Coronary stent failure: role of a blended approach with drug-coated balloons for complex lesions.

IF 1.4 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
Minerva cardiology and angiology Pub Date : 2024-06-01 Epub Date: 2023-03-20 DOI:10.23736/S2724-5683.22.06172-5
Bernardo Cortese, Erick Sanchez-Jimenez, Leontin Lazar
{"title":"Coronary stent failure: role of a blended approach with drug-coated balloons for complex lesions.","authors":"Bernardo Cortese, Erick Sanchez-Jimenez, Leontin Lazar","doi":"10.23736/S2724-5683.22.06172-5","DOIUrl":null,"url":null,"abstract":"<p><p>The management of coronary artery disease by means of percutaneous approach have been focused initially to overcome the recoil and acute occlusion after vessel ballooning; therefore, to develop and improve metallic stent platforms, and later drug-eluting technologies. Contemporarily, the necessity emerged to optimize interventional procedures using functional physiologic tests and intravascular imaging guidance, but still stent failures, especially in the complex lesion setting, continue to be not negligible. This comprehensive review is focused on the technology of drug-coated balloons as a tool to treat coronary artery disease without the need for metal implantation but still eluting antirestenotic drugs such as paclitaxel or sirolimus. We delve into these technologies, the drugs, the technical aspects of the deployment and the most updated evidence also proposing a dedicated interventional algorithm. There is solid data to support the use of drug-coated balloons in patients with in-stent restenosis and de-novo small coronary artery disease but also new evidence with promising results from recent studies indicate the feasibility of this approach in complex coronary interventions, bifurcation lesions and larger coronary vessels. In this state-of-the-art review, we also propose a blended approach based on the combination of drug-eluting stents and drug-coated balloons, keeping in mind the necessity to reduce the total stent length in order to reduce the long-term risk of complications.</p>","PeriodicalId":18668,"journal":{"name":"Minerva cardiology and angiology","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Minerva cardiology and angiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.23736/S2724-5683.22.06172-5","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/3/20 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

The management of coronary artery disease by means of percutaneous approach have been focused initially to overcome the recoil and acute occlusion after vessel ballooning; therefore, to develop and improve metallic stent platforms, and later drug-eluting technologies. Contemporarily, the necessity emerged to optimize interventional procedures using functional physiologic tests and intravascular imaging guidance, but still stent failures, especially in the complex lesion setting, continue to be not negligible. This comprehensive review is focused on the technology of drug-coated balloons as a tool to treat coronary artery disease without the need for metal implantation but still eluting antirestenotic drugs such as paclitaxel or sirolimus. We delve into these technologies, the drugs, the technical aspects of the deployment and the most updated evidence also proposing a dedicated interventional algorithm. There is solid data to support the use of drug-coated balloons in patients with in-stent restenosis and de-novo small coronary artery disease but also new evidence with promising results from recent studies indicate the feasibility of this approach in complex coronary interventions, bifurcation lesions and larger coronary vessels. In this state-of-the-art review, we also propose a blended approach based on the combination of drug-eluting stents and drug-coated balloons, keeping in mind the necessity to reduce the total stent length in order to reduce the long-term risk of complications.

冠状动脉支架失败:使用药物涂层球囊治疗复杂病变的混合方法的作用。
通过经皮方法治疗冠状动脉疾病最初的重点是克服血管球囊扩张后的反冲和急性闭塞,因此开发和改进了金属支架平台,后来又开发了药物洗脱技术。与此同时,利用功能生理测试和血管内成像引导来优化介入手术的必要性也随之出现,但支架失败的情况仍然不容忽视,尤其是在复杂病变的情况下。本综述重点介绍药物涂层球囊技术,该技术是一种无需植入金属但仍能洗脱紫杉醇或西罗莫司等抗支架药物的冠状动脉疾病治疗工具。我们将深入探讨这些技术、药物、部署的技术方面以及最新的证据,并提出一种专门的介入算法。有确凿的数据支持将药物涂层球囊用于支架内再狭窄和新发冠状动脉小病变患者,但最近的研究也提供了新的证据,表明这种方法在复杂冠状动脉介入、分叉病变和较大冠状动脉血管中的可行性。在这篇最新综述中,我们还提出了一种基于药物洗脱支架和药物涂层球囊组合的混合方法,同时考虑到必须减少支架总长度,以降低并发症的长期风险。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Minerva cardiology and angiology
Minerva cardiology and angiology CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
2.60
自引率
18.80%
发文量
118
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信