Effect of Drilling Preparation on Immediately Loaded Implants: An In Vivo Study in Sheep.

IF 1.7 4区 医学 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
Michele Stocchero, Yohei Jinno, Marco Toia, Marianne Ahmad, Silvia Galli, Evaggelia Papia, Manjula Herath, Jonas P Becktor
{"title":"Effect of Drilling Preparation on Immediately Loaded Implants: An In Vivo Study in Sheep.","authors":"Michele Stocchero,&nbsp;Yohei Jinno,&nbsp;Marco Toia,&nbsp;Marianne Ahmad,&nbsp;Silvia Galli,&nbsp;Evaggelia Papia,&nbsp;Manjula Herath,&nbsp;Jonas P Becktor","doi":"10.11607/jomi.9949","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To determine the biologic and biomechanical effects of two implant drilling protocols on the cortical bone around implants subjected to immediate loading.</p><p><strong>Materials and methods: </strong>A total of 48 implants were inserted into the mandibles of six sheep following one of two drilling protocols: undersized preparation (US; n = 24) and nonundersized preparation (NUS; n = 24). Immediately after implant insertion, an abutment was placed on each implant and 36 implants were subjected to 10 sessions of dynamic vertical loads (1,500 cycles, 1 Hz) of 25 N or 50 N. Insertion torque value (ITV) was recorded at implant installation. Resonance frequency analysis (RFA) was measured at implant insertion and at each loading session. Fluorochrome was administered at day 17, and the animals were euthanized after 5 weeks. The removal torque values (RTVs) were measured, and samples underwent histomorphometric, μCT (microcomputed tomography), and fluorescence image acquisition analyses. The bone volume density (BV/TV), bone-to-implant contact (BIC), bone area fraction occupancy (BAFO), and fluorochrome stained bone surface (MS) were calculated. A linear mixed model analysis was performed, and Pearson paired correlation was calculated.</p><p><strong>Results: </strong>Five implants from the NUS group failed, with a mean ITV of 8.8 Ncm and an RFA value of 57. The mean ITVs for US group and NUS group were 80.5 (± 14) Ncm and 45.9 (± 25) Ncm, respectively (<i>P</i> < .001). No differences were noted in the RFA values from the time of implant insertion until the end of the study. No differences in RTV, BV/TV, BAFO, or MS were observed between the groups. Intense new bone formation took place in the NUS group implants that were subjected to load.</p><p><strong>Conclusions: </strong>Undersized preparation of cortical bone ensured a greater BIC compared to a nonundersized preparation. Moreover, this study demonstrated that immediate loading did not interfere with the osseointegration process, but loading induced intense new bone formation in the NUS group. It is not recommended to immediately load the implants when the clinically perceived primary stability is lower than an ITV of 10 Ncm and an RFA value of 60. Int J Oral Maxillofac Implants 2023;38:607-618. doi: 10.11607/jomi.9949.</p>","PeriodicalId":50298,"journal":{"name":"International Journal of Oral & Maxillofacial Implants","volume":"38 3","pages":"607-618"},"PeriodicalIF":1.7000,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Oral & Maxillofacial Implants","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11607/jomi.9949","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 1

Abstract

Purpose: To determine the biologic and biomechanical effects of two implant drilling protocols on the cortical bone around implants subjected to immediate loading.

Materials and methods: A total of 48 implants were inserted into the mandibles of six sheep following one of two drilling protocols: undersized preparation (US; n = 24) and nonundersized preparation (NUS; n = 24). Immediately after implant insertion, an abutment was placed on each implant and 36 implants were subjected to 10 sessions of dynamic vertical loads (1,500 cycles, 1 Hz) of 25 N or 50 N. Insertion torque value (ITV) was recorded at implant installation. Resonance frequency analysis (RFA) was measured at implant insertion and at each loading session. Fluorochrome was administered at day 17, and the animals were euthanized after 5 weeks. The removal torque values (RTVs) were measured, and samples underwent histomorphometric, μCT (microcomputed tomography), and fluorescence image acquisition analyses. The bone volume density (BV/TV), bone-to-implant contact (BIC), bone area fraction occupancy (BAFO), and fluorochrome stained bone surface (MS) were calculated. A linear mixed model analysis was performed, and Pearson paired correlation was calculated.

