Thermodynamic design data for absorption heat pump systems operating on water-carrol. Part III: Simultaneous cooling and heating

R. Best, W. Rivera, A. Oskam
{"title":"Thermodynamic design data for absorption heat pump systems operating on water-carrol. Part III: Simultaneous cooling and heating","authors":"R. Best,&nbsp;W. Rivera,&nbsp;A. Oskam","doi":"10.1016/0890-4332(95)90053-5","DOIUrl":null,"url":null,"abstract":"<div><p>The Gibbs phase rule and thermodynamic properties of the working pair limit the choice of operating temperatures. For any combination of temperatures, the concentrations in the absorber and the generator and hence the flow ratios are fixed. For any particular working pair, the coefficient of performance is related to the flow ratio.</p><p>Tables of possible combinations of operating temperatures and concentrations, including flow ratics, Carnot coefficients of performance and enthalpy based coefficients of performance have been presented for water-carrol (lithium bromide-ethylene glycol, ratio 4.5) absorption systems for simultaneous cooling and heating. The interactions of operating temperatures have been illustrated graphically.</p></div>","PeriodicalId":100603,"journal":{"name":"Heat Recovery Systems and CHP","volume":"15 5","pages":"Pages 445-456"},"PeriodicalIF":0.0000,"publicationDate":"1995-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0890-4332(95)90053-5","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Heat Recovery Systems and CHP","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/0890433295900535","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The Gibbs phase rule and thermodynamic properties of the working pair limit the choice of operating temperatures. For any combination of temperatures, the concentrations in the absorber and the generator and hence the flow ratios are fixed. For any particular working pair, the coefficient of performance is related to the flow ratio.

Tables of possible combinations of operating temperatures and concentrations, including flow ratics, Carnot coefficients of performance and enthalpy based coefficients of performance have been presented for water-carrol (lithium bromide-ethylene glycol, ratio 4.5) absorption systems for simultaneous cooling and heating. The interactions of operating temperatures have been illustrated graphically.

水卡罗罗吸收式热泵系统的热力学设计数据。第三部分:同时冷却和加热
吉布斯相律和工作对的热力学性质限制了工作温度的选择。对于任何温度组合,吸收器和发生器中的浓度以及因此的流量比都是固定的。对于任何特定的工作副,性能系数都与流量比有关。对于同时冷却和加热的水-卡罗尔(溴化锂-乙二醇,比例为4.5)吸收系统,给出了工作温度和浓度的可能组合表,包括流动曲线、卡诺性能系数和基于焓的性能系数。工作温度的相互作用已用图形说明。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信