Matrix Metalloproteinase-8 Levels in Peri-Miniscrew Crevicular Fluid During Immediate and Delayed Orthodontic Loading--A Split-Mouth Study.

IF 1.7 4区 医学 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
Dhanashree D Khot, Veera I Bhosale, Seyedeh Sara Kamyab, Alpana Subodh Moghe, Amol Somaji Patil
{"title":"Matrix Metalloproteinase-8 Levels in Peri-Miniscrew Crevicular Fluid During Immediate and Delayed Orthodontic Loading--A Split-Mouth Study.","authors":"Dhanashree D Khot,&nbsp;Veera I Bhosale,&nbsp;Seyedeh Sara Kamyab,&nbsp;Alpana Subodh Moghe,&nbsp;Amol Somaji Patil","doi":"10.11607/jomi.9705","DOIUrl":null,"url":null,"abstract":"<p><p><b>Purpose:</b> To compare the matrix metalloproteinase-8 (MMP-8) levels in the peri-miniscrew implant crevicular fluid (PMCF) of immediate-loaded and delayed-loaded miniscrew implants at different time intervals. <b>Materials and Methods:</b> Titanium orthodontic miniscrews were placed bilaterally in the attached gingiva of 15 patients between the maxillary second premolar and maxillary first molar for en masse retraction. This split-mouth study was designed to have an immediate-loaded miniscrew on one side and a delayed-loaded miniscrew on the other side that was loaded 8 days after miniscrew placement. PMCF was collected from the mesiobuccal aspects of the immediate-loaded implants at 24 hours, 8 days, and 28 days after loading, and from the delayed-loaded miniscrew implants at 24 hours and 8 days before loading and 24 hours and 28 days after loading. An enzyme-linked immunosorbent assay kit was used to assess MMP-8 levels in the PMCF samples. Unpaired <i>t</i> test, ANOVA F-test, and Tukey post hoc test were used to evaluate data at the <i>P</i> < .05 level. <b>Results:</b> Although there were slight alterations in the MMP-8 levels in the PMCF over time, there was no statistically significant difference in the MMP-8 levels between groups. There was a statistically significant decrease in the levels of MMP-8 between 24 hours after miniscrew placement and 28 days after loading on the delayed-loaded side (<i>P</i> < .05). <b>Conclusion:</b> The MMP-8 levels did not vary much between immediate-loaded and delayed-loaded miniscrew implants as a result of the force application. However, there was no significant difference between immediate loading and delayed loading in terms of biologic response to mechanical stress. The increase in MMP-8 levels after 24 hours post-miniscrew insertion, as well as the subsequent gradual reduction over the course of the study period in both immediate and delayed groups after loading, is probably due to the bone adapting to stimuli.</p>","PeriodicalId":50298,"journal":{"name":"International Journal of Oral & Maxillofacial Implants","volume":"38 1","pages":"130-135"},"PeriodicalIF":1.7000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Oral & Maxillofacial Implants","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11607/jomi.9705","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To compare the matrix metalloproteinase-8 (MMP-8) levels in the peri-miniscrew implant crevicular fluid (PMCF) of immediate-loaded and delayed-loaded miniscrew implants at different time intervals. Materials and Methods: Titanium orthodontic miniscrews were placed bilaterally in the attached gingiva of 15 patients between the maxillary second premolar and maxillary first molar for en masse retraction. This split-mouth study was designed to have an immediate-loaded miniscrew on one side and a delayed-loaded miniscrew on the other side that was loaded 8 days after miniscrew placement. PMCF was collected from the mesiobuccal aspects of the immediate-loaded implants at 24 hours, 8 days, and 28 days after loading, and from the delayed-loaded miniscrew implants at 24 hours and 8 days before loading and 24 hours and 28 days after loading. An enzyme-linked immunosorbent assay kit was used to assess MMP-8 levels in the PMCF samples. Unpaired t test, ANOVA F-test, and Tukey post hoc test were used to evaluate data at the P < .05 level. Results: Although there were slight alterations in the MMP-8 levels in the PMCF over time, there was no statistically significant difference in the MMP-8 levels between groups. There was a statistically significant decrease in the levels of MMP-8 between 24 hours after miniscrew placement and 28 days after loading on the delayed-loaded side (P < .05). Conclusion: The MMP-8 levels did not vary much between immediate-loaded and delayed-loaded miniscrew implants as a result of the force application. However, there was no significant difference between immediate loading and delayed loading in terms of biologic response to mechanical stress. The increase in MMP-8 levels after 24 hours post-miniscrew insertion, as well as the subsequent gradual reduction over the course of the study period in both immediate and delayed groups after loading, is probably due to the bone adapting to stimuli.

即刻和延迟正畸负荷时微牙槽液中基质金属蛋白酶-8的水平——一项裂口研究。
目的:比较即刻加载和延迟加载微型种植体不同时间间隔的微种植体周围沟液(PMCF)中基质金属蛋白酶-8 (MMP-8)水平。材料与方法:在15例患者的上颌第二前磨牙与上颌第一磨牙之间的附着龈两侧放置钛质正畸微钉进行整体内收。这项裂口研究的设计是在一侧有一个立即加载的微型螺钉,在另一侧有一个延迟加载的微型螺钉,在微型螺钉放置8天后加载。在加载后24小时、8天、28天采集即刻加载种植体的中颊部PMCF,在加载前24小时、8天、加载后24小时、28天采集延迟加载微型种植体的中颊部PMCF。酶联免疫吸附测定试剂盒用于评估PMCF样品中的MMP-8水平。采用未配对t检验、方差分析f检验和Tukey事后检验对数据进行评价,P < 0.05水平。结果:虽然随着时间的推移,PMCF中MMP-8水平有轻微变化,但组间MMP-8水平无统计学差异。MMP-8水平在放置微钉后24小时和延迟加载侧加载后28天之间有统计学意义(P < 0.05)。结论:MMP-8水平在即刻加载和延迟加载的微型种植体之间没有太大的差异。然而,就机械应力的生物反应而言,即时加载和延迟加载之间没有显着差异。在加载后立即组和延迟组中,MMP-8水平在置入24小时后升高,以及随后在整个研究期间逐渐降低,可能是由于骨适应刺激。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.30
自引率
5.00%
发文量
115
审稿时长
6 months
期刊介绍: Edited by Steven E. Eckert, DDS, MS ISSN (Print): 0882-2786 ISSN (Online): 1942-4434 This highly regarded, often-cited journal integrates clinical and scientific data to improve methods and results of oral and maxillofacial implant therapy. It presents pioneering research, technology, clinical applications, reviews of the literature, seminal studies, emerging technology, position papers, and consensus studies, as well as the many clinical and therapeutic innovations that ensue as a result of these efforts. The editorial board is composed of recognized opinion leaders in their respective areas of expertise and reflects the international reach of the journal. Under their leadership, JOMI maintains its strong scientific integrity while expanding its influence within the field of implant dentistry. JOMI’s popular regular feature "Thematic Abstract Review" presents a review of abstracts of recently published articles on a specific topical area of interest each issue.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信