Results: Five implants from the NUS group failed, with a mean ITV of 8.8 Ncm and an RFA value of 57. The mean ITVs for US group and NUS group were 80.5 (± 14) Ncm and 45.9 (± 25) Ncm, respectively (P < .001). No differences were noted in the RFA values from the time of implant insertion until the end of the study. No differences in RTV, BV/TV, BAFO, or MS were observed between the groups. Intense new bone formation took place in the NUS group implants that were subjected to load.

Conclusions: Undersized preparation of cortical bone ensured a greater BIC compared to a nonundersized preparation. Moreover, this study demonstrated that immediate loading did not interfere with the osseointegration process, but loading induced intense new bone formation in the NUS group. It is not recommended to immediately load the implants when the clinically perceived primary stability is lower than an ITV of 10 Ncm and an RFA value of 60. Int J Oral Maxillofac Implants 2023;38:607-618. doi: 10.11607/jomi.9949.

钻孔准备对即刻加载植入物的影响:绵羊体内研究。
目的:探讨两种种植体钻孔方案对种植体周围即刻载荷下皮质骨的生物学和生物力学影响。材料和方法:共有48个植入物按照两种钻孔方案中的一种植入6只羊的下颌骨:小尺寸准备(US;n = 24)和非小尺寸制剂(NUS;N = 24)。植入种植体后立即在每个种植体上放置一个基台,36个种植体承受10次25 N或50 N的动态垂直载荷(1500个周期,1 Hz),在种植体安装时记录插入扭矩值(ITV)。在植入时和每次加载时测量共振频率分析(RFA)。第17天给予荧光染料,5周后安乐死。测量去除扭矩值(RTVs),并对样品进行组织形态学、微计算机断层扫描(μCT)和荧光图像采集分析。计算骨体积密度(BV/TV)、骨与种植体接触(BIC)、骨面积占比(BAFO)和荧光染色骨表面(MS)。进行线性混合模型分析,并计算Pearson配对相关性。结果:NUS组5例种植体失败,平均ITV为8.8 Ncm, RFA值为57。US组和NUS组的平均tvv分别为80.5(±14)Ncm和45.9(±25)Ncm (P < 0.001)。从植入时间到研究结束,RFA值没有差异。RTV、BV/TV、BAFO、MS组间无差异。在承受载荷的NUS组植入物中发生了强烈的新骨形成。结论:皮质骨的小尺寸制备比非小尺寸制备确保了更大的BIC。此外,本研究表明,立即加载不会干扰骨整合过程,但在NUS组中,加载诱导了强烈的新骨形成。当临床感知的初级稳定性低于10 Ncm的ITV和60的RFA值时,不建议立即加载植入物。口腔颌面种植学[J]; 2009;38(1): 557 - 561。doi: 10.11607 / jomi.9949。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.30
自引率
5.00%
发文量
115
审稿时长
6 months
期刊介绍: Edited by Steven E. Eckert, DDS, MS ISSN (Print): 0882-2786 ISSN (Online): 1942-4434 This highly regarded, often-cited journal integrates clinical and scientific data to improve methods and results of oral and maxillofacial implant therapy. It presents pioneering research, technology, clinical applications, reviews of the literature, seminal studies, emerging technology, position papers, and consensus studies, as well as the many clinical and therapeutic innovations that ensue as a result of these efforts. The editorial board is composed of recognized opinion leaders in their respective areas of expertise and reflects the international reach of the journal. Under their leadership, JOMI maintains its strong scientific integrity while expanding its influence within the field of implant dentistry. JOMI’s popular regular feature "Thematic Abstract Review" presents a review of abstracts of recently published articles on a specific topical area of interest each issue.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信