{"title":"Euthanasia of Neonatal Rats and Mice using Carbon Monoxide.","authors":"Debra L Hickman","doi":"10.30802/AALAS-JAALAS-22-000103","DOIUrl":null,"url":null,"abstract":"<p><p>Minimization of potential pain and distress of rodents undergoing euthanasia is a touchstone of veterinary clinical medicine. Evaluation of this issue in postweanling rodents has supported revisions to the AVMA (American Veterinary Medical Association) Guidelines on Euthanasia in 2020. However, relatively little information is available on humane aspects of anesthesia and euthanasia in neonatal mice and rats. These neonates are not reliably euthanized by exposure to commonly used inhalant anesthetic agents due to their physiologic adaptations to hypercapnic environments. Therefore, options such as prolonged inhalant anesthetic gas exposure, decapitation, or use of injectable anesthetics are recommended for neonates. All of these recommended methods have operational implications, ranging from reported job dissatisfaction by animal care staff to rigorous reporting requirements associated with the use of controlled substances. This lack of a euthanasia method that does not entail operational issues hampers the ability of veterinary professionals to provide appropriate guidance to scientists working with neonates. This study was designed to assess the effectiveness of carbon monoxide (CO) as an alternative euthanasia agent for mouse and rat pups on postnatal days (PND) 0 to 12. The study demonstrates that CO may be a potential alternative for preweanling mice and rats at PND6 or older but is not appropriate for neonates at PND5 or younger.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10230535/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.30802/AALAS-JAALAS-22-000103","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

Minimization of potential pain and distress of rodents undergoing euthanasia is a touchstone of veterinary clinical medicine. Evaluation of this issue in postweanling rodents has supported revisions to the AVMA (American Veterinary Medical Association) Guidelines on Euthanasia in 2020. However, relatively little information is available on humane aspects of anesthesia and euthanasia in neonatal mice and rats. These neonates are not reliably euthanized by exposure to commonly used inhalant anesthetic agents due to their physiologic adaptations to hypercapnic environments. Therefore, options such as prolonged inhalant anesthetic gas exposure, decapitation, or use of injectable anesthetics are recommended for neonates. All of these recommended methods have operational implications, ranging from reported job dissatisfaction by animal care staff to rigorous reporting requirements associated with the use of controlled substances. This lack of a euthanasia method that does not entail operational issues hampers the ability of veterinary professionals to provide appropriate guidance to scientists working with neonates. This study was designed to assess the effectiveness of carbon monoxide (CO) as an alternative euthanasia agent for mouse and rat pups on postnatal days (PND) 0 to 12. The study demonstrates that CO may be a potential alternative for preweanling mice and rats at PND6 or older but is not appropriate for neonates at PND5 or younger.

使用一氧化碳对新生大鼠和小鼠进行安乐死。
最大限度地减少接受安乐死的啮齿动物的潜在痛苦是兽医临床医学的试金石。对断奶后啮齿动物这一问题的评估支持了2020年对AVMA(美国兽医协会)安乐死指南的修订。然而,关于新生小鼠和大鼠麻醉和安乐死的人道方面的信息相对较少。由于这些新生儿对高碳酸血症环境的生理适应,接触常用的吸入性麻醉剂并不能可靠地对其实施安乐死。因此,建议新生儿选择长期吸入麻醉气体、斩首或使用注射麻醉剂。所有这些建议的方法都具有操作意义,从动物护理人员报告的工作不满到与使用受控物质相关的严格报告要求。缺乏一种不涉及操作问题的安乐死方法,阻碍了兽医专业人员为从事新生儿研究的科学家提供适当指导的能力。本研究旨在评估一氧化碳(CO)在出生后0至12天(PND)作为小鼠和大鼠幼崽的替代安乐死剂的有效性。该研究表明,CO可能是断奶前小鼠和PND6或以上大鼠的潜在替代品,但不适合PND5或以下的新生儿。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信