Next Generation Sequencing for miRNA Detection on the Exhaled Breath Condensate: A Pilot Study.

IF 3.2 Q2 GENETICS & HEREDITY
Roberto Cherchi, Roberto Cusano, Sandro Orrù, Paolo A Ferrari, Matteo Massidda, Giorgio Fotia, Sara De Matteis, Pierluigi Cocco
{"title":"Next Generation Sequencing for miRNA Detection on the Exhaled Breath Condensate: A Pilot Study.","authors":"Roberto Cherchi,&nbsp;Roberto Cusano,&nbsp;Sandro Orrù,&nbsp;Paolo A Ferrari,&nbsp;Matteo Massidda,&nbsp;Giorgio Fotia,&nbsp;Sara De Matteis,&nbsp;Pierluigi Cocco","doi":"10.1177/25168657231160985","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Exhaled breath condensate (EBC) sampling has been suggested as a less-invasive and cost-effective method to detect biological macromolecules, including miRNA. To explore the feasibility of its use as a biomarker of early effects of asbestos exposure, we conducted a preliminary test on male volunteers by comparing the miRNA profile in the EBC and the plasma using 2 different sequencing platforms.</p><p><strong>Methods: </strong>Six male volunteers, all retired and unexposed to dust or fumes, participated in the test. RNA was extracted from 200 μL EBC samples and same-size plasma samples. Sample aliquots were processed in 2 laboratories using 2 different sequencing platforms: a MiSeq Illumina<sup>®</sup> platform and a more performing HiSeq Illumina<sup>®</sup> platform.</p><p><strong>Results: </strong>The HiSeq3000<sup>®</sup> sequencing platform identified twice as many unique molecular indexes (UMI)-validated miRNA as the MiSeq<sup>®</sup> platform. The Spearman's correlation coefficient between EBC counts and plasma counts was significant in 5/6 subjects with either platform (MiSeq<sup>®</sup> = 0.128-0.508, <i>P</i> = .026-<.001; HiSeq<sup>®</sup> = 0.156-0.412, <i>P</i> = .001-<.001). The intraclass correlation coefficient confirmed the consistency of the miRNA profile over the 6 participants with both biospecimens. Exploring the agreement between the EBC and plasma samples with Bland-Altman plots showed that using the HiSeq3000<sup>®</sup> platform substantially improved the EBC miRNA detection rate.</p><p><strong>Conclusion: </strong>Our preliminary study confirms that, when using the HiSeq<sup>®</sup> sequencing platform, EBC sampling is a suitable, non-invasive method to detect the miRNA profile in healthy subjects.</p>","PeriodicalId":41996,"journal":{"name":"Epigenetics Insights","volume":null,"pages":null},"PeriodicalIF":3.2000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/9d/23/10.1177_25168657231160985.PMC10070752.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Epigenetics Insights","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/25168657231160985","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"GENETICS & HEREDITY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Exhaled breath condensate (EBC) sampling has been suggested as a less-invasive and cost-effective method to detect biological macromolecules, including miRNA. To explore the feasibility of its use as a biomarker of early effects of asbestos exposure, we conducted a preliminary test on male volunteers by comparing the miRNA profile in the EBC and the plasma using 2 different sequencing platforms.

Methods: Six male volunteers, all retired and unexposed to dust or fumes, participated in the test. RNA was extracted from 200 μL EBC samples and same-size plasma samples. Sample aliquots were processed in 2 laboratories using 2 different sequencing platforms: a MiSeq Illumina® platform and a more performing HiSeq Illumina® platform.

Results: The HiSeq3000® sequencing platform identified twice as many unique molecular indexes (UMI)-validated miRNA as the MiSeq® platform. The Spearman's correlation coefficient between EBC counts and plasma counts was significant in 5/6 subjects with either platform (MiSeq® = 0.128-0.508, P = .026-<.001; HiSeq® = 0.156-0.412, P = .001-<.001). The intraclass correlation coefficient confirmed the consistency of the miRNA profile over the 6 participants with both biospecimens. Exploring the agreement between the EBC and plasma samples with Bland-Altman plots showed that using the HiSeq3000® platform substantially improved the EBC miRNA detection rate.

Conclusion: Our preliminary study confirms that, when using the HiSeq® sequencing platform, EBC sampling is a suitable, non-invasive method to detect the miRNA profile in healthy subjects.

Abstract Image

Abstract Image

Abstract Image

呼气凝析液中miRNA检测的新一代测序:一项初步研究。
呼气冷凝物(EBC)取样已被认为是一种侵入性低、成本效益高的生物大分子检测方法,包括miRNA。为了探索其作为石棉暴露早期影响的生物标志物的可行性,我们对男性志愿者进行了初步测试,使用两种不同的测序平台比较了EBC和血浆中的miRNA谱。方法:六名男性志愿者参加了测试,他们都是退休的,没有接触过灰尘或烟雾。从200 μL的EBC样本和相同大小的血浆样本中提取RNA。样品等分在2个实验室使用2种不同的测序平台进行处理:MiSeq Illumina®平台和性能更高的HiSeq Illumina®平台。结果:HiSeq3000®测序平台鉴定出的独特分子指数(UMI)验证的miRNA数量是MiSeq®平台的两倍。在两种平台中,5/6名受试者的EBC计数与血浆计数的Spearman相关系数均显著(MiSeq®= 0.128-0.508,P = 0.026 -®= 0.156-0.412,P =。001-®平台显著提高了EBC miRNA的检出率。结论:我们的初步研究证实,当使用HiSeq®测序平台时,EBC取样是一种适合的、无创的方法来检测健康受试者的miRNA谱。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Epigenetics Insights
Epigenetics Insights GENETICS & HEREDITY-
CiteScore
5.10
自引率
0.00%
发文量
10
审稿时长
8 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信