{"title":"Are active dwell positions always necessary in the ring/ovoids channel of the cervical applicator in the intracavitary-interstitial brachytherapy of cervical cancer?","authors":"Georgina Fröhlich,&nbsp;Júlia Vízkeleti,&nbsp;Anhhong Nhung Nguyen,&nbsp;Csaba Polgár,&nbsp;Zoltán Takácsi-Nagy,&nbsp;Tibor Major","doi":"10.5114/jcb.2023.124399","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare dosimetric parameters of brachytherapy (BT) treatment plans made with or without active source positions of the ring/ovoid (R/O) applicator in locally advanced cervical cancer patients.</p><p><strong>Material and methods: </strong>Sixty patients with cervical cancer without vaginal involvement were selected for the study, who received intra-cavitary/interstitial BT. For each patient, two plans with and without active source dwell positions in R/O were created, using the same dose-volume constraints. EQD<sub>2</sub> total doses from external beam and BT of target volumes and organs at risk (OARs) between the competing plans were compared.</p><p><strong>Results: </strong>There was no significant difference in the dose of high-risk clinical target volume (HR-CTV) and gross tumor volume (GTV) between the plans with inactive vs. active R/O. The mean D<sub>98</sub> of intermediate-risk clinical target volume (IR-CTV) was significantly lower with inactive R/O; however, the GEC-ESTRO (EMBRACE II study) and ABS criteria were fulfilled in 96% in both plans. There was no difference in dose homogeneity, but conformity of the plans with inactive R/O was higher. Doses to all OARs were significantly lower in plans without R/O activation. While all the plans without R/O activation fulfilled the recommended dose criteria for OARs, it was less achievable with R/O activation.</p><p><strong>Conclusions: </strong>Inactivation of R/O applicator results in similar dose coverage of the target volumes with lower doses to all OARs, as activation of R/O in cervix cancer patients when HR-CTV does not extend to R/O applicator. The use of active source positions in R/O shows worse performance regarding the fulfilment of the recommended criteria for OARs.</p>","PeriodicalId":51305,"journal":{"name":"Journal of Contemporary Brachytherapy","volume":"15 1","pages":"48-56"},"PeriodicalIF":1.1000,"publicationDate":"2023-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/39/f4/JCB-15-49992.PMC10034727.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Contemporary Brachytherapy","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5114/jcb.2023.124399","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To compare dosimetric parameters of brachytherapy (BT) treatment plans made with or without active source positions of the ring/ovoid (R/O) applicator in locally advanced cervical cancer patients.

Material and methods: Sixty patients with cervical cancer without vaginal involvement were selected for the study, who received intra-cavitary/interstitial BT. For each patient, two plans with and without active source dwell positions in R/O were created, using the same dose-volume constraints. EQD2 total doses from external beam and BT of target volumes and organs at risk (OARs) between the competing plans were compared.

Results: There was no significant difference in the dose of high-risk clinical target volume (HR-CTV) and gross tumor volume (GTV) between the plans with inactive vs. active R/O. The mean D98 of intermediate-risk clinical target volume (IR-CTV) was significantly lower with inactive R/O; however, the GEC-ESTRO (EMBRACE II study) and ABS criteria were fulfilled in 96% in both plans. There was no difference in dose homogeneity, but conformity of the plans with inactive R/O was higher. Doses to all OARs were significantly lower in plans without R/O activation. While all the plans without R/O activation fulfilled the recommended dose criteria for OARs, it was less achievable with R/O activation.

Conclusions: Inactivation of R/O applicator results in similar dose coverage of the target volumes with lower doses to all OARs, as activation of R/O in cervix cancer patients when HR-CTV does not extend to R/O applicator. The use of active source positions in R/O shows worse performance regarding the fulfilment of the recommended criteria for OARs.

Abstract Image

Abstract Image

在宫颈癌腔间质内近距离放射治疗中,宫颈涂抹器的环形/卵形通道中是否总是需要主动驻留位置?
目的:比较采用或不采用环形/卵形(R/O)应用器源位置的近距离放疗(BT)治疗方案在局部晚期宫颈癌患者中的剂量学参数。材料和方法:本研究选择60例未累及阴道的宫颈癌患者,接受腔内/间质BT治疗。在相同的剂量-体积约束下,为每位患者创建两种方案,在R/O中有和没有活性源驻留位置。比较了不同计划间靶体积和危险器官(OARs)外束和BT的EQD2总剂量。结果:R/O不活跃方案与R/O活跃方案的高危临床靶体积(HR-CTV)和总肿瘤体积(GTV)剂量差异无统计学意义。不活跃R/O组中危临床靶体积(IR-CTV)平均D98显著降低;然而,两种方案的GEC-ESTRO (EMBRACE II研究)和ABS标准均达到96%。剂量均匀性无差异,但非活性R/O方案的符合性较高。在没有R/O激活的计划中,所有桨的剂量都显著降低。虽然没有R/O激活的所有计划都达到了OARs的推荐剂量标准,但R/O激活的计划则不太可能实现。结论:R/O涂抹器失活导致所有OARs在较低剂量下对靶体积的剂量覆盖相似,当HR-CTV未扩展到R/O涂抹器时,宫颈癌患者的R/O激活。在R/O中使用主动源位置表明,在实现桨的建议标准方面,性能较差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Contemporary Brachytherapy
Journal of Contemporary Brachytherapy ONCOLOGY-RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
CiteScore
2.40
自引率
14.30%
发文量
54
审稿时长
16 weeks
期刊介绍: The “Journal of Contemporary Brachytherapy” is an international and multidisciplinary journal that will publish papers of original research as well as reviews of articles. Main subjects of the journal include: clinical brachytherapy, combined modality treatment, advances in radiobiology, hyperthermia and tumour biology, as well as physical aspects relevant to brachytherapy, particularly in the field of imaging, dosimetry and radiation therapy planning. Original contributions will include experimental studies of combined modality treatment, tumor sensitization and normal tissue protection, molecular radiation biology, and clinical investigations of cancer treatment in brachytherapy. Another field of interest will be the educational part of the journal.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信