Influence of Splint Support on the Precision of Static Totally Guided Dental Implant Surgery: A Systematic Review and Network Meta-analysis.

IF 1.7 4区 医学 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
José Carlos Balaguer-Martí, Álvaro Canet-López, Miguel Peñarrocha-Diago, Marta Romeo-Rubio, María Peñarrocha-Diago, Berta García-Mira
{"title":"Influence of Splint Support on the Precision of Static Totally Guided Dental Implant Surgery: A Systematic Review and Network Meta-analysis.","authors":"José Carlos Balaguer-Martí,&nbsp;Álvaro Canet-López,&nbsp;Miguel Peñarrocha-Diago,&nbsp;Marta Romeo-Rubio,&nbsp;María Peñarrocha-Diago,&nbsp;Berta García-Mira","doi":"10.11607/jomi.9796","DOIUrl":null,"url":null,"abstract":"<p><p><b>Purpose:</b> To assess the accuracy of totally guided implant placement with static surgical splints in relation to the different types of supporting tissues (tooth, mucosa, or bone). <b>Materials and Methods:</b> This review was carried out following the PRISMA guidelines. An electronic search was done of the MEDLINE (PubMed), Embase, and Cochrane Library databases, without publication year or language restrictions. <b>Results:</b> The literature search yielded a total of 877 articles; 18 were included in the qualitative synthesis, and 16 of these articles were included in the quantitative analysis. The included studies presented a high risk of bias, except for one randomized clinical trial. The strength of the recommendations is therefore weak. In the angular deviation treatment, statistically significant differences were observed in the accuracy of the implants with tooth vs bone support: Bone support yielded 1.31 degrees greater deviation vs tooth support (SD = 0.43; 95% CI: 0.47, 2.15, <i>P</i> = .002). No significant differences were observed in the linear deviations. <b>Conclusion:</b> Tooth support proved to be significantly more precise than bone support splints. There were no differences referring to horizontal coronal deviation, horizontal apical deviation, or vertical deviation according to the type of splint support used.</p>","PeriodicalId":50298,"journal":{"name":"International Journal of Oral & Maxillofacial Implants","volume":"38 1","pages":"157-168"},"PeriodicalIF":1.7000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Oral & Maxillofacial Implants","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11607/jomi.9796","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To assess the accuracy of totally guided implant placement with static surgical splints in relation to the different types of supporting tissues (tooth, mucosa, or bone). Materials and Methods: This review was carried out following the PRISMA guidelines. An electronic search was done of the MEDLINE (PubMed), Embase, and Cochrane Library databases, without publication year or language restrictions. Results: The literature search yielded a total of 877 articles; 18 were included in the qualitative synthesis, and 16 of these articles were included in the quantitative analysis. The included studies presented a high risk of bias, except for one randomized clinical trial. The strength of the recommendations is therefore weak. In the angular deviation treatment, statistically significant differences were observed in the accuracy of the implants with tooth vs bone support: Bone support yielded 1.31 degrees greater deviation vs tooth support (SD = 0.43; 95% CI: 0.47, 2.15, P = .002). No significant differences were observed in the linear deviations. Conclusion: Tooth support proved to be significantly more precise than bone support splints. There were no differences referring to horizontal coronal deviation, horizontal apical deviation, or vertical deviation according to the type of splint support used.

夹板支持对静态全引导种植牙手术精度的影响:系统综述和网络荟萃分析。
目的:评估与不同类型的支持组织(牙齿、粘膜或骨骼)相关的完全引导种植体植入静态外科夹板的准确性。材料和方法:本综述按照PRISMA指南进行。对MEDLINE (PubMed)、Embase和Cochrane图书馆数据库进行电子检索,没有出版年份或语言限制。结果:共检索到877篇文献;其中18篇纳入定性综合,16篇纳入定量分析。除一项随机临床试验外,纳入的研究均存在较高的偏倚风险。因此,这些建议的力度很弱。在角度偏差处理中,牙支持种植体与骨支持种植体的精度差异有统计学意义:骨支持种植体比牙支持种植体的偏差大1.31度(SD = 0.43;95% ci: 0.47, 2.15, p = 0.002)。线性偏差无显著差异。结论:牙支撑比骨支撑更精确。根据使用的夹板支持类型,水平冠状偏差、水平根尖偏差或垂直偏差无差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.30
自引率
5.00%
发文量
115
审稿时长
6 months
期刊介绍: Edited by Steven E. Eckert, DDS, MS ISSN (Print): 0882-2786 ISSN (Online): 1942-4434 This highly regarded, often-cited journal integrates clinical and scientific data to improve methods and results of oral and maxillofacial implant therapy. It presents pioneering research, technology, clinical applications, reviews of the literature, seminal studies, emerging technology, position papers, and consensus studies, as well as the many clinical and therapeutic innovations that ensue as a result of these efforts. The editorial board is composed of recognized opinion leaders in their respective areas of expertise and reflects the international reach of the journal. Under their leadership, JOMI maintains its strong scientific integrity while expanding its influence within the field of implant dentistry. JOMI’s popular regular feature "Thematic Abstract Review" presents a review of abstracts of recently published articles on a specific topical area of interest each issue.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信