Dual-Peak Lorentzian CEST MRI for antiretroviral drug brain distribution.

NeuroImmune pharmacology and therapeutics Pub Date : 2023-03-25 Epub Date: 2022-09-13 DOI:10.1515/nipt-2022-0012
Yutong Liu, Gabriel C Gauthier, Howard E Gendelman, Aditya N Bade
{"title":"Dual-Peak Lorentzian CEST MRI for antiretroviral drug brain distribution.","authors":"Yutong Liu, Gabriel C Gauthier, Howard E Gendelman, Aditya N Bade","doi":"10.1515/nipt-2022-0012","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Spatial-temporal biodistribution of antiretroviral drugs (ARVs) can now be achieved using MRI by utilizing chemical exchange saturation transfer (CEST) contrasts. However, the presence of biomolecules in tissue limits the specificity of current CEST methods. To overcome this limitation, a Lorentzian line-shape fitting algorithm was developed that simultaneously fits CEST peaks of ARV protons on its Z-spectrum.</p><p><strong>Case presentation: </strong>This algorithm was tested on the common first line ARV, lamivudine (3TC), that has two peaks resulting from amino (-NH<sub>2</sub>) and hydroxyl (-OH) protons in 3TC. The developed dual-peak Lorentzian function fitted these two peaks simultaneously, and used the ratio of -NH<sub>2</sub> and -OH CEST contrasts as a constraint parameter to measure 3TC presence in brains of drug-treated mice. 3TC biodistribution calculated using the new algorithm was compared against actual drug levels measured using UPLC-MS/MS. In comparison to the method that employs the -NH<sub>2</sub> CEST peak only, the dual-peak Lorentzian fitting algorithm showed stronger correlation with brain tissue 3TC levels, signifying estimation of actual drug levels.</p><p><strong>Conclusions: </strong>We concluded that 3TC levels can be extracted from confounding CEST effects of tissue biomolecules resulting in improved specificity for drug mapping. This algorithm can be expanded to measure a variety of ARVs using CEST MRI.</p>","PeriodicalId":74278,"journal":{"name":"NeuroImmune pharmacology and therapeutics","volume":"2 1","pages":"63-69"},"PeriodicalIF":0.0000,"publicationDate":"2023-03-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10070014/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"NeuroImmune pharmacology and therapeutics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1515/nipt-2022-0012","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/9/13 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: Spatial-temporal biodistribution of antiretroviral drugs (ARVs) can now be achieved using MRI by utilizing chemical exchange saturation transfer (CEST) contrasts. However, the presence of biomolecules in tissue limits the specificity of current CEST methods. To overcome this limitation, a Lorentzian line-shape fitting algorithm was developed that simultaneously fits CEST peaks of ARV protons on its Z-spectrum.

Case presentation: This algorithm was tested on the common first line ARV, lamivudine (3TC), that has two peaks resulting from amino (-NH2) and hydroxyl (-OH) protons in 3TC. The developed dual-peak Lorentzian function fitted these two peaks simultaneously, and used the ratio of -NH2 and -OH CEST contrasts as a constraint parameter to measure 3TC presence in brains of drug-treated mice. 3TC biodistribution calculated using the new algorithm was compared against actual drug levels measured using UPLC-MS/MS. In comparison to the method that employs the -NH2 CEST peak only, the dual-peak Lorentzian fitting algorithm showed stronger correlation with brain tissue 3TC levels, signifying estimation of actual drug levels.

Conclusions: We concluded that 3TC levels can be extracted from confounding CEST effects of tissue biomolecules resulting in improved specificity for drug mapping. This algorithm can be expanded to measure a variety of ARVs using CEST MRI.

Abstract Image

Abstract Image

Abstract Image

抗逆转录病毒药物脑分布的双峰洛伦兹CEST磁共振成像。
目的:利用化学交换饱和转移(CEST)对比,现在可以通过磁共振成像实现抗逆转录病毒药物(ARV)的时空生物分布。然而,组织中生物分子的存在限制了目前 CEST 方法的特异性。为了克服这一限制,我们开发了一种洛伦兹线形拟合算法,可同时拟合 ARV 质子在其 Z 光谱上的 CEST 峰:该算法在常见的一线抗逆转录病毒药物拉米夫定(3TC)上进行了测试,3TC 中的氨基(-NH2)质子和羟基(-OH)质子产生了两个峰。所开发的双峰洛伦兹函数同时拟合了这两个峰,并将 -NH2 和 -OH CEST 对比度的比值作为限制参数来测量药物治疗小鼠大脑中 3TC 的存在。使用新算法计算出的 3TC 生物分布与使用 UPLC-MS/MS 测得的实际药物水平进行了比较。与仅采用-NH2 CEST峰的方法相比,双峰洛伦兹拟合算法与脑组织中的3TC水平显示出更强的相关性,表明对实际药物水平进行了估计:我们的结论是,3TC 水平可以从组织生物大分子的混杂 CEST 效应中提取出来,从而提高药物绘图的特异性。这种算法可以扩展到使用 CEST MRI 测量各种抗逆转录病毒药物。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信