Abandoned coal mine tunnels: Future heating/power supply centers

Luo Pingjia , Chen Ning
{"title":"Abandoned coal mine tunnels: Future heating/power supply centers","authors":"Luo Pingjia ,&nbsp;Chen Ning","doi":"10.1016/j.mstc.2011.10.011","DOIUrl":null,"url":null,"abstract":"<div><p>We have studied three plans for re-use of the abandoned mine roadway tunnels as an energy center. These are the thermostat plan, the thermal accumulator plan, and the CAES plan. Calculations show that the thermostat plan can provide over 15,000<!--> <!-->m<sup>2</sup> of building air-conditioning/heating load for each kilometer of roadway, but electric power is needed to run the system. Numerical research proved that the accumulation of hot water in the roadway for seasonal heating purposes (a temperature swing from 90 to 54<!--> <!-->°C) is a viable possibility. The CAES plan proposes using the discarded coal mine tunnel as a peaking power station with an energy storage density over 7000<!--> <!-->kJ/m<sup>3</sup>. It can be concluded that presently abandoned coal mines could be reformed into future energy centers for a city.</p></div>","PeriodicalId":100930,"journal":{"name":"Mining Science and Technology (China)","volume":"21 5","pages":"Pages 637-640"},"PeriodicalIF":0.0000,"publicationDate":"2011-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.mstc.2011.10.011","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Mining Science and Technology (China)","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1674526411001402","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

Abstract

We have studied three plans for re-use of the abandoned mine roadway tunnels as an energy center. These are the thermostat plan, the thermal accumulator plan, and the CAES plan. Calculations show that the thermostat plan can provide over 15,000 m2 of building air-conditioning/heating load for each kilometer of roadway, but electric power is needed to run the system. Numerical research proved that the accumulation of hot water in the roadway for seasonal heating purposes (a temperature swing from 90 to 54 °C) is a viable possibility. The CAES plan proposes using the discarded coal mine tunnel as a peaking power station with an energy storage density over 7000 kJ/m3. It can be concluded that presently abandoned coal mines could be reformed into future energy centers for a city.

废弃煤矿隧道:未来供热/供电中心
研究了三种废弃矿山巷道作为能源中心的再利用方案。这些是恒温器计划,蓄热器计划,和CAES计划。计算表明,恒温器方案每公里道路可提供15000平方米以上的建筑空调/供暖负荷,但系统运行需要电力。数值研究证明,在巷道中积累热水用于季节性供暖(温度从90°C变化到54°C)是可行的。CAES方案建议将废弃煤矿隧道作为蓄能密度超过7000 kJ/m3的调峰电站。可以得出结论,目前废弃的煤矿可以改造成未来城市的能源中心。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信