Fiona-Leandra Zaugg, Samir Abou-Ayash, Pedro Molinero-Mourelle, Vinicius Rizzo-Marques, Martin Schimmel, Julia-Gabriela Wittneben
{"title":"Distortion assessment of different materials in full-arch dentate impressions in relation to operator experience: a comparative in vivo.","authors":"Fiona-Leandra Zaugg, Samir Abou-Ayash, Pedro Molinero-Mourelle, Vinicius Rizzo-Marques, Martin Schimmel, Julia-Gabriela Wittneben","doi":"10.11607/ijp.8555","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Evaluating the distortion probability in impressions of completely dentate arches when different impression materials are used in relation to operator experience.</p><p><strong>Material and methods: </strong>Twenty-eight students (group A) and 7 dentists (group B) performed 3 maxillary impressions on 28 students (participants), each using vinyl siloxane ether (VSE), polyether (PE), and irreversible hydrocolloid (IHC). Gypsum master casts were fabricated and subsequently digitized. Intraoral scans were taken as a control. Differences between master casts and intraoral scans were visualized by heatmaps and planar deviations were investigated. If planar deviations of >120 μm were found, the impression was rated as \"distorted.\" An additional superimposition using the casts from VSE or PE was performed to confirm the presence of distortions. The relative number of surfaces with distortions in each impression was calculated. The procedure was repeated for a distortion threshold of 500 μm. The statistical analyses included measures ANOVA and post-hoc tests (a < 0.05).</p><p><strong>Results: </strong>When 120 μm was considered as the threshold for distortions, IHC impressions showed higher distortion probability than PE impressions in group A (<i>P</i> = 0.003) and group B (<i>P</i> < 0.0001). In group B only, PE showed a lower distortion probability than VSE (<i>P</i> = 0.02). There was no difference between the study groups (<i>P</i> = 0.42). Considering 500 μm as a threshold for distortions, there was no difference between impression materials (<i>P</i> = 0.17) or study groups (<i>P</i> = 0.53).</p><p><strong>Conclusion: </strong>There were no statistic significant differences in relation to operator experience. Different impression materials had a significant impact on distortion probability. Polyether impressions showed the lowest distortion probability. Int J Prosthodont. 10.11607/ijp.8555.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":" ","pages":""},"PeriodicalIF":2.1000,"publicationDate":"2023-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Prosthodontics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11607/ijp.8555","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: Evaluating the distortion probability in impressions of completely dentate arches when different impression materials are used in relation to operator experience.
Material and methods: Twenty-eight students (group A) and 7 dentists (group B) performed 3 maxillary impressions on 28 students (participants), each using vinyl siloxane ether (VSE), polyether (PE), and irreversible hydrocolloid (IHC). Gypsum master casts were fabricated and subsequently digitized. Intraoral scans were taken as a control. Differences between master casts and intraoral scans were visualized by heatmaps and planar deviations were investigated. If planar deviations of >120 μm were found, the impression was rated as "distorted." An additional superimposition using the casts from VSE or PE was performed to confirm the presence of distortions. The relative number of surfaces with distortions in each impression was calculated. The procedure was repeated for a distortion threshold of 500 μm. The statistical analyses included measures ANOVA and post-hoc tests (a < 0.05).
Results: When 120 μm was considered as the threshold for distortions, IHC impressions showed higher distortion probability than PE impressions in group A (P = 0.003) and group B (P < 0.0001). In group B only, PE showed a lower distortion probability than VSE (P = 0.02). There was no difference between the study groups (P = 0.42). Considering 500 μm as a threshold for distortions, there was no difference between impression materials (P = 0.17) or study groups (P = 0.53).
Conclusion: There were no statistic significant differences in relation to operator experience. Different impression materials had a significant impact on distortion probability. Polyether impressions showed the lowest distortion probability. Int J Prosthodont. 10.11607/ijp.8555.
期刊介绍:
Official Journal of the European Association for Osseointegration (EAO), the International College of Prosthodontists (ICP), the German Society of Prosthodontics and Dental Materials Science (DGPro), and the Italian Academy of Prosthetic Dentistry (AIOP)
Prosthodontics demands a clinical research emphasis on patient- and dentist-mediated concerns in the management of oral rehabilitation needs. It is about making and implementing the best clinical decisions to enhance patients'' quality of life via applied biologic architecture - a role that far exceeds that of traditional prosthetic dentistry, with its emphasis on materials and techniques. The International Journal of Prosthodontics is dedicated to exploring and developing this conceptual shift in the role of today''s prosthodontist, clinician, and educator alike. The editorial board is composed of a distinguished team of leading international scholars.