{"title":"Test-Retest Reliability, Effects of Age and Comparison of Horizontal 2 Semicircular Canals Gain Values between Head Impulse and Suppression Head Impulse Paradigms.","authors":"Sharifah Zainon Sayed,&nbsp;Nor Haniza Abdul Wahat,&nbsp;Azman Ali Raymond,&nbsp;Norhayati Hussein,&nbsp;Marniza Omar","doi":"10.5152/iao.2023.21387","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>This study investigates the test-retest reliability, aging effects, and differences in horizontal semicircular canals gain values between the head impulse paradigm and suppression head impulse paradigm.</p><p><strong>Methods: </strong>Sixty healthy adult subjects aged 22-76-year-old (mean ± standard deviation=47.27 ± 18.29) participated in the head impulse paradigm and suppression head impulse paradigm using the video head impulse test. The Head impulse paradigm was used to assess all 6 semicircular canals, while suppression head impulse paradigm measured only the horizontal canals. Twenty subjects aged 22-40-year-old (25.25 ± 4.9) underwent a second session for the test-retest reliability.</p><p><strong>Results: </strong>There were good test-retest reliability for both measures (right horizontal head impulse paradigm, intraclass correlation coefficient=0.80; left horizontal head impulse paradigm, intraclass correlation coefficient=0.77; right anterior head impulse paradigm, intraclass correlation coefficient=0.86; left anterior head impulse paradigm, intraclass correlation coefficient=0.78; right posterior head impulse paradigm, intraclass correlation coefficient=0.78; left posterior head impulse paradigm, intraclass correlation coefficient=0.75; right horizontal suppression head impulse paradigm, intraclass correlation coefficient=0.76; left horizontal suppression head impulse paradigm, intraclass correlation coefficient=0.79). The test-retest reliability for suppression head impulse paradigmanti-compensatory saccade latency and amplitude were moderate (right latency, intraclass correlation coefficient=0.61; left latency, intraclass correlation coefficient=0.69; right amplitude, intraclass correlation coefficient=0.69; left amplitude, intraclass correlation coefficient=0.58). There were no significant effects of age on head impulse paradigm and suppression head impulse paradigm vestibulo-ocular reflex gain values and suppression head impulse paradigmsaccade latency. However, the saccade amplitude became smaller with increasing age, P < .001. The horizontal suppression head impulse paradigm vestibuloocular reflex gain values were significantly lower than the head impulse paradigm for both sides (right, P = .004; left, P = .004).</p><p><strong>Conclusion: </strong>There was good test-retest reliability for both measures, and the gain values stabilized with age. However, suppression head impulse paradigm anti-compensatory saccade latency and amplitude had lower test-retest reliability than the gain. The suppression head impulse paradigm vestibulo-ocular reflex gain was lower than the head impulse paradigm and its anti-compensatory saccade amplitude reduced with increasing age.</p>","PeriodicalId":54793,"journal":{"name":"Journal of International Advanced Otology","volume":"19 1","pages":"33-40"},"PeriodicalIF":1.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/48/d4/jiao-19-1-33.PMC9984981.pdf","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of International Advanced Otology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5152/iao.2023.21387","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 1

Abstract

Background: This study investigates the test-retest reliability, aging effects, and differences in horizontal semicircular canals gain values between the head impulse paradigm and suppression head impulse paradigm.

Methods: Sixty healthy adult subjects aged 22-76-year-old (mean ± standard deviation=47.27 ± 18.29) participated in the head impulse paradigm and suppression head impulse paradigm using the video head impulse test. The Head impulse paradigm was used to assess all 6 semicircular canals, while suppression head impulse paradigm measured only the horizontal canals. Twenty subjects aged 22-40-year-old (25.25 ± 4.9) underwent a second session for the test-retest reliability.

