Rapid quantification of phenobarbital and barbital in human whole blood by liquid-liquid extraction combined with DART-orbitrap-HRMS.

IF 2.8 4区 医学 Q2 TOXICOLOGY
Shi Ke, Ru Lian, Rong Wang, Yulan Rao, Chen Liang, Jianying Liang, Yurong Zhang
{"title":"Rapid quantification of phenobarbital and barbital in human whole blood by liquid-liquid extraction combined with DART-orbitrap-HRMS.","authors":"Shi Ke,&nbsp;Ru Lian,&nbsp;Rong Wang,&nbsp;Yulan Rao,&nbsp;Chen Liang,&nbsp;Jianying Liang,&nbsp;Yurong Zhang","doi":"10.1007/s11419-022-00650-w","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aims to develop and validate a rapid, simple, and efficient bioanalytical method for the simultaneous quantification of phenobarbital and barbital in human whole blood using liquid-liquid extraction combined with direct analysis in real time (DART) and high-resolution mass spectrometry (HRMS).</p><p><strong>Method: </strong>Phenobarbital-d5 and aprobarbital were selected as internal standards (ISs) of phenobarbital and barbital, respectively. A mixed solvent of o-xylene and ethyl acetate at a ratio of 1:6 was used to extract analytes of interest and ISs from 100 μL of human whole blood samples. Phenobarbital and barbital were detected by DART-HRMS. The proposed method has been validated in accordance with United States Food and Drug Administration Guidelines for Bioanalytical Method Validation in terms of selectivity, linearity, accuracy, precision, matrix effect, recovery, stability, and dilution integrity.</p><p><strong>Results: </strong>The lower limits of quantification (LLOQs) of phenobarbital and barbital were both 10 ng/mL. The linearities were in the range of 10-1000 ng/mL (R<sup>2</sup> ≥ 0.99). The mean recovery values of phenobarbital and barbital were 99.7% and 88.1%, respectively. The interday and intraday precision values were less than 10.4%, and the interday and intraday accuracy values ranged from 87.6 to 106.7%. Furthermore, the validated method was applied to four cases of phenobarbital poisoning at the Shanghai Institute of Forensic Science.</p><p><strong>Conclusion: </strong>The developed and fully validated method enabled the simultaneous quantification of phenobarbital and barbital in human whole blood and was successfully applied to authentic cases.</p>","PeriodicalId":12329,"journal":{"name":"Forensic Toxicology","volume":null,"pages":null},"PeriodicalIF":2.8000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Forensic Toxicology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11419-022-00650-w","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"TOXICOLOGY","Score":null,"Total":0}
引用次数: 1

Abstract

Purpose: This study aims to develop and validate a rapid, simple, and efficient bioanalytical method for the simultaneous quantification of phenobarbital and barbital in human whole blood using liquid-liquid extraction combined with direct analysis in real time (DART) and high-resolution mass spectrometry (HRMS).

Method: Phenobarbital-d5 and aprobarbital were selected as internal standards (ISs) of phenobarbital and barbital, respectively. A mixed solvent of o-xylene and ethyl acetate at a ratio of 1:6 was used to extract analytes of interest and ISs from 100 μL of human whole blood samples. Phenobarbital and barbital were detected by DART-HRMS. The proposed method has been validated in accordance with United States Food and Drug Administration Guidelines for Bioanalytical Method Validation in terms of selectivity, linearity, accuracy, precision, matrix effect, recovery, stability, and dilution integrity.

Results: The lower limits of quantification (LLOQs) of phenobarbital and barbital were both 10 ng/mL. The linearities were in the range of 10-1000 ng/mL (R2 ≥ 0.99). The mean recovery values of phenobarbital and barbital were 99.7% and 88.1%, respectively. The interday and intraday precision values were less than 10.4%, and the interday and intraday accuracy values ranged from 87.6 to 106.7%. Furthermore, the validated method was applied to four cases of phenobarbital poisoning at the Shanghai Institute of Forensic Science.

Conclusion: The developed and fully validated method enabled the simultaneous quantification of phenobarbital and barbital in human whole blood and was successfully applied to authentic cases.

Abstract Image

液液萃取联合DART-orbitrap-HRMS快速定量人全血中苯巴比妥和巴比妥的含量。
目的:建立并验证一种快速、简便、高效的液液萃取结合实时直接分析(DART)和高分辨率质谱(HRMS)同时定量人全血中苯巴比妥和巴比妥的生物分析方法。方法:选择苯巴比妥d5和阿巴比妥分别作为苯巴比妥和巴比妥的内标(ISs)。采用邻二甲苯和乙酸乙酯的混合溶剂,以1:6的比例从100 μL的人全血样品中提取目的分析物和ISs。采用DART-HRMS检测苯巴比妥和巴比妥。根据美国食品和药物管理局生物分析方法验证指南,在选择性、线性、准确度、精密度、基质效应、回收率、稳定性和稀释完整性方面对该方法进行了验证。结果:苯巴比妥和巴比妥的定量下限均为10 ng/mL。线性关系在10 ~ 1000 ng/mL范围内(R2≥0.99)。苯巴比妥和巴比妥的平均回收率分别为99.7%和88.1%。日间和日内精度值均小于10.4%,日间和日内精度值在87.6 ~ 106.7%之间。并将该方法应用于上海法医学研究所的4例苯巴比妥中毒病例。结论:建立的方法能够同时测定人全血中苯巴比妥和巴比妥的含量,并能成功应用于真实病例。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Forensic Toxicology
Forensic Toxicology TOXICOLOGY-
CiteScore
5.80
自引率
9.10%
发文量
40
审稿时长
3 months
期刊介绍: The journal Forensic Toxicology provides an international forum for publication of studies on toxic substances, drugs of abuse, doping agents, chemical warfare agents, and their metabolisms and analyses, which are related to laws and ethics. It includes original articles, reviews, mini-reviews, short communications, and case reports. Although a major focus of the journal is on the development or improvement of analytical methods for the above-mentioned chemicals in human matrices, appropriate studies with animal experiments are also published. Forensic Toxicology is the official publication of the Japanese Association of Forensic Toxicology (JAFT) and is the continuation of the Japanese Journal of Forensic Toxicology (ISSN 0915-9606).
文献相关原料
公司名称 产品信息 采购帮参考价格
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信