Frontotemporal Craniotomy for Clipping of Unruptured Aneurysm Using a Diamond-Coated Thread Wire Saw and Reconstruction Using Calcium Phosphate Cement without Metal Fixation.

IF 1.3 Q3 SURGERY
Hiroyuki Koizumi, Daisuke Yamamoto, Hajime Handa, Wakiko Saruta, Satoru Shimizu, Takuichiro Hide, Toshihiro Kumabe
{"title":"Frontotemporal Craniotomy for Clipping of Unruptured Aneurysm Using a Diamond-Coated Thread Wire Saw and Reconstruction Using Calcium Phosphate Cement without Metal Fixation.","authors":"Hiroyuki Koizumi,&nbsp;Daisuke Yamamoto,&nbsp;Hajime Handa,&nbsp;Wakiko Saruta,&nbsp;Satoru Shimizu,&nbsp;Takuichiro Hide,&nbsp;Toshihiro Kumabe","doi":"10.1055/s-0042-1758543","DOIUrl":null,"url":null,"abstract":"<p><p>Metal fixation systems for cranial bone flaps cut by a drill are convenient devices for cranioplasty, but cause several complications. We use modified craniotomy using a fine diamond-coated threadwire saw (diamond T-saw) to reduce the bone defect, and osteoplasty calcium phosphate cement without metal fixation. We report our outcomes and tips of this method. A total of 78 consecutive patients underwent elective frontotemporal craniotomy for clipping of unruptured intracranial aneurysms between 2015 and 2019. The follow-up periods ranged from 13 to 66 months. The bone fixation state was evaluated by bone computed tomography (CT) and three-dimensional CT (3D-CT). The diamond T-saw could minimize the bone defect. Only one wound infection occurred within 1 week postoperatively, and no late infection. No pain, palpable/cosmetically noticeable displacement of the bone flap, fluid accumulations, or other complications were observed. The condition of bone fixation and the cosmetic efficacy were thoroughly satisfactory for all patients, and bone CT and 3D-CT demonstrated that good bone fusion. No complication typical of metal fixation occurred. Our method is technically easy and safety, and achieved good mid-term bone flap fixation in the mid-term course, so has potential for bone fixation without the use of metal plates.</p>","PeriodicalId":47543,"journal":{"name":"Archives of Plastic Surgery-APS","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/72/4a/10-1055-s-0042-1758543.PMC10226794.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of Plastic Surgery-APS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0042-1758543","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Metal fixation systems for cranial bone flaps cut by a drill are convenient devices for cranioplasty, but cause several complications. We use modified craniotomy using a fine diamond-coated threadwire saw (diamond T-saw) to reduce the bone defect, and osteoplasty calcium phosphate cement without metal fixation. We report our outcomes and tips of this method. A total of 78 consecutive patients underwent elective frontotemporal craniotomy for clipping of unruptured intracranial aneurysms between 2015 and 2019. The follow-up periods ranged from 13 to 66 months. The bone fixation state was evaluated by bone computed tomography (CT) and three-dimensional CT (3D-CT). The diamond T-saw could minimize the bone defect. Only one wound infection occurred within 1 week postoperatively, and no late infection. No pain, palpable/cosmetically noticeable displacement of the bone flap, fluid accumulations, or other complications were observed. The condition of bone fixation and the cosmetic efficacy were thoroughly satisfactory for all patients, and bone CT and 3D-CT demonstrated that good bone fusion. No complication typical of metal fixation occurred. Our method is technically easy and safety, and achieved good mid-term bone flap fixation in the mid-term course, so has potential for bone fixation without the use of metal plates.

Abstract Image

Abstract Image

Abstract Image

额颞开颅应用金刚石包覆线锯夹持未破裂动脉瘤及不带金属固定的磷酸钙水泥重建。
颅骨骨瓣的金属固定系统是颅骨成形术中方便的设备,但会引起一些并发症。我们采用改良开颅术,使用精细金刚石涂层线锯(金刚石t形锯)来减少骨缺损,骨成形术不使用金属固定磷酸钙骨水泥。我们报告了这种方法的结果和提示。2015年至2019年期间,共有78名连续患者接受了选择性额颞叶开颅术,以夹闭未破裂的颅内动脉瘤。随访时间为13至66个月。采用骨计算机断层扫描(CT)和三维CT (3D-CT)评估骨固定状态。金刚石t形锯可以最大限度地减少骨缺损。术后1周内仅有1例创面感染,无后期感染。未观察到疼痛、可触及/美观的骨瓣移位、积液或其他并发症。所有患者的骨固定情况和美容效果完全满意,骨CT和3D-CT显示骨融合良好。无典型金属固定并发症发生。该方法技术简单、安全,中期骨瓣固定效果良好,具有不使用金属板固定的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.10
自引率
6.70%
发文量
131
审稿时长
10 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信