{"title":"Reference intervals and method sensitivity for electrocardiology, hemodynamics, and body temperature parameters in healthy cynomolgus monkeys","authors":"Xiefan Fang, Stephen D. Tichenor","doi":"10.1016/j.vascn.2022.107247","DOIUrl":null,"url":null,"abstract":"<div><p>In nonclinical studies, electrocardiograms (ECG) of cynomolgus monkey are recorded intermittently by external leads in manually restrained animals (snapshot recording) or continuously by jacketed external telemetry (JET) or implanted radiotelemetry transmitter in freely moving animals. With the implanted device, blood pressure and core body temperature can be monitored simultaneously. Despite the frequent use of cynomolgus monkeys in nonclinical safety pharmacology testing, few reference data are available for this species, comparisons of the ECG recording methods are limited, and power analyses are seldom conducted. In this study, pretreatment data were recorded from 406, 663, and 131 healthy experimentally naïve monkeys using the snapshot, JET, and implantable method, respectively, from 2019 to 2021. Reference intervals were determined for ECG, blood pressure, and body temperature parameters. Diurnal effects were observed in these parameters, with the exception of QRS and pulse pressure. The QRS, QT, and heart rate-corrected QTc intervals, as well as blood pressure, had a weak positive relationship with age and/or body weight. There were no sex differences in these parameters, and the country of origin only had minimal influences. Compared to telemetry, snapshot ECG data had shorter RR, PR, and QT intervals and longer QRS interval. The JET and implanted telemetry ECG data were comparable. Effect size analysis was conducted to estimate the method sensitivity for each parameter in common non-clinical study design scenarios. Snapshot recording, JET, and implanted telemetry were sensitive to detect 7–15 milliseconds of changes in QTc intervals in standard study designs, indicating these are powerful methods for assessment of QT prolongation in vivo.</p></div>","PeriodicalId":16767,"journal":{"name":"Journal of pharmacological and toxicological methods","volume":"120 ","pages":"Article 107247"},"PeriodicalIF":1.3000,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of pharmacological and toxicological methods","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1056871922000946","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 1
Abstract
In nonclinical studies, electrocardiograms (ECG) of cynomolgus monkey are recorded intermittently by external leads in manually restrained animals (snapshot recording) or continuously by jacketed external telemetry (JET) or implanted radiotelemetry transmitter in freely moving animals. With the implanted device, blood pressure and core body temperature can be monitored simultaneously. Despite the frequent use of cynomolgus monkeys in nonclinical safety pharmacology testing, few reference data are available for this species, comparisons of the ECG recording methods are limited, and power analyses are seldom conducted. In this study, pretreatment data were recorded from 406, 663, and 131 healthy experimentally naïve monkeys using the snapshot, JET, and implantable method, respectively, from 2019 to 2021. Reference intervals were determined for ECG, blood pressure, and body temperature parameters. Diurnal effects were observed in these parameters, with the exception of QRS and pulse pressure. The QRS, QT, and heart rate-corrected QTc intervals, as well as blood pressure, had a weak positive relationship with age and/or body weight. There were no sex differences in these parameters, and the country of origin only had minimal influences. Compared to telemetry, snapshot ECG data had shorter RR, PR, and QT intervals and longer QRS interval. The JET and implanted telemetry ECG data were comparable. Effect size analysis was conducted to estimate the method sensitivity for each parameter in common non-clinical study design scenarios. Snapshot recording, JET, and implanted telemetry were sensitive to detect 7–15 milliseconds of changes in QTc intervals in standard study designs, indicating these are powerful methods for assessment of QT prolongation in vivo.
期刊介绍:
Journal of Pharmacological and Toxicological Methods publishes original articles on current methods of investigation used in pharmacology and toxicology. Pharmacology and toxicology are defined in the broadest sense, referring to actions of drugs and chemicals on all living systems. With its international editorial board and noted contributors, Journal of Pharmacological and Toxicological Methods is the leading journal devoted exclusively to experimental procedures used by pharmacologists and toxicologists.