Marcos Moreno-Verdú, María Del Rosario Ferreira-Sánchez, Patricia Martín-Casas, María de Los Ángeles Atín-Arratibel
{"title":"Test-Retest Reliability and Criterion Validity of the Spanish Version of Two Motor Imagery Questionnaires in People With Parkinson Disease.","authors":"Marcos Moreno-Verdú, María Del Rosario Ferreira-Sánchez, Patricia Martín-Casas, María de Los Ángeles Atín-Arratibel","doi":"10.1097/NPT.0000000000000416","DOIUrl":null,"url":null,"abstract":"Background and purpose: The Kinesthetic and Visual Imagery Questionnaire (KVIQ) and the Movement Imagery Questionnaire-Revised Second Version (MIQ-RS) are measurement instruments that assess motor imagery vividness. The aim of this study was to examine the validity and reliability of the Spanish KVIQ and MIQ-RS in people with Parkinson disease (PD). Methods: A longitudinal descriptive study was conducted following the COSMIN standards. Thirty-five people with idiopathic PD were evaluated twice (7-15 days apart) with the Spanish KVIQ and MIQ-RS. Structural validity, internal consistency, test-retest reliability (ICC), standard error of measurement (SEM), smallest detectable change (SDC), and criterion validity of the MIQ-RS and KVIQ long (KVIQ-20), short (KVIQ-10), and extended (KVIQ-34) versions and their subscales (if pertinent) were tested. Results: Factor analysis was satisfactory for the MIQ-RS, KVIQ-20, and KVIQ-10, providing evidence of their 2-dimensional structure. Evidence of the structural validity of the KVIQ-34 was not confirmed and thus was analyzed as an overall score. Revelle's ω > 0.9 showed excellent internal consistency. Test-retest reliability was moderate (ICC = 0.58-0.75) and higher for all visual subscales. SEM and SDC were up to 14.39% and 39.89% of the scores, respectively. Criterion validity between questionnaires and subscales was strong (Spearman's r > 0.7). Discussion and Conclusions: The results provide evidence for the validity and reliability of the Spanish MIQ-RS, KVIQ-20, and KVIQ-10 to assess motor imagery vividness in people with PD, whereas the KVIQ-34 should only be interpreted as an overall score. Psychometric, procedural, and practical features of the questionnaires should be considered when applying into clinical practice. Video Abstract available for more insights from the authors (see the Video, Supplemental Digital Content 1, available at: http://links.lww.com/JNPT/A401).","PeriodicalId":49030,"journal":{"name":"Journal of Neurologic Physical Therapy","volume":"47 1","pages":"35-43"},"PeriodicalIF":2.6000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Neurologic Physical Therapy","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/NPT.0000000000000416","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 1
Abstract
Background and purpose: The Kinesthetic and Visual Imagery Questionnaire (KVIQ) and the Movement Imagery Questionnaire-Revised Second Version (MIQ-RS) are measurement instruments that assess motor imagery vividness. The aim of this study was to examine the validity and reliability of the Spanish KVIQ and MIQ-RS in people with Parkinson disease (PD). Methods: A longitudinal descriptive study was conducted following the COSMIN standards. Thirty-five people with idiopathic PD were evaluated twice (7-15 days apart) with the Spanish KVIQ and MIQ-RS. Structural validity, internal consistency, test-retest reliability (ICC), standard error of measurement (SEM), smallest detectable change (SDC), and criterion validity of the MIQ-RS and KVIQ long (KVIQ-20), short (KVIQ-10), and extended (KVIQ-34) versions and their subscales (if pertinent) were tested. Results: Factor analysis was satisfactory for the MIQ-RS, KVIQ-20, and KVIQ-10, providing evidence of their 2-dimensional structure. Evidence of the structural validity of the KVIQ-34 was not confirmed and thus was analyzed as an overall score. Revelle's ω > 0.9 showed excellent internal consistency. Test-retest reliability was moderate (ICC = 0.58-0.75) and higher for all visual subscales. SEM and SDC were up to 14.39% and 39.89% of the scores, respectively. Criterion validity between questionnaires and subscales was strong (Spearman's r > 0.7). Discussion and Conclusions: The results provide evidence for the validity and reliability of the Spanish MIQ-RS, KVIQ-20, and KVIQ-10 to assess motor imagery vividness in people with PD, whereas the KVIQ-34 should only be interpreted as an overall score. Psychometric, procedural, and practical features of the questionnaires should be considered when applying into clinical practice. Video Abstract available for more insights from the authors (see the Video, Supplemental Digital Content 1, available at: http://links.lww.com/JNPT/A401).
期刊介绍:
The Journal of Neurologic Physical Therapy (JNPT) is an indexed resource for dissemination of research-based evidence related to neurologic physical therapy intervention. High standards of quality are maintained through a rigorous, double-blinded, peer-review process and adherence to standards recommended by the International Committee of Medical Journal Editors. With an international editorial board made up of preeminent researchers and clinicians, JNPT publishes articles of global relevance for examination, evaluation, prognosis, intervention, and outcomes for individuals with movement deficits due to neurologic conditions. Through systematic reviews, research articles, case studies, and clinical perspectives, JNPT promotes the integration of evidence into theory, education, research, and practice of neurologic physical therapy, spanning the continuum from pathophysiology to societal participation.