An assessment of the impact of adhesive coverage and wire type on fixed retainer failures and force propagation along two types of orthodontic retainer wires: an in vitro study.

IF 3 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Selena H M Tee, Saroash Shahid, Dalya Al-Moghrabi, Padhraig S Fleming
{"title":"An assessment of the impact of adhesive coverage and wire type on fixed retainer failures and force propagation along two types of orthodontic retainer wires: an in vitro study.","authors":"Selena H M Tee, Saroash Shahid, Dalya Al-Moghrabi, Padhraig S Fleming","doi":"10.2319/110722-765.1","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To evaluate the force required to promote the failure of fixed orthodontic retainers with different adhesive (composite) coverage and to assess the presence and extent of force propagation with two different orthodontic retainer wires.</p><p><strong>Materials and methods: </strong>Ortho-FlexTech and Ortho-Care Perform (0.0175 inches), each of 15-cm length, were bonded on acrylic blocks with different adhesive surface diameters (2 mm, 3 mm, 4 mm, and 5 mm). The samples (n = 160) were subjected to a tensile pull-out test, and debonding force was recorded. Fixed retainers using two different wires and 4-mm adhesive diameter were bonded on acrylic bases resembling a maxillary dental arch (n = 72). The retainers were loaded occluso-apically until the first sign of failure while being video recorded. Individual frames of the recordings were extracted and compared. A force propagation scoring index was developed to quantify the extent of force transmission under load.</p><p><strong>Results: </strong>A 4-mm adhesive surface diameter required the highest debonding force for both retainer wires with significant differences compared with 2 mm (P < .001; 95% confidence interval [CI]: 8.69, 21.69) and 3 mm (P = .026; 95% CI: 0.60, 13.59). Force propagation scores were significantly higher for Ortho-Care Perform.</p><p><strong>Conclusions: </strong>Based on this laboratory-based assessment, consideration should be given to the fabrication of maxillary fixed retainers using a minimum of 4-mm diameter composite coverage on each tooth. Force appeared to propagate more readily with Ortho-Care Perform than with a flexible chain alternative. This may risk stress accumulation at the terminal ends with potential for associated unwanted tooth movement in the presence of intact fixed retainers.</p>","PeriodicalId":50790,"journal":{"name":"Angle Orthodontist","volume":null,"pages":null},"PeriodicalIF":3.0000,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10633805/pdf/","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Angle Orthodontist","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2319/110722-765.1","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 1

Abstract

Objectives: To evaluate the force required to promote the failure of fixed orthodontic retainers with different adhesive (composite) coverage and to assess the presence and extent of force propagation with two different orthodontic retainer wires.

Materials and methods: Ortho-FlexTech and Ortho-Care Perform (0.0175 inches), each of 15-cm length, were bonded on acrylic blocks with different adhesive surface diameters (2 mm, 3 mm, 4 mm, and 5 mm). The samples (n = 160) were subjected to a tensile pull-out test, and debonding force was recorded. Fixed retainers using two different wires and 4-mm adhesive diameter were bonded on acrylic bases resembling a maxillary dental arch (n = 72). The retainers were loaded occluso-apically until the first sign of failure while being video recorded. Individual frames of the recordings were extracted and compared. A force propagation scoring index was developed to quantify the extent of force transmission under load.

Results: A 4-mm adhesive surface diameter required the highest debonding force for both retainer wires with significant differences compared with 2 mm (P < .001; 95% confidence interval [CI]: 8.69, 21.69) and 3 mm (P = .026; 95% CI: 0.60, 13.59). Force propagation scores were significantly higher for Ortho-Care Perform.

Conclusions: Based on this laboratory-based assessment, consideration should be given to the fabrication of maxillary fixed retainers using a minimum of 4-mm diameter composite coverage on each tooth. Force appeared to propagate more readily with Ortho-Care Perform than with a flexible chain alternative. This may risk stress accumulation at the terminal ends with potential for associated unwanted tooth movement in the presence of intact fixed retainers.

粘合剂覆盖和金属丝类型对固定固位器失效和沿两种类型的正畸固位器金属丝的力传播的影响的评估:一项体外研究。
目的:评估不同粘合剂(复合材料)覆盖率的固定正畸固位器导致失效所需的力,并评估两种不同正畸固位丝的力传播的存在和程度。材料和方法:将Ortho FlexTech和Ortho Care Perform(0.0175英寸)分别粘合在具有不同粘合表面直径(2毫米、3毫米、4毫米和5毫米)的丙烯酸块上,长度为15厘米。对样品(n=160)进行拉伸拉拔试验,并记录脱粘力。使用两种不同的金属丝和4mm粘合剂直径的固定保持器结合在类似上颌牙弓的丙烯酸基底上(n=72)。在视频记录时,保持器被咬合顶部加载,直到出现第一个失效迹象。提取并比较记录的各个帧。开发了一个力传播评分指数来量化载荷下的力传递程度。结果:4mm的粘合剂表面直径对两种固位钢丝的脱粘力要求最高,与2mm(P<.001;95%置信区间[CI]:8.69,21.69)和3mm(P=.026;95%CI:0.60,13.59)相比存在显著差异。Ortho Care Perform的力传播得分显著更高。结论:基于此实验室评估,应考虑在每颗牙齿上使用直径至少为4mm的复合覆盖物来制造上颌固定固位器。与柔性链替代品相比,Ortho Care Perform似乎更容易传播力。在存在完整固定保持器的情况下,这可能会导致应力在末端积聚,并可能导致相关的不必要的牙齿移动。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Angle Orthodontist
Angle Orthodontist 医学-牙科与口腔外科
CiteScore
6.40
自引率
5.90%
发文量
95
审稿时长
3 months
期刊介绍: The Angle Orthodontist is the official publication of the Edward H. Angle Society of Orthodontists and is published bimonthly in January, March, May, July, September and November by The EH Angle Education and Research Foundation Inc. The Angle Orthodontist is the only major journal in orthodontics with a non-commercial, non-profit publisher -- The E. H. Angle Education and Research Foundation. We value our freedom to operate exclusively in the best interests of our readers and authors. Our website www.angle.org is completely free and open to all visitors.
文献相关原料
公司名称 产品信息 采购帮参考价格
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信