Arthroscopic treatment of tibial intercondylar eminence fractures in skeletally immature patients with bioabsorbable nails.

Q3 Medicine
Francesco M Uboldi, Paolo Trezza, Elena Panuccio, Antonio Memeo
{"title":"Arthroscopic treatment of tibial intercondylar eminence fractures in skeletally immature patients with bioabsorbable nails.","authors":"Francesco M Uboldi,&nbsp;Paolo Trezza,&nbsp;Elena Panuccio,&nbsp;Antonio Memeo","doi":"10.4081/pmc.2022.299","DOIUrl":null,"url":null,"abstract":"<p><p>Fractures involving tibial eminence caused by ACL avulsion lesion most frequently occur paediatric patients. Satisfactory reduction in displaced fractures cannot be achieved through conservative treatment, while arthroscopy-assisted fixation technique represents the gold standard to reduce and to fix articular fractures and several effective implants have been used to treat this kind of fractures. In our retrospective study, we proposed a different arthroscopic technique to fix Type II and Type III tibial eminence fractures by using bioabsorbable nails. Nineteen patients, aged 6 to 13 years were treated with arthroscopic reduction and fixation of the fragment using bioabsorbable nails. At 6-month follow-up, all patients showed a decrease of less than 2mm of the anterior edge. All patients at maximum follow-up reached a full knee flexion/extension. IKDC subjective mean score at six-month was 88.14.2 points (range 80-95; p<0.01). For what concerns the Tegner Activity Scale, the mean value of 5.51 (range 3-7) prior to the surgery changed into 5.10.9 (range 3-6) at 6 months. No inflammatory reactions were reported and all fractures healed without complications. The objective IKDC grade A was reported in 18 patients and grade B in one patient, having a \"nearly normal\" range of motion item (92% compared to contralateral). Results can be compared to other surgical procedures described in the literature, having the same fast learning curve increase and limited complications, beside the fact that a second operation for metallic implants removal was avoided.</p>","PeriodicalId":35535,"journal":{"name":"Pediatria Medica e Chirurgica","volume":"44 s1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pediatria Medica e Chirurgica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4081/pmc.2022.299","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Fractures involving tibial eminence caused by ACL avulsion lesion most frequently occur paediatric patients. Satisfactory reduction in displaced fractures cannot be achieved through conservative treatment, while arthroscopy-assisted fixation technique represents the gold standard to reduce and to fix articular fractures and several effective implants have been used to treat this kind of fractures. In our retrospective study, we proposed a different arthroscopic technique to fix Type II and Type III tibial eminence fractures by using bioabsorbable nails. Nineteen patients, aged 6 to 13 years were treated with arthroscopic reduction and fixation of the fragment using bioabsorbable nails. At 6-month follow-up, all patients showed a decrease of less than 2mm of the anterior edge. All patients at maximum follow-up reached a full knee flexion/extension. IKDC subjective mean score at six-month was 88.14.2 points (range 80-95; p<0.01). For what concerns the Tegner Activity Scale, the mean value of 5.51 (range 3-7) prior to the surgery changed into 5.10.9 (range 3-6) at 6 months. No inflammatory reactions were reported and all fractures healed without complications. The objective IKDC grade A was reported in 18 patients and grade B in one patient, having a "nearly normal" range of motion item (92% compared to contralateral). Results can be compared to other surgical procedures described in the literature, having the same fast learning curve increase and limited complications, beside the fact that a second operation for metallic implants removal was avoided.

关节镜下生物可吸收钉治疗骨未成熟患者胫骨髁间隆起骨折。
前交叉韧带撕脱伤致胫隆起骨折多见于儿科患者。移位性骨折不能通过保守治疗达到满意复位,而关节镜辅助固定技术是复位和固定关节骨折的金标准,已有几种有效的植入物用于治疗此类骨折。在我们的回顾性研究中,我们提出了一种不同的关节镜技术,使用生物可吸收钉固定II型和III型胫骨隆起骨折。19例6至13岁的患者采用关节镜下复位和生物可吸收钉固定碎片。在6个月的随访中,所有患者均显示前缘下降小于2mm。所有患者在最大随访时间内均达到膝关节完全屈伸。六个月IKDC主观平均得分为88.14.2分(范围80-95;p
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Pediatria Medica e Chirurgica
Pediatria Medica e Chirurgica Medicine-Pediatrics, Perinatology and Child Health
CiteScore
0.70
自引率
0.00%
发文量
21
审稿时长
10 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信