Results: There were good test-retest reliability for both measures (right horizontal head impulse paradigm, intraclass correlation coefficient=0.80; left horizontal head impulse paradigm, intraclass correlation coefficient=0.77; right anterior head impulse paradigm, intraclass correlation coefficient=0.86; left anterior head impulse paradigm, intraclass correlation coefficient=0.78; right posterior head impulse paradigm, intraclass correlation coefficient=0.78; left posterior head impulse paradigm, intraclass correlation coefficient=0.75; right horizontal suppression head impulse paradigm, intraclass correlation coefficient=0.76; left horizontal suppression head impulse paradigm, intraclass correlation coefficient=0.79). The test-retest reliability for suppression head impulse paradigmanti-compensatory saccade latency and amplitude were moderate (right latency, intraclass correlation coefficient=0.61; left latency, intraclass correlation coefficient=0.69; right amplitude, intraclass correlation coefficient=0.69; left amplitude, intraclass correlation coefficient=0.58). There were no significant effects of age on head impulse paradigm and suppression head impulse paradigm vestibulo-ocular reflex gain values and suppression head impulse paradigmsaccade latency. However, the saccade amplitude became smaller with increasing age, P < .001. The horizontal suppression head impulse paradigm vestibuloocular reflex gain values were significantly lower than the head impulse paradigm for both sides (right, P = .004; left, P = .004).

Conclusion: There was good test-retest reliability for both measures, and the gain values stabilized with age. However, suppression head impulse paradigm anti-compensatory saccade latency and amplitude had lower test-retest reliability than the gain. The suppression head impulse paradigm vestibulo-ocular reflex gain was lower than the head impulse paradigm and its anti-compensatory saccade amplitude reduced with increasing age.

Abstract Image

Abstract Image

Abstract Image

重测信度、年龄影响及水头冲量与抑制水头冲量的水平2半规管增益值比较。
背景:本研究探讨了头部脉冲范式和抑制头部脉冲范式在水平半规管增益值上的重测信度、老化效应和差异。方法:60名年龄在22 ~ 76岁之间的健康成人(平均±标准差=47.27±18.29)采用视频头冲动测试分为头冲动范式和抑制头冲动范式。头部脉冲模式用于评估所有6个半规管,而抑制头部脉冲模式仅测量水平管。20名年龄22 ~ 40岁(25.25±4.9)的被试进行第二次重测信度测试。结果:两种测量方法的重测信度均较好(右水平头部脉冲范式,类内相关系数=0.80;左水平头脉冲范式,类内相关系数=0.77;右前脑脉冲范式,组内相关系数=0.86;左前脑脉冲范式,类内相关系数=0.78;右后脑冲动范式,组内相关系数=0.78;左后头脉冲范式,类内相关系数=0.75;右水平抑制头脉冲范式,类内相关系数=0.76;左侧水平抑制头脉冲范式,类内相关系数=0.79)。抑制头冲动范式代偿性扫视潜伏期和幅度的重测信度为中等(右潜伏期,类内相关系数=0.61;左潜伏期,类内相关系数=0.69;右振幅,类内相关系数=0.69;左幅,类内相关系数=0.58)。年龄对头冲动范式和抑制头冲动范式前庭-眼反射增益值及抑制头冲动范式跃起潜伏期无显著影响。随着年龄的增长,扫视幅度逐渐减小,P < 0.001。水平抑制头脉冲范式前庭反射增益值显著低于两侧头脉冲范式(右,P = 0.004;左,P = .004)。结论:两种测量方法均具有良好的重测信度,且增益值随年龄增长而稳定。而抑制头脉冲范式抗代偿性扫视潜伏期和振幅的重测信度低于增益。抑制头冲动模式的前庭眼反射增益低于头冲动模式,其抗代偿性扫视振幅随年龄的增加而降低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.80
自引率
0.00%
发文量
94
审稿时长
6-12 weeks
期刊介绍: The Journal of International Advanced Otology (IAO – Citation Abbreviation: J Int Adv Otol) is an open access double-blind peer-reviewed, international publication. The Journal of International Advanced Otology is fully sponsored and owned by the European Academy of Otology and Neurotology and the Politzer Society. The Journal of International Advanced Otology is published 3 times per year on April, August, December and its publication language is English. The scope of the Journal is limited with otology, neurotology, audiology (excluding linguistics) and skull base medicine. The Journal of International Advanced Otology aims to publish manuscripts at the highest clinical and scientific level. IAO publishes original articles in the form of clinical and basic research, review articles, short reports and a limited number of case reports. Controversial patient discussions, communications on emerging technology, and historical issues will also be considered for publication.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书