Fluorochrome was administered at day 17, and the animals were euthanized after 5 weeks. The removal torque values (RTVs) were measured, and samples underwent histomorphometric, μCT (microcomputed tomography), and fluorescence image acquisition analyses. The bone volume density (BV/TV), bone-to-implant contact (BIC), bone area fraction occupancy (BAFO), and fluorochrome stained bone surface (MS) were calculated. A linear mixed model analysis was performed, and Pearson paired correlation was calculated.
Results: Five implants from the NUS group failed, with a mean ITV of 8.8 Ncm and an RFA value of 57. The mean ITVs for US group and NUS group were 80.5 (± 14) Ncm and 45.9 (± 25) Ncm, respectively (P < .001). No differences were noted in the RFA values from the time of implant insertion until the end of the study. No differences in RTV, BV/TV, BAFO, or MS were observed between the groups. Intense new bone formation took place in the NUS group implants that were subjected to load.
Conclusions: Undersized preparation of cortical bone ensured a greater BIC compared to a nonundersized preparation. Moreover, this study demonstrated that immediate loading did not interfere with the osseointegration process, but loading induced intense new bone formation in the NUS group. It is not recommended to immediately load the implants when the clinically perceived primary stability is lower than an ITV of 10 Ncm and an RFA value of 60. Int J Oral Maxillofac Implants 2023;38:607-618. doi: 10.11607/jomi.9949.
期刊介绍:
Edited by Steven E. Eckert, DDS, MS ISSN (Print): 0882-2786
ISSN (Online): 1942-4434
This highly regarded, often-cited journal integrates clinical and scientific data to improve methods and results of oral and maxillofacial implant therapy. It presents pioneering research, technology, clinical applications, reviews of the literature, seminal studies, emerging technology, position papers, and consensus studies, as well as the many clinical and therapeutic innovations that ensue as a result of these efforts. The editorial board is composed of recognized opinion leaders in their respective areas of expertise and reflects the international reach of the journal. Under their leadership, JOMI maintains its strong scientific integrity while expanding its influence within the field of implant dentistry. JOMI’s popular regular feature "Thematic Abstract Review" presents a review of abstracts of recently published articles on a specific topical area of interest each issue.