Factors Influencing the Accuracy of Guided Surgery: An In Vitro Trial.

IF 1.7 4区 医学 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
Norberto Quispe-López, Javier Flores-Fraile, Beatriz Pardal-Peláez, Juan Delgado-Martínez, Javier Montero
{"title":"Factors Influencing the Accuracy of Guided Surgery: An In Vitro Trial.","authors":"Norberto Quispe-López,&nbsp;Javier Flores-Fraile,&nbsp;Beatriz Pardal-Peláez,&nbsp;Juan Delgado-Martínez,&nbsp;Javier Montero","doi":"10.11607/jomi.9794","DOIUrl":null,"url":null,"abstract":"<p><p><b>Purpose:</b> To examine how the accuracy (linear and angular deviation) of implants placed using computer-guided surgery varies in relation to the type of surgical technique (fully guided, half-guided, vs freehand implant placement), bone density (type D1 to D4 bone), and type of support surface (tooth- vs mucosa-supported). <b>Materials and Methods:</b> A total of 32 mandible models were produced (16 partially edentulous and 16 edentulous) using acrylic resin, each calibrated to a different bone density (D1 to D4). Four implants planned using Mguide software were placed in each acrylic resin mandible. A total of 128 implants were placed, distributed according to bone density (D1 to D4, n = 32), the degree of intervention in the surgery (fully guided [FG] = 80, half-guided [HG] = 32, and freehand surgery [F] = 16), and the type of support surface (tooth-supported: n = 64 and mucosa-supported: n = 64). To determine the linear, vertical, and angular deviations between the planned three-dimensional position and the actual position of the implants, the linear and angular difference between them was calculated, with the analysis performed through preoperative and postoperative CBCT scans. The effect was analyzed using parametric tests and linear regression models. <b>Results:</b> All parameters of linear and angular discrepancy in the various regions analyzed (neck, body, and apex) were primarily influenced by the technique and, to a lesser extent, by the bone type, although both variables were predictive and highly significant. These discrepancies tend to increase in completely edentulous models. The regression models show that linear deviations increase by between 630.2 μm at neck level in the buccolingual direction and 836.7 μm at apex level in the mesiodistal direction when comparing the FG and HG techniques. This increase is accumulative when comparing the HG and F techniques. Regarding the effect of bone density, the regression models found that linear discrepancies increase by between 132.6 μm in the axial direction and 199.0 μm at the apex of the implant in the buccolingual direction with each reduction in bone density (D1 to D4). <b>Conclusion:</b> According to this in vitro study, the highest implant placement predictability is found among dentate models with high bone density and a fully guided surgical technique.</p>","PeriodicalId":50298,"journal":{"name":"International Journal of Oral & Maxillofacial Implants","volume":"38 1","pages":"120-129"},"PeriodicalIF":1.7000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Oral & Maxillofacial Implants","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11607/jomi.9794","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To examine how the accuracy (linear and angular deviation) of implants placed using computer-guided surgery varies in relation to the type of surgical technique (fully guided, half-guided, vs freehand implant placement), bone density (type D1 to D4 bone), and type of support surface (tooth- vs mucosa-supported). Materials and Methods: A total of 32 mandible models were produced (16 partially edentulous and 16 edentulous) using acrylic resin, each calibrated to a different bone density (D1 to D4). Four implants planned using Mguide software were placed in each acrylic resin mandible. A total of 128 implants were placed, distributed according to bone density (D1 to D4, n = 32), the degree of intervention in the surgery (fully guided [FG] = 80, half-guided [HG] = 32, and freehand surgery [F] = 16), and the type of support surface (tooth-supported: n = 64 and mucosa-supported: n = 64). To determine the linear, vertical, and angular deviations between the planned three-dimensional position and the actual position of the implants, the linear and angular difference between them was calculated, with the analysis performed through preoperative and postoperative CBCT scans. The effect was analyzed using parametric tests and linear regression models. Results: All parameters of linear and angular discrepancy in the various regions analyzed (neck, body, and apex) were primarily influenced by the technique and, to a lesser extent, by the bone type, although both variables were predictive and highly significant. These discrepancies tend to increase in completely edentulous models. The regression models show that linear deviations increase by between 630.2 μm at neck level in the buccolingual direction and 836.7 μm at apex level in the mesiodistal direction when comparing the FG and HG techniques. This increase is accumulative when comparing the HG and F techniques. Regarding the effect of bone density, the regression models found that linear discrepancies increase by between 132.6 μm in the axial direction and 199.0 μm at the apex of the implant in the buccolingual direction with each reduction in bone density (D1 to D4). Conclusion: According to this in vitro study, the highest implant placement predictability is found among dentate models with high bone density and a fully guided surgical technique.

影响引导手术准确性的因素:一项体外试验。
目的:研究使用计算机引导手术放置种植体的准确性(线性和角偏差)与手术技术类型(全引导,半引导,与徒手种植体放置),骨密度(D1型至D4型骨)和支持面类型(牙齿支持vs粘膜支持)有关。材料和方法:使用丙烯酸树脂制作32个下颌骨模型(16个部分无牙和16个无牙),每个模型都校准到不同的骨密度(D1至D4)。使用Mguide软件计划在每个丙烯酸树脂下颌骨放置四个种植体。共放置种植体128枚,根据骨密度(D1 ~ D4, n = 32)、手术干预程度(全引导[FG] = 80,半引导[HG] = 32,徒手手术[F] = 16)、支撑面类型(牙支撑:n = 64,粘膜支撑:n = 64)进行分布。为了确定种植体的规划三维位置与实际位置之间的直线、垂直和角度偏差,通过术前和术后CBCT扫描计算它们之间的直线和角度差。采用参数检验和线性回归模型对效果进行分析。结果:所分析的各个区域(颈部、身体和尖端)的线性和角度差异的所有参数主要受技术的影响,在较小程度上受骨类型的影响,尽管这两个变量都具有预测性和高度显著性。在完全无牙的模型中,这些差异往往会增加。回归模型表明,在中远端方向上,FG技术与HG技术的线性偏差在颈部水平增加了630.2 μm,在尖部水平增加了836.7 μm。在比较HG和F技术时,这种增加是累积的。对于骨密度的影响,回归模型发现,骨密度每降低一次,种植体顶端轴向的线性差异增加132.6 μm,颊舌方向的线性差异增加199.0 μm (D1 ~ D4)。结论:根据这项体外研究,高骨密度和完全引导手术技术的齿状模型中种植体放置的可预测性最高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.30
自引率
5.00%
发文量
115
审稿时长
6 months
期刊介绍: Edited by Steven E. Eckert, DDS, MS ISSN (Print): 0882-2786 ISSN (Online): 1942-4434 This highly regarded, often-cited journal integrates clinical and scientific data to improve methods and results of oral and maxillofacial implant therapy. It presents pioneering research, technology, clinical applications, reviews of the literature, seminal studies, emerging technology, position papers, and consensus studies, as well as the many clinical and therapeutic innovations that ensue as a result of these efforts. The editorial board is composed of recognized opinion leaders in their respective areas of expertise and reflects the international reach of the journal. Under their leadership, JOMI maintains its strong scientific integrity while expanding its influence within the field of implant dentistry. JOMI’s popular regular feature "Thematic Abstract Review" presents a review of abstracts of recently published articles on a specific topical area of interest each issue.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信