{"title":"Coronary stent failure: role of a blended approach with drug-coated balloons for complex lesions.","authors":"Bernardo Cortese, Erick Sanchez-Jimenez, Leontin Lazar","doi":"10.23736/S2724-5683.22.06172-5","DOIUrl":null,"url":null,"abstract":"<p><p>The management of coronary artery disease by means of percutaneous approach have been focused initially to overcome the recoil and acute occlusion after vessel ballooning; therefore, to develop and improve metallic stent platforms, and later drug-eluting technologies. Contemporarily, the necessity emerged to optimize interventional procedures using functional physiologic tests and intravascular imaging guidance, but still stent failures, especially in the complex lesion setting, continue to be not negligible. This comprehensive review is focused on the technology of drug-coated balloons as a tool to treat coronary artery disease without the need for metal implantation but still eluting antirestenotic drugs such as paclitaxel or sirolimus. We delve into these technologies, the drugs, the technical aspects of the deployment and the most updated evidence also proposing a dedicated interventional algorithm. There is solid data to support the use of drug-coated balloons in patients with in-stent restenosis and de-novo small coronary artery disease but also new evidence with promising results from recent studies indicate the feasibility of this approach in complex coronary interventions, bifurcation lesions and larger coronary vessels. In this state-of-the-art review, we also propose a blended approach based on the combination of drug-eluting stents and drug-coated balloons, keeping in mind the necessity to reduce the total stent length in order to reduce the long-term risk of complications.</p>","PeriodicalId":18668,"journal":{"name":"Minerva cardiology and angiology","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Minerva cardiology and angiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.23736/S2724-5683.22.06172-5","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/3/20 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
The management of coronary artery disease by means of percutaneous approach have been focused initially to overcome the recoil and acute occlusion after vessel ballooning; therefore, to develop and improve metallic stent platforms, and later drug-eluting technologies. Contemporarily, the necessity emerged to optimize interventional procedures using functional physiologic tests and intravascular imaging guidance, but still stent failures, especially in the complex lesion setting, continue to be not negligible. This comprehensive review is focused on the technology of drug-coated balloons as a tool to treat coronary artery disease without the need for metal implantation but still eluting antirestenotic drugs such as paclitaxel or sirolimus. We delve into these technologies, the drugs, the technical aspects of the deployment and the most updated evidence also proposing a dedicated interventional algorithm. There is solid data to support the use of drug-coated balloons in patients with in-stent restenosis and de-novo small coronary artery disease but also new evidence with promising results from recent studies indicate the feasibility of this approach in complex coronary interventions, bifurcation lesions and larger coronary vessels. In this state-of-the-art review, we also propose a blended approach based on the combination of drug-eluting stents and drug-coated balloons, keeping in mind the necessity to reduce the total stent length in order to reduce the long-term risk of complications.